SearcharxivSearch

arXiv subjects

R. Wallny

Publications and source records attributed to R. Wallny.

10 recordsLinked to original sources

Characterization of irradiated RD53A pixel modules with passive CMOS sensors

We are investigating the feasibility of using CMOS foundries to fabricate silicon detectors, both for pixels and for large-area strip sensors. The availability of multi-layer routing will provide the freedom to optimize the sensor geometry and the performance, with biasing structures in poly-silicon layers and MIM-capacitors allowing for AC coupling. A prototyping production of strip test-structures and RD53A compatible pixel sensors was recently completed at LFoundry in a 150$\,$nm CMOS process. This paper will focus on the characterization of irradiated and non-irradiated pixel modules, composed by a CMOS passive sensor interconnected to a RD53A chip. The sensors are designed with a pixel cell of $25\times100\,\mu \mathrm{m}^2$ in case of DC coupled devices and $50\times50\,\mu \mathrm{m}^2$ for the AC coupled ones. Their performance in terms of charge collection, position resolution, and hit efficiency was studied with measurements performed in the laboratory and with beam tests. The RD53A modules with LFoundry silicon sensors were irradiated to fluences up to $1.0\times10^{16}\,\frac{\mathrm{n}_\mathrm{eq}}{\mathrm{cm}^2}$.

physics.ins-det

Technical design of the phase I Mu3e experiment

The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.

physics.ins-det

Charting the European Course to the High-Energy Frontier

We review the capabilities of two projects that have been proposed as the next major European facility, for consideration in the upcoming update of the European Strategy for Particle Physics: CLIC and FCC. We focus on their physics potentials and emphasise the key differences between the linear or circular approaches. We stress the uniqueness of the FCC-ee programme for precision electroweak physics at the $Z$ peak and the $WW$ threshold, as well as its unequalled statistics for Higgs physics and high accuracy for observing possible new phenomena in Higgs and $Z$ decays, whereas CLIC and FCC-ee offer similar capabilities near the $t \overline t$ threshold. Whilst CLIC offers the possibility of energy upgrades to 1500 and 3000 GeV, FCC-ee paves the way for FCC-hh. The latter offers unique capabilities for making direct or indirect discoveries in a new energy range, and has the highest sensitivity to the self-couplings of the Higgs boson and any anomalous couplings. We consider the FCC programme to be the best option to maintain Europe's place at the high-energy frontier during the coming decades.

hep-ex

Three-dimensional charge transport mapping by two-photon absorption edge transient-current technique in synthetic single-crystalline diamond

We demonstrate the application of two-photon absorption transient current technique to wide bandgap semiconductors. We utilize it to probe charge transport properties of single-crystal Chemical Vapor Deposition (scCVD) diamond. The charge carriers, inside the scCVD diamond sample, are excited by a femtosecond laser through simultaneous absorption of two photons. Due to the nature of two-photon absorption, the generation of charge carriers is confined in space (3-D) around the focal point of the laser. Such localized charge injection allows to probe the charge transport properties of the semiconductor bulk with a fine-grained 3-D resolution. Exploiting spatial confinement of the generated charge, the electrical field of the diamond bulk was mapped at different depths and compared to an X-ray diffraction topograph of the sample. Measurements utilizing this method provide a unique way of exploring spatial variations of charge transport properties in transparent wide-bandgap semiconductors.

physics.ins-det

Proof-of-principle of a new geometry for sampling calorimetry using inorganic scintillator plates

