Searcharxiv⌕ Search

arXiv subjects

Radhouene Neji

Publications and source records attributed to Radhouene Neji.

3 recordsLinked to original sources

Scan-specific k-space interpolation using deep Koopman autoencoders

Purpose: To develop a scan-specific, interpretable k-space interpolation technique for the reconstruction of accelerated MRI data. Methods: A deep Koopman autoencoder for nonlinear k-space interpolation was developed consisting of an encoder, a linear layer for interpolation and a decoder. The resulting network is implemented using mean square error loss function on k-space neighbourhoods derived from the autocalibration signals (ACS), combining a prediction loss and an autoencoding loss. The approach was compared to GRAPPA and RAKI in 281 retrospectively undersampled brain datasets, using quantitative reconstruction metrics. In a subset of 52 randomly selected images, a clinical reader study compared the proposed approach and RAKI in a forced choice scenario and using a five-point ordinal scoring, assessing sharpness, SNR, aliasing and overall image quality. Additionally, the effect of varying parameters such as the number of autocalibration signals, the contribution of the autoencoding loss, the kernel size, and the latent space dimension for the proposed technique was studied. Results: The proposed approach showed improved quantitative metrics compared to GRAPPA and RAKI. Visually, the method showed higher resilience to noise amplification and improved preservation of sharp details. In the clinical reader study, the proposed approach was preferred overall to RAKI and yielded higher scores than GRAPPA and RAKI. The proposed method showed robustness to parameter variations. Conclusion: Deep Learning based k-space interpolation can be achieved using a Koopman autoencoder for k-space neighbourhoods. Keywords: Parallel imaging, Koopman autoencoder, nonlinear mapping, k-space interpolation, deep learning reconstruction

physics.med-ph↗

3D distortion-free, reduced field of view diffusion-prepared GRE at 3T

Purpose: To develop a 3D distortion-free reduced-FOV diffusion-prepared GRE sequence and demonstrate its in-vivo application for diffusion imaging of the spinal cord in healthy volunteers. Methods: A 3D multi-shot reduced-FOV diffusion-prepared GRE (RFOV-DP-GRE) acquisition is achieved using a slice-selective tip-down pulse in the phase encoding direction in the diffusion preparation, combined with magnitude stabilisers. The efficacy of the developed reduced FOV approach and accuracy of ADC estimates were evaluated in a phantom. In addition, 5 healthy volunteers were enrolled and scanned at 3T using the proposed sequence and a standard spin echo diffusion-weighted single-shot EPI sequence (DW-SS-EPI) for spinal cord imaging. Image quality, perceived SNR and image distortion were assessed by two expert readers and quantitative measurements of apparent SNR were performed. Results: The phantom scan demonstrates the efficacy of the proposed reduced FOV approach. Consistent ADC estimates were measured with RFOV-DP-GRE when compared with DW-SS-EPI. In-vivo, RFOV-DP-GRE demonstrated improved image quality and reduced perceived distortion, while maintaining perceived SNR compared to DW-SS-EPI. Conclusion: 3D Distortion-free diffusion-prepared imaging can be achieved using the proposed sequence

physics.med-ph↗

Motion-corrected and high-resolution anatomically-assisted (MOCHA) reconstruction of arterial spin labelling MRI

A model-based reconstruction framework is proposed for MOtion-Corrected and High-resolution anatomically-Assisted (MOCHA) reconstruction of ASL data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a single high-resolution cerebral blood flow (CBF) map, corrected for rigid motion, point-spread-function (PSF) blurring and partial-volume effect (PVE).Six volunteers were recruited for CBF imaging using PCASL labelling, 2-shot 3D-GRASE sequences and high-resolution T1-weighted MRI. For two volunteers, high-resolution scans with double and triple resolution in the partition direction were additionally collected. Simulations were designed for evaluations against a high-resolution ground-truth CBF map, including a simulated hyper-perfused lesion and hyper/hypo-perfusion abnormalities. MOCHA was compared to standard reconstruction and a 3D linear regression (3DLR) PVE correction method and was further evaluated for acquisitions with reduced control-label pairs and k-space undersampling. MOCHA reconstructions of low-resolution ASL data showed enhanced image quality particularly in the partition direction. In simulations, both MOCHA and 3DLR provided more accurate CBF maps than the standard reconstruction, however MOCHA resulted in the lowest errors and well delineated the abnormalities. MOCHA reconstruction of standard-resolution in-vivo data showed good agreement with higher-resolution scans requiring 4x and 9x longer acquisitions. MOCHA was found to be robust for 4x-accelerated ASL acquisitions, achieved by reduced control-label pairs or k-space undersampling. Conclusion: MOCHA reconstruction reduces PVE by direct reconstruction of CBF maps in the high-resolution space of the corresponding anatomical image, incorporating motion correction and PSF modelling. Following further evaluation, MOCHA should promote the clinical application of ASL.

physics.med-ph↗