SearcharxivSearch

arXiv subjects

Reiko Orito

Publications and source records attributed to Reiko Orito.

9 recordsLinked to original sources

Calibration and performance of the readout system based on switched capacitor arrays for the Large-Sized Telescope of the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) is the next-generation ground-based very-high-energy gamma-ray observatory. The Large-Sized Telescope (LST) of CTA is designed to detect gamma rays between 20 GeV and a few TeV with a 23-meter diameter mirror. We have developed the focal plane camera of the first LST, which has 1855 photomultiplier tubes (PMTs) and the readout system which samples a PMT waveform at GHz with switched capacitor arrays, Domino Ring Sampler ver4 (DRS4). To measure the precise pulse charge and arrival time of Cherenkov signals, we developed a method to calibrate the output voltage of DRS4 and the sampling time interval, as well as an analysis method to correct the spike noise of DRS4. Since the first LST was inaugurated in 2018, we have performed the commissioning tests and calibrated the camera. We characterised the camera in terms of the charge pedestal under various conditions of the night sky background, the charge resolution of each pixel, the charge uniformity of the whole camera, and the time resolutions with a test pulse and calibration laser.

astro-ph.IM

High purity NaI(Tl) scintillator to search for dark matter

A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powder. The impurity of $^{226}$Ra was reduced less than 100 $μ$Bq/kg in NaI(Tl) crystal. It should be remarked that the impurity of $^{210}$Pb, which is difficult to reduce, is effectively reduced by chemical processing of NaI raw powder down to less than 30 $μ$Bq/kg. The expected sensitivity to cosmic dark matter by using 250 kg of the high purity and large volume NaI(Tl) scintillator (PICO-LON; Pure Inorganic Crystal Observatory for LOw-background Neutr(al)ino) is 7$\times$10$^{-45}$ cm$^{2}$ for 50 GeV$/c^{2}$ WIMPs.

astro-ph.IM

Novel Photo Multiplier Tubes for the Cherenkov Telescope Array Project

Currently the standard light sensors for imaging atmospheric Cherenkov telescopes are the classical photo multiplier tubes that are using bialkali photo cathodes. About eight years ago we initiated an improvement program with the Photo Multiplier Tube (PMT) manufacturers Hamamatsu (Japan), Electron Tubes Enterprises (England) and Photonis (France) for the needs of imaging atmospheric Cherenkov telescopes. As a result, after about 40 years of stagnation of the peak Quantum Efficiency (QE) on the level of 25-27%, new PMTs appeared with a peak QE of 35%. These have got the name super-bialkali. The second significant upgrade has happened very recently, as a result of a dedicated improvement program for the candidate PMT for Cherenkov Telescope Array. The latter is going to be the next generation major instrument in the field of very high energy gamma astrophysics and will consist of over 100 telescopes of three different sizes of 23m, 12m and 4-7m, located both in southern and northern hemispheres. Now PMTs with average peak QE of approximately 40% became available. Also, the photo electron collection efficiency of the previous generation PMTs of 80- 90% has been enhanced towards 95-98% for the new ones. The after-pulsing of novel PMTs has been reduced towards the level of 0.02% for the set threshold of 4 photo electrons. We will report on the PMT development work by the companies Electron Tubes Enterprises and Hamamatsu Photonics K.K. show the achieved results and the current status.

astro-ph.IM

Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon Altitudes with an Electron-tracking Compton Camera

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be ten times better than that of other experiments at around 1 MeV.

astro-ph.IM

Simulation study of electron drift and gas multiplication in Micro Pixel Chamber

The physical processes of charge collection and gas multiplication of a Micro Pixel Chamber (mu-PIC) were studied in detail using a three-dimensional simulation. The collection efficiencies of primary electrons and gas multiplication factors were calculated for several electrode structures. Based on those studies, we analyzed the optimization of the electrode structure of the mu-PIC, in order to obtain a high gas gain of more than 10^4 and a simultaneous suppression of discharges. Consequently, we found that these characteristics strongly depend on the substrate thickness and the anode diameter of the mu-PIC. In addition, a gas gain of 10^5 would be expected for a mu-PIC having a thick substrate of > 150um.

physics.ins-det

MeV Gamma-Ray Imaging Detector with micro-TPC

We propose a new imaging gamma-ray detector in the MeV region. By measuring the directions and energies of not only a scattered gamma ray but also a recoil electron, the direction of an incident gamma ray would be essentially reconstructed event by event. Furthermore, one of two measured (zenith and azimuth) angles of a recoil electron gives us an additional redundancy which enables us to reject the background events by kinematic constraints. In order to measure the track of a recoil electron, the micro Time Projection Chamber($μ$-TPC) has been developed, which can measure the successive positions of the track of charged particles in a few hundred micron meter pitch. The $μ$-TPC consists of the new type of a gas proportional chamber: micro PIxel gas Chamber ($μ$-PIC) which is one of wireless gas chambers and expected to be robust and stable. Using this $μ$-TPC and the Anger camera for the detection of a scattered gamma ray, we have obtained the first gamma-ray image by the full reconstruction of the direction of gamma rays event by event.

astro-ph

Detecting the WIMP-wind via spin-dependent interactions

Revealing the nature of dark matter is one of the most interesting tasks in astrophysics. Measuring the distribution of recoil angles is said to be one of the most reliable methods to detect a positive signature of dark matter. We focused on measurements via spin-dependent interactions, and studied the feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into account the performance of an existing three-dimensional tracking detector. We consequently found that it is highly possible to detect a positive signature of dark matter via spin-dependent interactions.

astro-ph

Performance of a micro-TPC for a time-resolved neutron PSD

We report on the performance of a micro-TPC with a micro pixel chamber($μ$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that the total track length of proton and triton emitted from the $\rm {}^{3}He$(n,p(573 keV))$\rm {}^{3}H(191 keV)$ reaction is about 1.2 cm, and that both particles have large energy losses ($\rm > 200 keV/cm$) in 1 atm Ar+$\rm C_{2}H_{6}(10%)$+${}^{3}$He($< 1%$). These values suit the current performance of the micro-TPC, and we conclude that a time-resolved neutron PSD with spatial resolution of sub-millimeters shall be developed as an application of the micro-TPC.

physics.ins-det

Performance of the TPC with Micro Pixel Chamber Readout: micro-TPC

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($μ$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position sensitive gaseous detector, or the $μ$-PIC, with the detection area of 10$\times$10 cm${}^{2}$ and 65536 anode electrodes of 400 $μ$m pitch. We achieved the gas gain of over 10000 without any other multipliers. With the pipe-line readout system specially developed for the $μ$-PIC, we detected X-rays at the rate as high as 7.7 Mcps. We attached a drift cage with an 8 cm drift length to the $μ$-PIC and developed a micro-TPC. We measured the basic performances of the micro-TPC and took three-dimensional tracks of electrons. We also developed a prototype of the MeV gamma-ray imaging detector which is a hybrid of the micro-TPC and NaI(Tl) scintillators and confirmed its concept by reconstructing the obtained data.

hep-ex