Searcharxiv⌕ Search

arXiv subjects

Raymundo E. Torres-Olguin

Publications and source records attributed to Raymundo E. Torres-Olguin.

2 recordsLinked to original sources

Multivariable Geometric Laplace Transform and Fault Detection in Distributed-Converter Lines

Monitoring a DC line with many distributed power converters is a genuinely spatio-temporal problem: the information about a localized fault travels along the whole conductor and reaches a few measurement points mixed with the dynamics of the line itself. This paper develops a two-dimensional geometric Laplace transform (t,x) -> (s_t,s_x) over a commutative subalgebra of the geometric algebra Cl(4,0), isomorphic to Segre's bicomplex numbers, in which two bivectors B_t and B_x act as independent imaginary units for the temporal and the spatial phase. Because the two phases live in algebraically distinguishable planes, a fault at position x_f leaves a transformed residual that factorizes as F_f(s_t) e^{-s_x x_f}: its temporal nature stays in the first factor and its location can be read as a geometric argument of the second. On this representation we build a transmission-line model of the converter line and its space-time dispersion relation, a distributed control by admittance shaping, including an exact treatment of discrete converter sites (spatial sampling, aliasing, and a per-converter droop realization that is exact on the sub-Nyquist band), and a fault diagnosis chain that detects, localizes and classifies injection-loss, shunt, sensor and local-controller faults, extends to multiple simultaneous faults with automatic order selection, and distinguishes the outage of a plant from a cable defect. As an integral object the transform is known in bicomplex analysis, and with a single independent variable it reduces to the complex Laplace transform; the contribution lies in its geometric embedding and in its operational use for fault diagnosis in distributed-converter networks. All results are reproduced by an accompanying open implementation.

eess.SY↗

Experimental Verification of a Time-Domain Load Identification Method for Single-Phase Circuits

This paper presents experimental validation of a time-domain load parameter determination method for single-phase circuits. The verification is performed in a state-of-the-art smart grid laboratory equipped with power hardware and real-time emulators. The proposed method enables the identification of circuit parameters using only instantaneous voltage and current measurements at the point of common coupling. The experimental setup includes a range of test cases covering linear and non-sinusoidal single-phase conditions. Voltage and current waveforms are acquired, preprocessed, and used to calculate the relevant circuit parameters. The experimental results demonstrate a high degree of accuracy and robustness, with minimal percentage errors across all test cases. The identified parameters show excellent agreement with the theoretical expectations, confirming the validity and applicability of the proposed method to identify the load of single-phase systems. This validation highlights the potential of the method for improved monitoring, control, and protection of smart grids, paving the way for future extensions to three-phase systems and real-time implementations.

eess.SY↗