Scalable Self-Supervised Learning for Multiphase AC-OPF in Distribution Systems with Topology Reconfiguration

The proliferation of distributed energy resources (DERs) in distribution grids enables the active coordination of these assets to reduce costs and enable cleaner operations. Realizing this potential requires solving multiphase AC optimal power flow (AC-OPF) quickly across varying loads, DER availabilities, and topology reconfigurations, at much greater speed and scale than conventional nonlinear solvers. Learning-based surrogates can offer millisecond inference, yet existing methods target largely balanced transmission systems and do not scale to the multiphase, unbalanced, and reconfigurable nature of distribution feeders at utility scale. We present the Penalty + Sequential Linearized Feasibility Seeking (SLFS) algorithm, a self-supervised learning framework for multiphase distribution AC-OPF under switch-induced topology changes. Penalty+SLFS requires no labeled optimal solutions and trains directly from the AC-OPF objective and constraints through a differentiable fixed-point power flow solver, avoiding expensive label generation and admitting robust training procedures. Topology changes are handled efficiently using Sherman-Morrison-Woodbury updates of the admittance-matrix inverse, while an M-step Jacobian approximation accelerates differentiation through the power flow solver. At inference, SLFS repairs any infeasible predictions, providing feasibility guarantees with low computational overhead. On IEEE feeders ranging from 13 to 8,500 nodes, Penalty+SLFS achieves negligible optimality gaps and near-zero constraint violations, delivers up to three orders of magnitude speedups over IPOPT, and remains robust under large distributional shifts, demonstrating a viable path toward real-time, topology-aware AC-OPF for large-scale distribution grids.

eess.SY

Frequency-Aware Sparse Optimization for Diagnosing Grid Instabilities and Collapses

This paper aims to proactively diagnose and manage frequency instability risks from a steady-state perspective, without the need for derivative-dependent transient modeling. Specifically, we jointly address two questions (Q1) Survivability: following a disturbance and the subsequent primary frequency response, can the system settle into a healthy steady state (feasible with an acceptable frequency deviation $Δf$)? (Q2) Dominant Vulnerability: if found unstable, what critical vulnerabilities create instability and/or full collapse? To address these questions, we first augment steady-state power flow states to include frequency-dependent governor relationships (i.e., governor power flow). Afterwards, we propose a frequency-aware sparse optimization that finds the minimal set of bus locations with measurable compensations (corrective actions) to enforce power balance and maintain frequency within predefined/acceptable bounds. We evaluate our method on standard transmission systems to empirically validate its ability to localize dominant sources of vulnerabilities. For a 1354-bus large system, our method detects compensations to only four buses under N-1 generation outage (3424.8 MW) while enforcing a maximum allowable steady-state frequency drop of 0.06 Hz (otherwise, frequency drops by nearly 0.08 Hz). We further validate the scalability of our method, requiring less than four minutes to obtain sparse solutions for the 1354-bus system.

eess.SY

Multi-Period Sparse Optimization for Proactive Grid Blackout Diagnosis

Existing or planned power grids need to evaluate survivability under extreme events, like a number of peak load overloading conditions, which could possibly cause system collapses (i.e. blackouts). For realistic extreme events that are correlated or share similar patterns, it is reasonable to expect that the dominant vulnerability or failure sources behind them share the same locations but with different severity. Early warning diagnosis that proactively identifies the key vulnerabilities responsible for a number of system collapses of interest can significantly enhance resilience. This paper proposes a multi-period sparse optimization method, enabling the discovery of persistent failure sources across a sequence of collapsed systems with increasing system stress, such as rising demand or worsening contingencies. This work defines persistency and efficiently integrates persistency constraints to capture the ``hidden'' evolving vulnerabilities. Circuit-theory based power flow formulations and circuit-inspired optimization heuristics are used to facilitate the scalability of the method. Experiments on benchmark systems show that the method reliably tracks persistent vulnerability locations under increasing load stress, and solves with scalability to large systems (on average taking around 200 s per scenario on 2000+ bus systems).

eess.SY

State and Topology Estimation for Unobservable Distribution Systems using Deep Neural Networks

Time-synchronized state estimation for reconfigurable distribution networks is challenging because of limited real-time observability. This paper addresses this challenge by formulating a deep learning (DL)-based approach for topology identification (TI) and unbalanced three-phase distribution system state estimation (DSSE). Two deep neural networks (DNNs) are trained for time-synchronized DNN-based TI and DSSE, respectively, for systems that are incompletely observed by synchrophasor measurement devices (SMDs) in real-time. A data-driven approach for judicious SMD placement to facilitate reliable TI and DSSE is also provided. Robustness of the proposed methodology is demonstrated by considering non-Gaussian noise in the SMD measurements. A comparison of the DNN-based DSSE with more conventional approaches indicates that the DL-based approach gives better accuracy with smaller number of SMDs.

