SearcharxivSearch

arXiv subjects

R. Wheadon

Publications and source records attributed to R. Wheadon.

At least 19 recordsLinked to original sources

Radiation tolerance tests on key components of the ePIC-dRICH readout card

The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5x5x12 cm^3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.

physics.ins-det

First results on monolithic CMOS detector with internal gain

In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $\mu$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $\mu$m $\times$ 250 $\mu$m and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from $C(V)$ measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).

physics.ins-det

Data acquisition system for a 146-channel counter of protons in particle therapy

A prototype of proton counter was developed by the University and the National Institute for Nuclear Physics of Torino to be used as online fluence beam monitor in particle therapy. The single particle identification approach aims at increasing the sensitivity and readout speed with respect to the state-of-the-art gas ionization chambers. The sensitive area is 2,7 x 2,7 cm^2 to cover the clinical beam cross section characterized by a full width at half maximum of about 1 cm at the isocenter. The sensor is a thin Low Gain Avalanche Diode segmented in 146 strips with 180 micrometer pitch and with 50 micrometer active thickness, designed and produced by the Fondazione Bruno Kessler (Trento, Italy). The frontend readout to identify the single proton signal provided by each strip is based on a 24channel custom ASICs, named ABACUS, optimized to discriminate the signal pulses in a wide charge range (3-150 fC) with a maximum dead-time of 10 ns. With these specifications, at the maximum fluence rate of 10^8 p/(cm^2s) in the clinical energy range (60-230 MeV) and considering the silicon strips described above, a maximum pileup counting inefficiency less than 1 percent is achieved. A frontend board housing 6 ABACUS chips to readout the 146 strips was developed, the digital outputs being sent to 3 FPGAs (Kintex7) for the counting. A LabVIEW program implements the interface with the FPGAs, displays online the counting rate from each strip and stores the data for offline analysis.

physics.ins-det

The CGEM-IT readout chain

An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.

physics.ins-det

NURE: An ERC project to study nuclear reactions for neutrinoless double beta decay

Neutrinoless double beta decay (0ν\b{eta}\b{eta}) is considered the best potential resource to determine the absolute neutrino mass scale. Moreover, if observed, it will signal that the total lepton number is not conserved and neutrinos are their own anti-particles. Presently, this physics case is one of the most important research beyond Standard Model and might guide the way towards a Grand Unified Theory of fundamental interactions. Since the \b{eta}\b{eta} decay process involves nuclei, its analysis necessarily implies nuclear structure issues. The 0ν\b{eta}\b{eta} decay rate can be expressed as a product of independent factors: the phase-space factors, the nuclear matrix elements (NME) and a function of the masses of the neutrino species. Thus the knowledge of the NME can give information on the neutrino mass scale, if the 0ν\b{eta}\b{eta} decay rate is measured. In the NURE project, supported by a Starting Grant of the European Research Council, nuclear reactions of double charge-exchange (DCE) will be used as a tool to extract information on the \b{eta}\b{eta} NME. In DCE reactions and \b{eta}\b{eta} decay, the initial and final nuclear states are the same and the transition operators have similar structure. Thus the measurement of the DCE absolute crosssections can give crucial information on \b{eta}\b{eta} matrix elements.

nucl-ex

Innovative design and construction technique for the Cylindrical GEM detector for the BESIII experiment

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the particles and to exploit the its properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allow to create very large area GEM foils (up to 50x100 cm2) and thanks to the small thickness of these foil is it possible to shape it to the desired form: a Cylindrical Gas Electron Multiplier (CGEM) is then proposed. The innovative construction technique based on Rohacell, a PMI foam, will give solidity to cathode and anode with a very low impact on material budget. The entire detector is sustained by permaglass rings glued at the edges. These rings are use to assembly the CGEM together with a dedicated Vertical Insertion System and moreover there is placed the On-Detector electronic. The anode has been improved w.r.t. the state of the art through a jagged readout that minimize the inter-strip capacitance. The mechanical challenge of this detector requires a precision of the entire geometry within few hundreds of microns in the whole area. In this presentation will be presented an overview of the construction technique and the validation of this technique through the realization of a CGEM and its first tests. These activities are performed within the framework of the BESIIICGEM Project (645664), funded by the European Commission in the action H2020-RISE-MSCA-2014.

physics.ins-det

Performance of the micro-TPC Reconstruction for GEM Detectors at High Rate

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors, as drift chambers and microstrips, reducing the discharge rate and increasing the radiation tolerance. Among these, one of the most commonly used is the Gas Electron Multiplier. Commonly deployed as fast timing detectors and triggers, due to their fast response, high rate capability and high radiation hardness, they can also be used as trackers. The center of gravity readout technique allows to overcome the limit of the digital pads, whose spatial resolution is constrained by the pitch size. The presence of a high external magnetic field can distort the electronic cloud and affect the spatial resolution. The micro-TPC reconstruction method allows to reconstruct the three dimensional particle position as in a traditional Time Projection Chamber, but within a drift gap of a few millimeters. This method brings these detectors into a new perspective for what concerns the spatial resolution in strong magnetic field. In this report, the basis of this new technique will be shown and it will be compared to the traditional center of gravity. The results of a series of test beam performed with 10 x 10 cm2 planar prototypes in magnetic field will also be presented. This is one of the first implementations of this technique for GEM detectors in magnetic field and allows to reach unprecedented performance for gas detectors, up to a limit of 120 micron at 1T, one of the world's best results for MPGDs in strong magnetic field. The micro-TPC reconstruction has been recently tested at very high rates in a test beam at the MAMI facility; preliminary results of the test will be presented.

