Searcharxiv⌕ Search

arXiv subjects

Reina H. Maruyama

Publications and source records attributed to Reina H. Maruyama.

12 recordsLinked to original sources

Design of ALPHA Phase I: A Plasma Haloscope for 10--20 GHz Post-Inflation Axions

The axion is a well-motivated hypothetical particle capable of resolving both the strong CP problem and the dark matter mystery, with recent post-inflationary cosmological simulations favoring masses above 40 μeV. Plasma haloscopes serve as a promising experimental approach to reach theoretically preferred sensitivities in this mass range. ALPHA, hosted at Yale Wright Laboratory, is an international collaboration developing plasma haloscopes to search for QCD dark matter axions. In this letter we present the detailed design and sensitivity projection for the first phase of the ALPHA experiment, which will search the mass range from 10 GHz to 20 GHz (~40 μeV to 80 μeV). This search will make use of wire-array plasma resonators to decouple the physical size from the resonant frequency, a limitation typically faced by traditional microwave cavities, allowing broadband sensitivity approaching KSVZ coupling strengths.

hep-ex↗

Development and Initial Performance of an Upgraded NaI(Tl) Crystal Encapsulation for COSINE-100U

The COSINE-100 experiment was designed to test the DAMA/LIBRA annual-modulation claim using low-background NaI(Tl) detectors. For the COSINE-100U upgrade, we developed a new crystal-encapsulation system to increase light-collection efficiency while preserving long-term detector stability, thereby improving sensitivity to low-mass dark matter. The upgraded design eliminates the quartz optical windows used in COSINE-100 and directly couples the photomultiplier tubes (PMTs) to the crystal end faces through 2-mm-thick silicone optical pads, thereby reducing the number of optical interfaces. For the larger crystals, the crystal edges were beveled to guide scintillation light more efficiently onto 3-inch high-quantum-efficiency PMTs. The performance study uses 2462~h (102.6~days) of room-temperature COSINE-100U data and, for direct background comparisons, reference COSINE-100 data acquired near the end of operation. 698~h (29.1~days) of COSINE-100 data acquired near the end of operation in March 2023. All eight crystals showed higher light yields than in COSINE-100, with values ranging from 15.8 to 27.7~p.e./keV; six crystals exceeded 20~p.e./keV. The measured bulk-$α$ rates were lower than the COSINE-100 values and consistent with the expected time evolution of internal $^{210}$Pb, while the 1--2-MeV surface-$α$ rates were substantially reduced. The upgrade also restored two crystals that had previously been excluded from the COSINE-100 physics analysis because of poor optical performance. Independent validation tests demonstrated that the encapsulation remains mechanically robust and optically stable during long-term immersion in liquid scintillator at low temperature. This paper presents the encapsulation design, the room-temperature detector performance, and the reduction in surface-related backgrounds achieved at the Yemilab facility.

physics.ins-det↗

Dark Matter Searches with Sodium Iodide Detectors

The search for the identity of dark matter remains one of the most intriguing challenges in physics today, driving innovative advances in experiment and theory. Thallium-doped sodium iodide (NaI) detectors have played a pivotal role in this context. This review outlines the scientific landscape surrounding NaI detectors, emphasizing their role in the broader context of dark matter research. We begin with a brief description of characteristics that make these detectors well-suited for dark matter detection. We then provide a historical overview and explore the results from the DAMA/NaI and DAMA/LIBRA experiments, which have reported annual modulation signals consistent with dark matter interactions--a signal that to date no other experiment has replicated. We discuss recent results from NaI-based experiments launched, in part, to resolve this tantalizing anomaly. We conclude with a summary of the status and prospects for current and future NaI-based dark matter searches.

hep-ex↗

Performance of a SiPM-based, plastic scintillator muon veto prototype for CUPID

CUPID will be a next-generation experiment searching for neutrinoless double beta decay in the inverted mass ordering regime. The reduction of backgrounds in the region of interest is critical to the performance of the experiment. Despite its underground location, muon-induced events will be a non-negligible source of background for CUPID, and their mitigation will be critical in reaching CUPID's target sensitivity. This mitigation will be achieved with a muon veto system, which must fit within the physical constraints of the existing infrastructure while maximizing geometrical coverage. We present the design, construction, and characterization of prototypes for a modular system of plastic scintillator panels with embedded plastic wavelength-shifting fibers connected to silicon photomultipliers for the CUPID muon veto. The 100$\, \times \,$50$\, \times \, $2.5\,cm$^3$ panel prototype presented here exhibited a light yield of ($55.9 \,\pm \,1.5$)\,p.e./MeV with a position reconstruction resolution of 25$\,\times \,$25\,cm$^2$. This design also achieves a muon detection efficiency of $(98\,\pm \,1)\%$. We compare the light yield, uniformity, and position reconstruction potential of different prototype designs.

physics.ins-det↗

Rydberg-atom-based single-photon detection for haloscope axion searches

We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 $μ$eV and 200 $μ$eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements up to a factor of $10^4$ over traditional linear amplifier readout, and is compatible with many different haloscope cavities. We identify multiple haloscope designs that could use our Rydberg-atom-based single-photon detector to search for QCD axions with masses above 40 $μ$eV (10 GHz), currently a minimally explored parameter space.