A novel geometry for a sampling calorimeter employing inorganic scintillators as an active medium is presented. To overcome the mechanical challenges of construction, an innovative light collection geometry has been pioneered, that minimises the complexity of construction. First test results are presented, demonstrating a successful signal extraction. The geometry consists of a sampling calorimeter with passive absorber layers interleaved with layers of an active medium made of inorganic scintillating crystals. Wavelength-shifting (WLS) fibres run along the four long, chamfered edges of the stack, transporting the light to photodetectors at the rear. To maximise the amount of scintillation light reaching the WLS fibres, the scintillator chamfers are depolished. It is shown herein that this concept is working for cerium fluoride (CeF$_3$) as a scintillator. Coupled to it, several different types of materials have been tested as WLS medium. In particular, materials that might be sufficiently resistant to the High-Luminosity Large Hadron Collider radiation environment, such as cerium-doped Lutetium-Yttrium Orthosilicate (LYSO) and cerium-doped quartz, are compared to conventional plastic WLS fibres. Finally, an outlook is presented on the possible optimisation of the different components, and the construction and commissioning of a full calorimeter cell prototype is presented.

physics.ins-det

Operational experience, improvements, and performance of the CDF Run II silicon vertex detector

The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acceptance. To realize these goals, in 2001 CDF installed eight layers of silicon microstrip detectors around its interaction region. These detectors were designed for 2--5 years of operation, radiation doses up to 2 Mrad (0.02 Gy), and were expected to be replaced in 2004. The sensors were not replaced, and the Tevatron run was extended for several years beyond its design, exposing the sensors and electronics to much higher radiation doses than anticipated. In this paper we describe the operational challenges encountered over the past 10 years of running the CDF silicon detectors, the preventive measures undertaken, and the improvements made along the way to ensure their optimal performance for collecting high quality physics data. In addition, we describe the quantities and methods used to monitor radiation damage in the sensors for optimal performance and summarize the detector performance quantities important to CDF's physics program, including vertex resolution, heavy flavor tagging, and silicon vertex trigger performance.

physics.ins-det

Results on damage induced by high-energy protons in LYSO calorimeter crystals

Lutetium-Yttrium Orthosilicate doped with Cerium (LYSO:Ce), as a bright scintillating crystal, is a candidate for calorimetry applications in strong ionizing-radiation fields and large high-energy hadron fluences as are expected at the CERN Large Hadron Collider after the planned High-Luminosity upgrade. There, proton-proton collisions will produce fast hadron fluences up to ~5E14/cm^2 in the large-rapidity regions of the calorimeters. The performance of LYSO:Ce has been investigated, after exposure to different fluences of 24 GeV/c protons. Measured changes in optical transmission as a function of proton fluence are presented, and the evolution over time due to spontaneous recovery at room temperature is studied. The activation of materials will also be an issue in the described environment. Studies of the ambient dose induced by LYSO and its evolution with time, in comparison with other scintillating crystals, have also been performed through measurements and FLUKA simulations.

physics.ins-det

Research Proposal for an Experiment to Search for the Decay μ -> eee

We propose an experiment (Mu3e) to search for the lepton flavour violating decay mu+ -> e+e-e+. We aim for an ultimate sensitivity of one in 10^16 mu-decays, four orders of magnitude better than previous searches. This sensitivity is made possible by exploiting modern silicon pixel detectors providing high spatial resolution and hodoscopes using scintillating fibres and tiles providing precise timing information at high particle rates.

physics.ins-det

Performance studies of scintillating ceramic samples exposed to ionizing radiation

Scintillating ceramics are a promising, new development for various applications in science and industry. Their application in calorimetry for particle physics experiments is expected to involve an exposure to high levels of ionizing radiation. In this paper, changes in performance have been measured for scintillating ceramic samples of different composition after exposure to penetrating ionizing radiation up to a dose of 38 kGy.

physics.ins-det

A visualization of the damage in Lead Tungstate calorimeter crystals after exposure to high-energy hadrons

The anticipated performance of calorimeter crystals in the environment expected after the planned High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN has to be well understood, before informed decisions can be made on the need for detector upgrades. Throughout the years of running at the HL-LHC, the detectors will be exposed to considerable fluences of fast hadrons, that have been shown to cause cumulative transparency losses in Lead Tungstate scintillating crystals. In this study, we present direct evidence of the main underlying damage mechanism. Results are shown from a test that yields a direct insight into the nature of the hadron-specific damage in Lead Tungstate calorimeter crystals exposed to 24 GeV/c protons.

physics.ins-det