SearcharxivSearch

arXiv subjects

Raphael Schneider

Publications and source records attributed to Raphael Schneider.

2 recordsLinked to original sources

Task-Driven Co-Design of Mobile Manipulators

Recent interest in mobile manipulation has resulted in a wide range of new robot designs. A large family of these designs focuses on modular platforms that combine existing mobile bases with static manipulator arms. They combine these modules by mounting the arm in a tabletop configuration. However, the operating workspaces and heights for common mobile manipulation tasks, such as opening articulated objects, significantly differ from tabletop manipulation tasks. As a result, these standard arm mounting configurations can result in kinematics with restricted joint ranges and motions. To address these problems, we present the first Concurrent Design approach for mobile manipulators to optimize key arm-mounting parameters. Our approach directly targets task performance across representative household tasks by training a powerful multitask-capable reinforcement learning policy in an inner loop while optimizing over a distribution of design configurations guided by Bayesian Optimization and HyperBand (BOHB) in an outer loop. This results in novel designs that significantly improve performance across both seen and unseen test tasks, and outperform designs generated by heuristic-based performance indices that are cheaper to evaluate but only weakly correlated with the motions of interest. We evaluate the physical feasibility of the resulting designs and show that they are practical and remain modular, affordable, and compatible with existing commercial components. We open-source the approach and generated designs to facilitate further improvements of these platforms.

cs.RO

Demonstration of Circadian Rhythm in Heart Rate Turbulence using Novel Application of Correlator Functions

Background: It has been difficult to demonstrate circadian rhythm in the two parameters of heart rate turbulence, turbulence onset (TO) and turbulence slope (TS). Objective: To devise a new method for detecting circadian rhythm in noisy data, and apply it to selected Holter recordings from two post-myocardial infarction databases, Cardiac Arrhythmia Suppression Trial (CAST, n=684) and Innovative Stratification of Arrhythmic Risk (ISAR, n=327). Methods: For each patient, TS and TO were calculated for each hour with >4 VPCs. An autocorrelation function Corr(Delta t) = was then calculated, and averaged over all patients. Positive Corr(Delta t) indicates that TS at a given hour and Delta t hours later are similar. TO was treated likewise. Simulations and mathematical analysis showed that circadian rhythm required Corr(Delta t) to have a U-shape consisting of positive values near Delta t=0 and 23, and negative values for intermediate Delta t. Significant deviation of Corr(Delta t) from the correlator function of pure noise was evaluated as a chi-squared value. Results: Circadian patterns were not apparent in hourly averages of TS and TO plotted against clock time, which had large error bars. Their correlator functions, however, produced chi-squared values of ~10 in CAST (both p<0.0001) and ~3 in ISAR (both p<0.0001), indicating presence of circadian rhythmicity. Conclusion: Correlator functions may be a powerful tool for detecting presence of circadian rhythms in noisy data, even with recordings limited to 24 hours.

physics.med-ph