SearcharxivSearch

arXiv subjects

Ralf Kohlhaas

Publications and source records attributed to Ralf Kohlhaas.

9 recordsLinked to original sources

Developing a Compact SWIR Imaging Spectrometer for CO2 and CH4 Retrieval Using Photonic Crystal Filters

The need for atmospheric measurements with higher spatial and temporal resolution is driving the development of satellites and satellite constellations to complement existing flagship missions. We are developing an instrument concept based on photonic crystal filters with tailored spectral transmission for trace gas retrieval. These filters can be integrated directly with the detector module, enabling a highly compact system architecture. In this work, we present performance simulations for methane and carbon dioxide retrieval in the 1.6 um SWIR band for a medium-resolution global coverage mission with an approximately 250 m spatial resolution and a 150 km swath. We furthermore introduce an improved retrieval algorithm that substantially reduces retrieval bias. These results demonstrate the potential of the proposed architecture for medium-resolution global greenhouse-gas mapping, with retrieval performance comparable to state-of-the-art global mapping missions such as the planned CO2M mission at substantially finer spatial resolution. This measurement approach also inherently compresses the acquired spectral information, reducing the need for high downlink data rates. In the coming year, these filters will be fabricated by NIL Technology, followed by mechanical integration and experimental validation in a breadboard system.

physics.ins-det

Design of efficient high-order immersed metagratings using an evolutionary algorithm

Immersed reflection gratings improve spectral resolving power by enabling diffraction within a high refractive index medium. This principle has been widely adopted to make grating spectrometers more compact. Conventional immersed gratings have blazed profiles which typically show the highest efficiency for one main design wavelength. In addition, the blazed profiles tend to cause significant polarization sensitivity. In this work, we propose an alternative approach for designing an immersed grating composed of sub-wavelength structures, designed to increase diffraction efficiency and reduce polarization dependence. For a theoretical demonstration, a reflective metagrating immersed in silicon is optimized over the short-wave infrared band-3 (SWIR-3, here $2.304~μ$m-$2.405~μ$m), targeting the same diffraction angles as the immersion grating used in the Sentinel-5 Earth observation mission. The structure is optimized using a modified Covariance Matrix Adaptation Evolution Strategy (CMA-ES). The optimized immersed metagrating achieves an average efficiency of (over the SWIR-3 band) $\sim 78\%$, compared to $\sim 62\%$ for the conventional immersed blazed grating, and reduces polarization sensitivity from roughly $\sim 15\%$ to $\sim 5\%$. A manufacturing tolerance analysis is also conducted to evaluate the design's performance under systematic manufacturing errors, which revealed a degradation of $\sim 10\%$ efficiency at feature size errors of $\pm 25{nm}$ and almost negligible effect on the efficiency at $-10{nm}$ and of $\sim 5\%$ at $+10{nm}$.

physics.optics

Selection of Filters for Photonic Crystal Spectrometer Using Domain-Aware Evolutionary Algorithms

This work addresses the critical challenge of optimal filter selection for a novel trace gas measurement device. This device uses photonic crystal filters to retrieve trace gas concentrations affected by photon and read noise. The filter selection directly influences the accuracy and precision of the gas retrieval and, therefore, is a crucial performance driver. We formulate the problem as a stochastic combinatorial optimization problem and develop a simulator modeling gas retrieval with noise. Metaheuristics representing various families of optimizers are used to minimize the retrieval error objective function. We improve the top-performing algorithms using our novel distance-driven extensions, which employ metrics on the space of filter selections. This leads to a new adaptation of the Univariate Marginal Distribution Algorithm (UMDA), called the Univariate Marginal Distribution Algorithm Unified by Probabilistic Logic Sampling driven by Distance (UMDA-U-PLS-Dist), equipped with one of the proposed distance metrics as the most efficient and robust solver among the considered ones. We apply this algorithm to obtain a diverse set of high-performing solutions and analyze them to draw general conclusions about better combinations of transmission profiles. The analysis reveals that filters with large local differences in transmission improve the device performance. Moreover, the obtained top-performing solutions show significant improvement compared to the baseline.

cs.NE

Theoretical performance limitations and filter selection based on Fisher information of a computational photonic crystal spectrometer for trace-gas retrieval

