SearcharxivSearch

arXiv subjects

Rachel M. Godun

Publications and source records attributed to Rachel M. Godun.

7 recordsLinked to original sources

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

physics.atom-ph

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

$^{171}$Yb$^+$ optical clock with $2.2\times 10^{-18}$ systematic uncertainty and absolute frequency measurements

A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of $2.2\times 10^{-18}$. Furthermore, the absolute frequency of the E3 transition of the $^{171}$Yb$^+$ ion was measured between 2019 and 2023 via a link to International Atomic Time (TAI) and against the local caesium fountain NPL-CsF2. The absolute frequencies were measured with fractional standard uncertainties between $3.7 \times 10^{-16}$ and $1.1 \times 10^{-15}$, and all were in agreement with the 2021 BIPM recommended frequency.

physics.atom-ph

Analysis of atomic-clock data to constrain variations of fundamental constants

We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio, $μ$. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.

physics.atom-ph

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph

Absolute frequency measurement of the $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ optical clock transition in $^{171}$Yb$^+$ with an uncertainty of $4\times 10^{-16}$ using a frequency link to International Atomic Time

The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of $4.0 \times 10 ^{-16}$ is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.

physics.atom-ph

Decoherence as a Probe of Coherent Quantum Dynamics

The effect of decoherence, induced by spontaneous emission, on the dynamics of cold atoms periodically kicked by an optical lattice is experimentally and theoretically studied. Ideally, the mean energy growth is essentially unaffected by weak decoherence, but the resonant momentum distributions are fundamentally altered. It is shown that experiments are inevitably sensitive to certain nontrivial features of these distributions, in a way that explains the puzzle of the observed enhancement of resonances by decoherence [Phys. Rev. Lett. 87, 074102 (2001)]. This clarifies both the nature of the coherent evolution, and the way in which decoherence disrupts it.

quant-ph