Searcharxiv⌕ Search

arXiv subjects

Renxian Yuan

Publications and source records attributed to Renxian Yuan.

8 recordsLinked to original sources

Robust Betatron-Tune Measurement from Schottky Spectra: Complementary Classical and Deep-Learning Paradigms

Schottky spectra provide key beam diagnostics, with betatron sidebands encoding the fractional tune. Reliable tune measurement is particularly important for third-order resonance slow extraction in compact medical proton synchrotrons, where low signal-to-noise ratios and limited frequency resolution can compromise conventional peak-detection and curve-fitting methods. This work develops two complementary tune estimators with a shared spectral front-end but different temporal representations. The classical estimator coherently pools motion-compensated spectra, detects the sideband using a multi-width matched-filter bank, and performs sub-bin estimation through local argmax and an adaptive MAD-gated centroid. The deep-learning estimator converts each spectrum into a tune-likelihood map using a convolutional neural network with FFT-based global convolutions, then propagates the posterior with a discrete two-dimensional (q,v) Bayesian tracker under a Gaussian motion model while also reporting posterior uncertainty. On a synthetic dynamic-tune benchmark, the deep-learning estimator outperforms published baselines across the operating range, while the classical estimator exceeds the latency-compensated baseline and requires neither training data nor GPU acceleration. On near-stationary SAPT beam data, both methods operate end-to-end, with the deep-learning model requiring no retraining. Median per-frame latency remains below 1 ms on commodity hardware, supporting real-time-capable tune measurement in compact medical synchrotrons.

physics.acc-ph↗

Real-Time-Capable Betatron Tune Measurement from Schottky Spectra Using Deep Learning and Uncertainty-Aware Kalman Filtering

Betatron tune measurement is essential for beam control in compact proton-therapy synchrotrons, yet conventional peak-detection techniques are not robust under the low signal-to-noise ratio (SNR) conditions typical of these machines. This work presents a lightweight convolutional neural network that performs real-time tune extraction from Schottky spectra with sub-millisecond inference latency and calibrated uncertainty estimates. The model uses attention-based pooling for reliable peak localization and a dual-branch architecture that jointly predicts the tune and its associated uncertainty. Trained with a Laplace negative log-likelihood loss, it produces uncertainty estimates whose magnitude tracks the instantaneous prediction error, which enables uncertainty-aware Kalman filtering for temporal smoothing. Experiments on a large synthetic dataset spanning SNR levels from 0 to $-20$\,dB demonstrate substantial performance gains over traditional peak-detection baselines, while the Kalman filter further suppresses transient outliers in time-series operation. Preliminary validation on operational beam data confirms stable tune tracking without retraining. With only about $2.0\times 10^{4}$ trainable parameters and real-time inference on commodity GPU hardware, the proposed diagnostic offers a practical solution for rapid and accurate betatron tune monitoring in compact medical synchrotrons and similar accelerators.

physics.acc-ph↗

High-Accuracy Schottky Diagnostics for Low-SNR Betatron Tune Measurement in Ramping Synchrotrons

This study introduces a novel real-time betatron tune measurement algorithm, utilizing Schottky signals and an FPGA-based backend architecture, specifically designed for rapidly ramping synchrotrons, with particular application to the Shanghai Advanced Proton Therapy (SAPT) facility. The developed algorithm demonstrates improved measurement accuracy under challenging operational conditions, especially in scenarios with limited sampling time and signal-to-noise ratios (SNR) as low as \(-20\) dB. By applying Short-Time Fourier Transform (STFT) analysis, the algorithm effectively accommodates the rapid increase in revolution frequency from 4 MHz to 7.5 MHz over 0.35 seconds, along with tune shifts. A macro-particle simulation methodology is employed to generate Schottky signals, which are then combined with real noise collected from an analog-to-digital converter (ADC) to simulate practical conditions. The proposed betatron tune measurement algorithm integrates advanced spectral processing techniques and an enhanced peak detection algorithm specifically tailored for low SNR conditions. Experimental validation confirms the superior performance of the proposed algorithm over conventional approaches in terms of measurement accuracy, stability, and system robustness, while meeting the stringent operational requirements of proton therapy applications. This innovative approach effectively addresses critical limitations associated with Schottky diagnostics for betatron tune measurement in rapidly ramping synchrotrons operating under low SNR conditions, laying a robust foundation and providing a viable solution for advanced applications in proton therapy and related accelerator physics fields.

physics.acc-ph↗

Beam Test Results of High Q CBPM prototype for SXFEL

Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics has developed a high Q cavity beam position monitor (CBPM) that the resonant frequency is 4.7 GHz and relevant BPM electronics include dedicated RF front-end and home-made digital BPM (DBPM) also has been done. The cavity design, cold test, system architecture and the beam test with three adjacent pickups has been performed in Shanghai Deep ultraviolet free electron laser(SDUV-FEL) facility are included. The beam experiment results show that the physical design of our CBPM is consistent with the expectations basically and the beam position resolution can fulfill the resolution requirements for the SXFEL project if we optimize the beam conditions.

physics.acc-ph↗

Experimental Study using Touschek Lifetime as Machine Status Flag in SSRF

The stabilities of the beam and machine have almost the highest priority in a modern light source. Although a lot of machine parameters could be used to represent the beam quality, there lacks a single one that could indicate the global information for the machine operators and accelerator physicists, recently. A new parameter has been studied for the last few years as a beam quality flag in Shanghai Synchrotron Radiation Facility (SSRF). Calculations, simulations and detailed analysis of the real-time data from the storage ring had been made and interesting results had confirmed its feasibility.

physics.acc-ph↗

Performance Evaluation of BPM System in SSRF Using PCA Method

The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related informations were extracted before the evaluation of the BPM performance. A series of studies had been made in Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved as an effective and robust method in the performance evaluations of our BPM system.

physics.acc-ph↗

Design and test of SX-FEL cavity BPM

This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1μm, even 0.1μm. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. The isolation of TM010 mode is about 117dB, and the shunt impedance is about 200Ω@4.65GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90mV/mm when the source was 6dBm, and the accomplishable minimum voltage was about 200μV. The resolution of the CBPM was about 0.1μm from the linear fitting result based on the cold test.

physics.acc-ph↗