cs.LG

Mitigation of Saturated Cut-sets During Multiple Outages to Enhance Power System Security

Ensuring reliable operation of large power systems subjected to multiple outages is a challenging task because of the combinatorial nature of the problem. Traditional approaches for security assessment are often limited by their scope and/or speed, resulting in missing of critical contingencies that could lead to cascading failures. This paper proposes a two-component methodology to enhance power system security. The first component combines an efficient algorithm to detect cut-set saturation (called the feasibility test (FT) algorithm) with real-time contingency analysis (RTCA) to create an integrated corrective action (iCA), whose goal is to secure the system against cut-set saturation as well as critical branch overloads. The second component only employs the results of the FT to create a relaxed corrective action (rCA) to secure the system against post-contingency cut-set saturation. The first component is more comprehensive, but the latter is computationally more efficient. The effectiveness of the two components is evaluated based upon the number of cascade triggering contingencies alleviated, and the computation time. The results obtained by analyzing different case-studies on the IEEE 118-bus and 2000-bus synthetic Texas systems indicate that the proposed two-component methodology successfully enhances the scope and speed of power system security assessment during multiple outages.

eess.SY

Time Synchronized State Estimation for Incompletely Observed Distribution Systems Using Deep Learning Considering Realistic Measurement Noise

Time-synchronized state estimation is a challenge for distribution systems because of limited real-time observability. This paper addresses this challenge by formulating a deep learning (DL)-based approach to perform unbalanced three-phase distribution system state estimation (DSSE). Initially, a data-driven approach for judicious measurement selection to facilitate reliable state estimation is provided. Then, a deep neural network (DNN) is trained to perform DSSE for systems that are incompletely observed by synchrophasor measurement devices (SMDs). Robustness of the proposed methodology is demonstrated by considering realistic measurement error models for SMDs. A comparative study of the DNN-based DSSE with classical linear state estimation indicates that the DL-based approach gives better accuracy with a significantly smaller number of SMDs.

cs.LG

Identification of Utility-Scale Renewable Energy Penetration Threshold in a Dynamic Setting

Integration of renewable energy resources with the electric grid is necessary for a sustainable energy future. However, increased penetration of inverter based resources (IBRs) reduce grid inertia, which might then compromise power system reliability. Therefore, power utilities are often interested in identifying the maximum IBR penetration limit for their system. The proposed research presents a methodology to identify the IBR penetration threshold beyond which voltage, frequency, and tie-line limits will be exceeded. The sensitivity of the IBR penetration threshold to momentary cessation due to low voltages, transmission versus distribution connected solar generation, and stalling of induction motors are also analyzed. Dynamic simulation studies conducted on a 24,000-bus model of the Western Interconnection (WI) demonstrate the practicality of the proposed approach.

eess.SY

Fast Identification of Saturated Cut-sets using Graph Search Techniques

When multiple outages occur in rapid succession, it is important to know quickly if the power transfer capability of different interconnections (or cut-sets) of the power network are limited. The algorithm developed in this paper identifies such limited cut-sets very fast, thereby enhancing the real-time situational awareness of power system operators. The significance of the proposed approach is described using the IEEE 39-bus test system, while its computational benefits are demonstrated using relatively large test-cases containing thousands of buses. The results indicate that the proposed network analysis can estimate the impact of an outage on any cut-set of the system and screen out the cut-set that gets saturated by the largest margin, very quickly.

eess.SY

A Micro-PMU Placement Scheme for Distribution Systems Considering Practical Constraints

This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that observing one phase in a distribution circuit does not translate to observing the other phases. Other practical constraints such as presence of distributed loads, unknown regulator/ transformer tap ratios, zero-injection phases (ZIPs), modern smart meters, and multiple switch configurations are also incorporated. The proposed micro-PMU placement problem is solved using integer linear programming (ILP), guaranteeing optimality of results. The uniqueness of the developed algorithm is that it not only minimizes the micro-PMU installations, but also identifies the minimum number of phases that must be monitored by them.

eess.SY

A Graph Theoretic Approach to Power System Vulnerability Identification

During major power system disturbances, when multiple component outages occur in rapid succession, it becomes crucial to quickly identify the transmission interconnections that have limited power transfer capability. Understanding the impact of an outage on these critical interconnections (called saturated cut-sets) is important for enhancing situational awareness and taking correct actions. This paper proposes a new graph theoretic approach for analyzing whether a contingency will create a saturated cut-set in a meshed power network. A novel feature of the proposed algorithm is that it lowers the solution time significantly making the approach viable for real-time operations. It also indicates the minimum amount by which the power transfer through the critical interconnections should be reduced so that post-contingency saturation does not occur. Robustness of the proposed algorithm for enhanced situational awareness is demonstrated using the IEEE-118 bus system as well as a 17,000+ bus model of the Western Interconnection (WI). Comparisons made with different approaches for power system vulnerability assessment prove the utility of the proposed scheme for aiding power system operations during extreme exigencies.

