Searcharxiv⌕ Search

arXiv subjects

Rattakorn Kaewuam

Publications and source records attributed to Rattakorn Kaewuam.

5 recordsLinked to original sources

Nuclear spin quenching of the $^2S_{1/2}\rightarrow {^2}F_{7/2} $ electric octupole transition in $^{173}$Yb$^+$

We report the coherent excitation of the highly forbidden $^2S_{1/2} \rightarrow {^2}F_{7/2}$ clock transition in the odd isotope $^{173}\mathrm{Yb}^+$ with nuclear spin $I = 5/2$, and reveal the hyperfine-state-dependent, nuclear spin induced quenching of this transition. The inferred lifetime of the $F_e = 4$ hyperfine state is one order of magnitude shorter than the unperturbed ${^2}F_{7/2}$ clock state of $^{171}\mathrm{Yb}^+$. This reduced lifetime lowers the required optical power for coherent excitation of the clock transition, thereby reducing the AC Stark shift caused by the clock laser. Using a 3-ion Coulomb crystal, we experimentally demonstrate an approximately 20-fold suppression of the AC Stark shift, a critical improvement for the scalability of future multi-ion $\mathrm{Yb}^+$ clocks. Furthermore, we report the $|^2S_{1/2},F_g=3\rangle~\rightarrow~|^2F_{7/2},F_e=6\rangle$ unquenched reference transition frequency as $642.11917656354(43)$ THz, along with the measured hyperfine splitting and calculated quadratic Zeeman sensitivities of the ${^2}F_{7/2}$ clock state. Our results pave the way toward multi-ion optical clocks and quantum computers based on $^{173}\mathrm{Yb}^+$.

physics.atom-ph↗

$^{176}$Lu$^+$ clock comparison at the $10^{-18}$ level via correlation spectroscopy

We experimentally demonstrate agreement between two $^{176}$Lu$^+$ frequency references using correlation spectroscopy. From a comparison at different magnetic fields, we obtain a quadratic Zeeman coefficient of $-4.89264(88)\,\mathrm{Hz/mT^2}$, which gives a corresponding fractional frequency uncertainty contribution of just $2.5\times 10^{-20}$ for comparisons at typical operating fields of 0.1\,mT. A subsequent comparison with both systems at 0.1\,mT, demonstrates a fractional frequency difference of $(-2.0\pm(3.7)_\mathrm{stat}\pm(0.9)_\mathrm{sys})\times10^{-18}$, where `stat' and `sys' indicate statistical and systematic uncertainty, respectively.

quant-ph↗

Precision measurements on the $^{138}$Ba$^+$ $6s^2S_{1/2}-5d^2D_{5/2}$ clock transition

Measurement of the $^{138}$Ba$^+$ ${}^2S_{1/2} - {}^2D_{5/2}$ clock transition frequency and $D_{5/2}$ Landé $g_J$ factor are reported. The clock transition frequency $ν_{\mathrm{Ba}^+}=170\,126\,432\,449\,333.31\pm(0.39)_\mathrm{stat}\pm(0.29)_\mathrm{sys}\,$Hz, is obtained with accuracy limited by the frequency calibration of the maser used as a reference oscillator. The Landé $g_J$-factor for the ${}^2D_{5/2}$ level is determined to be $g_{D}=1.200\,367\,39(24)$, which is a 30-fold improvement on previous measurements. The $g$-factor measurements are corrected for an ac-magnetic field from trap-drive-induced currents in the electrodes, and data taken over a range of magnetic fields underscores the importance of accounting for this systematic.

physics.atom-ph↗

Suppressing inhomogeneous broadening in a lutetium multi-ion optical clock

We demonstrate precision measurement and control of inhomogeneous broadening in a multi-ion clock consisting of three $^{176}$Lu$^+$ ions. Microwave spectroscopy between hyperfine states in the $^3D_1$ level is used to characterise differential systematic shifts between ions, most notably those associated with the electric quadrupole moment. By appropriate alignment of the magnetic field, we demonstrate suppression of these effects to the $\sim 10^{-17}$ level relative to the $^1S_0\leftrightarrow{}^3D_1$ optical transition frequency. Correlation spectroscopy on the optical transition demonstrates the feasibility of a 10s Ramsey interrogation in the three ion configuration with a corresponding projection noise limited stability of $σ(τ)=8.2\times 10^{-17}/\sqrtτ$

physics.atom-ph↗

Blackbody radiation shift assessment for a lutetium ion clock

We measure the dynamic differential scalar polarizabilities at 10.6 $μ$m for two candidate clock transitions in $^{176}\mathrm{Lu}^+$. The fractional black body radiation (BBR) shifts at 300 K for the $^1S_0 \leftrightarrow {^3D_1}$ and $^1S_0 \leftrightarrow {^3D_2}$ transitions are evaluated to be $-1.36\,(9) \times 10^{-18}$ and $2.70 \,(21) \times10^{-17}$, respectively. The former is the lowest of any established optical atomic clock.

physics.atom-ph↗