SearcharxivSearch

arXiv subjects

Raghu A

Publications and source records attributed to Raghu A.

2 recordsLinked to original sources

Microrheology of non mulberry silk varieties by optical tweezer and video microscopy based techniques

We have carried out a comparative study of the microrheological properties of silk fibroin solutions formed from a variety of silks indigenous to the Indian subcontinent. We present the measured viscoelastic moduli of Tasar silk fibroin solution using both a single and dual optical tweezer at 0.16% and 0.25% (w/v). The bandwidth of the measurements carried out using optical tweezers is extended down to the lower frequency regime by a video microscopy measurement. Further, we have measured the viscoelastic moduli of Eri and Muga varieties of silk fibroin solutions at a higher concentration (1.00% w/v) limiting the tool of measurement to video microscopy, as the reduced optical transparencies of these solutions at higher concentration preclude an optical tweezer based investigation. The choice of a higher concentration of fibroin solution of the latter silk varieties is so as to enable a comparison of the shear moduli obtained from optical methods with their corresponding fibre stiffness obtained from wide angle X-ray scattering data. We report a correlation between the microstructure and microrheological parameters of these silk varieties for the concentration of fibroin solutions studied.

cond-mat.soft

Microrheological Studies of Regenerated Silk Fibroin Solution by Video Microscopy

We have carried out studies on the rheological properties of regenerated silk fibroin (RSF) solution using video microscopy. The degummed silk from the Bombyx mori silkworm was used to prepare RSF solution by dissolving it in calcium nitrate tetrahydrate-methanol solvent. Measurements were carried out by tracking the position of an embedded micron-sized polystyrene bead within the RSF solution through video imaging. The time dependent mean squared displacement (MSD) of the bead in solution and hence, the complex shear modulus of this solution was calculated from the bead's position information. An optical tweezer was used to transport and locate the bead at any desired site within the micro-volume of the sample, to facilitate the subsequent free-bead video analysis. We present here the results of rheological measurements of the silk polymer network in solution over a frequency range, whose upper limit is the frame capture rate of our camera, at full resolution. By examining the distribution of MSD of beads at different locations within the sample volume, we demonstrate that this probe technique enables us to detect local inhomogeneties at micrometer length scales, not detectable either by a rheometer or from diffusing wave spectroscopy.

cond-mat.soft