eess.SY

Adaptive LVRT Settings Adjustment for Enhancing Voltage Security of Renewable-Rich Electric Grids

Inverter based renewable generation (RG), especially at the distribution level, is supposed to trip offline during an islanding situation. However, islanding detection is done by comparing the voltage and frequency measurements at the point of common coupling (PCC), with limits defined in the form of ride-through curves. Current practice is to use the same limit throughout the year independent of the operating conditions. This could result in the tripping of RG at times when the system is already weak, thereby posing a threat to voltage security by heavily limiting the load margin (LM). Conversely, heavily relaxing these limits would result in scenarios where the generation does not go offline even during an islanding situation. The proposed methodology focuses on optimizing low-voltage ride-through (LVRT) settings at selective RGs as a preventive control for maintaining a desired steady-state voltage stability margin while not sacrificing dependability during islanding. The proposed process is a multi-stage approach, in which at each stage, a subset of estimated poor-quality solutions is screened out based on various sensitivities. A full continuation power flow (CPFLOW) is only run at the beginning and in the last stage on a handful of remaining candidate solutions, thereby cutting down heavily on the computation time. The effectiveness of the approach is demonstrated on the IEEE 9-bus system.

eess.SY

Critical Clearing Time Sensitivity for Inequality Constrained Systems

With the growth of renewable generation (RG) and the development of associated ride through curves serving as operating limits, during disturbances, on violation of these limits, the power system is at risk of losing large amounts of generation. In order to identify preventive control measures that avoid such scenarios from manifesting, the power system must be modeled as a constrained dynamical system. For such systems, the interplay of feasibility region (man-made limits) and stability region (natural dynamical system response) results in a positively invariant region in state space known as the constrained stability region (CSR). After the occurrence of a disturbance, as it is desirable for the system trajectory to lie within the CSR, critical clearing time (CCT) must be defined with respect to the CSR instead of the stability region as is done traditionally. The sensitivity of CCT to system parameters of constrained systems then becomes beneficial for planning/revising protection settings (which impact feasible region) and/or operation (which impact dynamics). In this paper, we derive the first order CCT sensitivity of generic constrained power systems using the efficient power system trajectory sensitivity computation, pioneered by Hiskens in [1]. The results are illustrated for a single-machine infinite-bus (SMIB) system as well as a multi-machine system in order to gain meaningful insight into the dependence between ability to meet constraints, system stability, and changes occurring in power system parameters, such as, mechanical power input and inertia.

math.DS

A PMU Based Islanding Detection Scheme Immune to Additive Instrumentation Channel Errors

Traditional synchrophasor measurement-based islanding detection techniques have primarily relied on voltage angle measurements and/or their derivatives for successfully detecting islands. However, relatively high instrumentation channel errors associated with phasor measurement unit (PMU) data, can significantly degrade islanding detection accuracies. In this paper, a new islanding detection scheme employing cumulative sum of change in voltage phase angle difference (CUSPAD) is proposed, which is immune to additive instrumentation channel errors in the PMU measurements. The robustness of the proposed islanding detection algorithm is established through application to an 18-bus test system and the IEEE 118-bus system having different wind energy penetration levels. Comparative analysis of the accuracies of the proposed approach (CUSPAD) and the conventional angle difference (AD) approach prove the former's superior performance when additive instrumentation channel errors are present.

eess.SY

Application of Machine Learning for Online Dynamic Security Assessment in Presence of System Variability and Additive Instrumentation Errors

Large-scale blackouts that have occurred in the past few decades have necessitated the need to do extensive research in the field of grid security assessment. With the aid of synchrophasor technology, which uses phasor measurement unit (PMU) data, dynamic security assessment (DSA) can be performed online. However, existing applications of DSA are challenged by variability in system conditions and unaccounted for measurement errors. To overcome these challenges, this research develops a DSA scheme to provide security prediction in real-time for load profiles of different seasons in presence of realistic errors in the PMU measurements. The major contributions of this paper are: (1) develop a DSA scheme based on PMU data, (2) consider seasonal load profiles, (3) account for varying penetrations of renewable generation, and (4) compare the accuracy of different machine learning (ML) algorithms for DSA with and without erroneous measurements. The performance of this approach is tested on the IEEE-118 bus system. Comparative analysis of the accuracies of the ML algorithms under different operating scenarios highlights the importance of considering realistic errors and variability in system conditions while creating a DSA scheme.

eess.SY

Can Predictive Filters Detect Gradually Ramping False Data Injection Attacks Against PMUs?

Intelligently designed false data injection (FDI) attacks have been shown to be able to bypass the $χ^2$-test based bad data detector (BDD), resulting in physical consequences (such as line overloads) in the power system. In this paper, it is shown that if an attack is suddenly injected into the system, a predictive filter with sufficient accuracy is able to detect it. However, an attacker can gradually increase the magnitude of the attack to avoid detection, and still cause damage to the system.