physics.ins-det

Test beam results of a Cylindrical GEM detector for the BESIII experiment

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged particles and to exploit their properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allows to create very large area GEM foils (up to 50x100 $\mathrm{cm}^2$) and thanks to the small thickness of these foils is it possible to shape it to the desired form: a Cylindrical Gas Electron Multiplier (CGEM) is then proposed. The innovative construction technique based on Rohacell, a PMI foam, will give solidity to cathode and anode with a very low impact on material budget. The entire detector is sustained by Permaglass rings glued at the edges. These rings are used to assembly the CGEM, together with a dedicated Vertical Insertion System and moreover they host the On-Detector electronic. The anode has been improved w.r.t. the state of the art through a jagged readout that minimize the inter-strip capacitance. The mechanical challenge of this detector requires a precision of the entire geometry within few hundreds of microns in the whole area. In this contribution an overview of the construction technique, the validation of this technique through the realization of a CGEM, and its first tests will be presented. These activities are performed within the framework of the BESIIICGEM Project (645664), funded by the European Commission in the action H2020-RISE-MSCA-2014.

physics.ins-det

The new cylindrical GEM inner tracker of BESIII

The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a 1T magnetic field. The simultaneous measurement of both the deposited charge and the signal time will permit to use a combination of two algorithms to evaluate the spatial position of the charged tracks inside the CGEM-IT: the charge centroid and the micro time projection chamber modes. They are complementary and can cope with the asymmetry of the electron avalanche when running in magnetic field and with non-orthogonal incident tracks. To evaluate the behavior under different working settings, both planar chambers and the first cylindrical prototype have been tested during various test beams at CERN with 150 GeV/c muons and pions. This paper reports the results obtained with the two reconstruction methods and a comparison between the planar and cylindrical chambers.

physics.ins-det

Test beam results with prototypes for the new Cylindrical GEM Inner Tracker of the BESIII experiment

A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150 GeV/c momentum, to evaluate the efficiency and resolution under different working conditions. The obtained efficiency was in the 96 - 98% range. Two complementary algorithms for the position determination were developed: the charge centroid and the micro-TPC methods. With the former, resolutions <100 micron and <200 micron were achieved without and with magnetic field, respectively. The micro-TPC improved these results. By the end of 2016, the first cylindrical prototype was tested on the same beam line. It showed optimal stability under different settings. The comparison of its performance with respect to the planar chambers is ongoing. Here, the results of the planar prototype tests will be addressed.

physics.ins-det

The Cylindrical GEM Inner Tracker of the BESIII experiment: prototype test beam results

A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is taking data at the e+e- collider BEPCII in Beijing (China) and the GEM tracker will be installed in 2018. Tests on the performances of triple GEMs in strong magnetic field have been run by means of the muon beam available in the H4 line of SPS (CERN) with both planar chambers and the first cylindrical prototype. Efficiencies and resolutions have been evaluated using different gains, gas mixtures, with and without magnetic field. The obtained efficiency is 97-98% on single coordinate view, in many operational arrangements. The spatial resolution for planar GEMs has been evaluated with two different algorithms for the position determination: the charge centroid and the micro time projection chamber (mu-TPC) methods. The two modes are complementary and are able to cope with the asymmetry of the electron avalanche when running in magnetic field, and with non-orthogonal incident tracks. With the charge centroid, a resolution lower than 100 micron has been reached without magnetic field and lower than 200 micron with a magnetic field up to 1 T. The mu-TPC mode showed to be able to improve those results. In the first beam test with the cylindrical prototype, the detector had a very good stability under different voltage configurations and particle intensities. The resolution evaluation is in progress.

physics.ins-det

A custom readout electronics for the BESIII CGEM detector

For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 um while loosening the pitch strip to 650 um, which allows to reduce the total number of channels to about 10 000. The channels are readout by 160 dedicated integrated 64-channel front-end ASICs, providing a time and charge measurement and featuring a fully-digital output. The energy measurement is extracted either from the time-over-threshold (ToT) or the 10-bit digitisation of the peak amplitude of the signal. The time of the event is generated by quad-buffered low-power TDCs, allowing for rates in excess of 60 kHz per channel. The TDCs are based on analogue interpolation techniques and produce a time stamp (or two, if working in ToT mode) of the event with a time resolution better than 50 ps. The front-end noise, based on a CSA and CR-RC2 shapers, dominate the channel intrinsic time jitter, which is less than 5 ns r.m.s.. The time information of the hit can be used to reconstruct the track path, operating the detector as a small TPC and hence improving the position resolution when the distribution of the cloud, due to large incident angle or magnetic field, is very broad. Event data is collected by an off-detector motherboard, where each GEM-ROC readout card handles 4 ASIC carrier PCBs (512 channels). Configuration upload and data readout between the off-detector electronics and the VME-based data collector cards are managed by bi-directional fibre optical links.