hep-ex↗

Quantum Sensors for High Energy Physics

Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Standard Model itself including the Strong CP problem in QCD. Resulting experimental needs typically involve the measurement of very low energy impulses or low power periodic signals that are normally buried under large backgrounds. This report documents the findings of the 2023 Quantum Sensors for High Energy Physics workshop which identified enabling quantum information science technologies that could be utilized in future particle physics experiments, targeting high energy physics science goals.

hep-ex↗

An improved synthetic signal injection routine for the Haloscope At Yale Sensitive To Axion Cold dark matter (HAYSTAC)

Microwave cavity haloscopes are among the most sensitive direct detection experiments searching for dark matter axions via their coupling to photons. When the power of the expected microwave signal due to axion-photon conversion is on the order of $10^{-24}$~W, having the ability to validate the detector response and analysis procedure by injecting realistic synthetic axion signals becomes helpful. Here we present a method based on frequency hopping spread spectrum for synthesizing axion signals in a microwave cavity haloscope experiment. It allows us to generate a narrow and asymmetric shape in frequency space that mimics an axion's spectral distribution, which is derived from a Maxwell-Boltzmann distribution. In addition, we show that the synthetic axion's power can be calibrated with reference to the system noise. Compared to the synthetic axion injection in HAYSTAC phase I, we demonstrated synthetic signal injection with a more realistic lineshape and calibrated power.

physics.ins-det↗

On the use of dielectric elements in axion searches with microwave resonant cavities

This study explores the primary effects of dielectric materials in a resonant cavity-based search for axion dark matter. While dielectrics prove beneficial in numerous cases, their incorporation may lead to less-than-optimal performance, especially for the lowest TM mode. Additionally, the stronger confinement of the electric field inside the dielectrics can exacerbate mode mixings, in particular for higher-order modes. Case studies have been carried out using a combination of analytical solutions and numerical simulations. The findings indicate dielectric cavities employing the $\text{TM}_{010}$ mode experience a significant reduction in sensitivity when compared to a similar search conducted in a cavity at equivalent frequency using no dielectrics.

physics.ins-det↗

Report of the Instrumentation Frontier Working Group for Snowmass 2021

Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.

hep-ex↗

EIT spectroscopy of high-lying Rydberg states in $^{39}K$

We present a study of the Rydberg spectrum in $^{39}K$ for $nS$ and $nD_{3/2}$ series connected to $5^2P_{1/2}$ using two-photon spectroscopy based on EIT in a heated vapor cell. We observed some 80 transitions from $5P_{1/2}$ to Rydberg states with principal quantum numbers $n\sim50-90$, and determined their transition frequencies and state energies with sub-GHz precision. Our spectroscopy results lay the groundwork for using Rydberg atoms as sensitive microwave photon detectors in searches for dark matter axions in the $\sim40-200$ $μ$eV mass range, which is a prime range for future axion searches suggested by theory studies.

physics.atom-ph↗

Searching for Dark Photons with Existing Haloscope Data

The dark (or hidden) photon is a massive U(1) gauge boson theorized as a dark force mediator and as a dark matter candidate. Dark photons can be detected with axion cavity haloscopes by probing for a power excess caused by the dark photon's kinetic mixing with Standard Model photons. Haloscope axion exclusion limits may therefore be converted into competitive dark photon parameter limits via the calculation of a corresponding dark photon to photon coupling factor. This calculation allows for an improvement in sensitivity of around four orders of magnitude relative to other dark photon exclusions and may be attained using existing data. We present how one converts haloscope axion search limits and a summary of relevant experimental parameters from published searches. In addition, we have included the code that can be used to generate our dark photon exclusion limits for the cases described in this paper. Finally, we present limits on the kinetic mixing coefficient between dark photons and the Standard Model photons based on existing haloscope axion searches.

hep-ph↗

An experiment to search for dark matter interactions using sodium iodide detectors

Observations of galaxies and primordial radiation suggest that the Universe is made mostly of non-luminous dark matter. Several types of new fundamental particles have been proposed as candidates for dark matter such as weakly interacting massive particles (WIMPs) but no definitive signal has been seen despite concerted efforts by many collaborations. One exception is the much-debated claim by the DAMA collaboration of a statistically significant annual modulation in the event rate of their experiment with a period and phase consistent with that expected from WIMP dark matter. Several groups have been working to develop experiments with the aim of reproducing DAMA's results using the same target medium. Here we report results from the initial operation of the COSINE-100 experiment. COSINE-100 uses sodium iodide as the target medium-the same medium as DAMA-and is designed to carry out a model-independent test of DAMA's claim. Initial data based on the first 59.5 days indicate that there is no excess of events over the expected background, confirming that DAMA's annual modulation signal is in severe tension with results from other experiments under the assumption of dark matter having spin independent interactions and the Standard Halo Model. COSINE-100 is now taking data to study the presence of dark matter-induced annual modulation in the event rate of the sodium iodide detectors.

astro-ph.IM↗