As global climate change severely impacts our world, there is an increasing demand to monitor trace gases with a high spatial resolution and accuracy. At the same time, these instruments need to be compact in order have constellations for short revisit times. Here we present a new spectrometer instrument concept for trace gas detection, where photonic crystals filters replace traditional diffraction based optical elements. In this concept, 2D photonic crystal slabs with unique transmission profiles are bonded on a detector inside a regular telescope. As the instrument flies over the earth, different integrated intensities for each filter are measured for a single ground resolution element with a regular telescope. From this detector data, trace gas concentrations are retrieved. As an initial test case we focused on methane and carbon dioxide retrieval and estimated the performance of such an instrument. We derive the Cramér-Rao lower bound for trace-gas retrieval for such a spectrometer using Fisher information and compare this with the achieved performance. We furthermore set up a framework how to select photonic crystal filters based on maximizing the Fisher information carried by the filters and how to use the Cramér-Rao lower bound to find good filter sets. The retrieval performance of such an instrument is found to be between 0.4% to 0.9% for methane and 0.2% to 0.5% for carbon dioxide detection for a 300x300 m2 ground resolution element and realistic instrument parameters.

physics.optics

Development of a photonic crystal spectrometer for greenhouse gas measurements

The need of atmospheric information with a higher spatial and temporal resolution drives the development of small satellites and satellite constellations to complement satellite flagship missions. Since optical systems are a main contributor to the satellite size, these are the prime candidate for their miniaturization. We present here a novel optical system where the complete spectrometer part of the optical system is compressed in one flat optical element. The element consists of an array of photonic crystals which is directly placed on a detector. The photonic crystals act as optical filters with a tunable spectral transmission response. From the integrated optical signals per filter and the atmosphere model, greenhouse gas concentrations are obtained using computational inversion. We present in this article the instrument concept, the manufacturing and measurement of the photonic crystals, methods for the filter array optimization, and discuss the predicted retrieval performance for the detection of methane and carbon dioxide.

physics.optics

Millimeter-long Fiber Fabry-Perot cavities

We demonstrate fiber Fabry-Perot (FFP) cavities with concave mirrors that can be operated at cavity lengths as large as 1.5mm without significant deterioration of the finesse. This is achieved by using a laser dot machining technique to shape spherical mirrors with ultralow roughness and employing single-mode fibers with large mode area for good mode matching to the cavity. Additionally, in contrast to previous FFPs, these cavities can be used over an octave-spanning frequency range with adequate coatings. We also show directly that shape deviations caused by the fiber's index profile lead to a finesse decrease as observed in earlier attempts to build long FFP cavities, and show a way to overcome this problem.

physics.optics

Feedback control of coherent spin states using weak nondestructive measurements

We consider the decoherence of a pseudo-spin ensemble under collective random rotations, and study, both theoretically and experimentally, how a nondestructive measurement combined with real-time feedback correction can protect the state against such a decoherence process. We theoretically characterize the feedback efficiency with different parameters --- coherence, entropy, fidelity --- and show that a maximum efficiency is reached in the weak measurement regime, when the projection of the state induced by the measurement is negligible. This article presents in detail the experimental results published in [Phys. Rev. Lett. \textbf{110}, 210503 (2013)], where the feedback scheme stabilizes coherent spin states of trapped ultra-cold atoms, and nondestructively probed with a dispersive optical detection. In addition, we study the influence of several parameters, such as atom number and rotation angle, on the performance of the method. We analyze the various decoherence sources limiting the feedback efficiency and propose how to mitigate their effect. The results demonstrate the potential of the method for the real-time coherent control of atom interferometers.

physics.atom-ph

Robust laser frequency stabilization by serrodyne modulation

We report the relative frequency stabilization of a distributed feedback erbium-doped fiber laser on an optical cavity by serrodyne frequency shifting. A correction bandwidth of 2.3 MHz and a dynamic range of 220 MHz are achieved, which leads to a strong robustness against large disturbances up to high frequencies. We demonstrate that serrodyne frequency shifting reaches a higher correction bandwidth and lower relative frequency noise level compared to a standard acousto-optical modulator based scheme. Our results allow to consider promising applications in the absolute frequency stabilization of lasers on optical cavities.

physics.optics

Heterodyne non-demolition measurements on cold atomic samples: towards the preparation of non-classical states for atom interferometry

We report on a novel experiment to generate non-classical atomic states via quantum non-demolition (QND) measurements on cold atomic samples prepared in a high finesse ring cavity. The heterodyne technique developed for the QND detection exhibits an optical shot-noise limited behavior for local oscillator optical power of a few hundred \muW, and a detection bandwidth of several GHz. This detection tool is used in single pass to follow non destructively the internal state evolution of an atomic sample when subjected to Rabi oscillations or a spin-echo interferometric sequence.

quant-ph