physics.ins-det

$Σ^- p$ emission rates in $K^-$ absorptions at rest on $^6$Li, $^7$Li, $^{9}$Be, $^{13}$C and $^{16}$O

An experimental study of the $K^-_{stop}A\rightarrow Σ^- p A'$ reaction on $A=^6$Li, $^7$Li, $^9$Be, $^{13}$C and $^{16}$O $p$-shell nuclei is presented. The data were collected by the FINUDA spectrometer operating at the DA$Φ$NE $ϕ$-factory (LNF-INFN, Italy). Emission rates for the reaction in the mentioned nuclei are measured and compared with the few existing data. The spectra of several observables are discussed; indications of Quasi-Free absorptions by a $(np)$ pair embedded in the $A$ nucleus can be obtained from the study of the missing mass distributions.

nucl-ex

First observation of the hyper superheavy hydrogen 6ΛH

Three candidate events of the neutron-rich hypernucleus 6ΛH were uniquely identified in the FINUDA experiment at DAΦNE, Frascati, by observing π+ mesons from the (K-stop,π+) production reaction on 6Li targets, in coincidence with π-mesons from 6ΛH \rightarrow 6He+π- weak decay. Details of the experiment and the analysis of its data are reported, leading to an estimate of (2.9\pm2.0)\cdot10-6/K- stop for the 6ΛH production rate times the two-body π- weak decay branching ratio. The 6ΛH binding energy with respect to 5H + Λ was determined jointly from production and decay to be BΛ = (4.0 \pm 1.1) MeV, assuming that 5H is unbound with respect to 3H + 2n by 1.7 MeV. The binding energy determined from production is higher, in each one of the three events, than that determined from decay, with a difference of (0.98 \pm 0.74) MeV here assigned to the 0+g.s. \rightarrow 1+ excitation. The consequences of this assignment to Λ hypernuclear dynamics are briefly discussed.

nucl-ex

Evidence for 6ΛH

Evidence for the neutron-rich hypernucleus 6ΛH is presented from the FINUDA experiment at DAΦNE, Frascati, studying (π+, π-) pairs in coincidence from the K- +6Li \rightarrow 6 H+π+ production reaction followed by 6ΛH \rightarrow 6He + π- weak decay. The production rate of 6ΛH undergoing this two-body π- decay is determined to be (2.9\pm2.0)\cdot10-6/K-. Its binding energy, evaluated jointly from production and decay, is BΛ(6ΛH) = (4.0\pm1.1) MeV with respect to 5H+Λ. A systematic difference of (0.98 \pm 0.74) MeV between BΛ values derived separately from decay and from production is tentatively assigned to the 6ΛH 0+g.s. \rightarrow 1+ excitation.

nucl-ex

The $A(K^-_{stop},π^\pmΣ^\mp)A'$ reaction on p-shell nuclei

This letter is concerned with the study of the $K^-_{stop}A\rightarrow π^\pmΣ^\mp A'$ reaction in p-shell nuclei, i.e., $^{6,7}Li$, $^9Be$, $^{13}C$ and $^{16}O$. The $π^\pmΣ^\mp / K^-_{stop}$ emission rates are reported as a function of $A$. These rates are discussed in comparison with previous findings. The ratio $π^-Σ^+/π^+Σ^-$ in p-shell nuclei is found to depart largely from that on hydrogen, which provides support for large in-medium effects possibly generated by the sub-threshold $Λ(1405)$. The continuum momentum spectra of prompt pions and free sigmas are also discussed as well as the $π^\pmΣ^\mp$ missing mass behavior and the link with the reaction mechanism. The apparatus used for the investigation is the FINUDA spectrometer operating at the DA$Φ$NE $ϕ$-factory (LNF-INFN, Italy).

nucl-ex

Study of some two-body non-mesonic decays of $^4_Λ$He and $^5_Λ$He

The Non-Mesonic (NM) decay of $^4_Λ{\mathrm{He}}$ and $^5_Λ{\mathrm{He}}$ in two-body channels has been studied by the FINUDA Collaboration. Two-body NM decays of hypernuclei are rare and the existing observations and theoretical calculations are scarce. The $^4_Λ{\mathrm{He}}\rightarrow d+d,\; p+t$ decay channels simultaneously observed by FINUDA on several nuclei are compared: the $pt$ channel is the dominant one. The decay yields for the two decay channels are assessed for the first time: they are $(1.37\pm 0.37)\times 10^{-5}/K^-_{stop}$ and $(8.3\pm 1.0)\times 10^{-5}/K^-_{stop}$, respectively. Due to the capability of FINUDA of identifying $^5_Λ{\mathrm{He}}$ hypernuclei, a few $^5_Λ{\mathrm{He}}\rightarrow d+t$ decay events have also been observed. The branching ratio for this decay channel has been measured for the first time: $(3.0\pm 2.3)\times 10^{-3}$.

nucl-ex