SearcharxivSearch

arXiv subjects

R. Walsh

Publications and source records attributed to R. Walsh.

3 recordsLinked to original sources

Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

physics.ins-det

Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC

The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to the CMS detector, a beam abort is induced. The Fast Beam Conditions Monitor, BCM1F, is a flux counter close to the beam pipe inside the tracker volume. It uses single-crystal CVD diamond sensors, radiation-hard FE electronics, and optical signal transmission to measure the beam halo as well as collision products bunch by bunch. The system has been operational during the initiatory runs of LHC in September 2008. It works reliably since the restart in 2009 and is invaluable to CMS for everyday LHC operation. A characterisation of the system on the basis of data collected during LHC operation is presented.

physics.ins-det

Bounds on the electromagnetic interactions of excited spin-3/2 leptons

We discuss possible deviations from QED produced by a virtual excited spin-3/2 lepton in the reaction $e^+e^- \longrightarrow 2γ$. Data recorded by the OPAL Collaboration at a c.m. energy $\sqrt{s} = 183 GeV$ are used to establish bounds on the nonstandard-lepton mass and coupling strengths.

hep-ph