SearcharxivSearch

arXiv subjects

Raymond Tomlin

Publications and source records attributed to Raymond Tomlin.

2 recordsLinked to original sources

MHz Gravitational Wave Constraints with Decameter Michelson Interferometers

A new detector, the Fermilab Holometer, consists of separate yet identical 39-meter Michelson interferometers. Strain sensitivity achieved is better than $10^{-21} /{\sqrt{\rm{Hz}}}$ between 1 to 13 MHz from a 130-hr dataset. This measurement exceeds the sensitivity and frequency range made from previous high frequency gravitational wave experiments by many orders of magnitude. Constraints are placed on a stochastic background at 382 Hz resolution. The 3$σ$ upper limit on $Ω_{\rm{GW}}$, the gravitational wave energy density normalized to the closure density, ranges from $5.6 \times 10^{12}$ at 1 MHz to $8.4 \times 10^{15}$ at 13 MHz. Another result from the same dataset is a search for nearby primordial black hole binaries (PBHB). There are no detectable monochromatic PBHBs in the mass range $0.83$ - $3.5 \times 10^{21}$g between the earth and the moon. Projections for a chirp search with the same dataset increases the mass range to $0.59 - 2.5 \times 10^{25}$g and distances out to Jupiter. This result presents a new method for placing limits on a poorly constrained mass range of primordial black holes. Additionally, solar system searches for PBHBs place limits on their contribution to the total dark matter fraction.

astro-ph.IM

First measurements of high frequency cross-spectra from a pair of large Michelson interferometers

Measurements are reported of the cross-correlation of spectra of differential position signals from the Fermilab Holometer, a pair of co-located 39 m long, high power Michelson interferometers with flat, broadband frequency response in the MHz range. The instrument obtains sensitivity to high frequency correlated signals far exceeding any previous measurement in a broad frequency band extending beyond the 3.8 MHz inverse light crossing time of the apparatus. The dominant but uncorrelated shot noise is averaged down over $2\times 10^8$ independent spectral measurements with 381 Hz frequency resolution to obtain $2.1\times 10^{-20} \ \mathrm{m}/\sqrt{\mathrm{Hz}}$ sensitivity to stationary signals. For signal bandwidths $Δf > 11$ kHz, the sensitivity to strain $h$ or shear power spectral density of classical or exotic origin surpasses a milestone $PSD_{δh} < t_p$ where $t_p= 5.39\times 10^{-44}/\mathrm{Hz}$ is the Planck time.

gr-qc