SearcharxivSearch

arXiv subjects

Reynold J. Cooper

Publications and source records attributed to Reynold J. Cooper.

4 recordsLinked to original sources

Automatic calibration of gamma-ray detectors deployed in uncontrolled environments

Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation. Traditional calibration methods often rely on power-intensive temperature stabilization or peak-locking algorithms that are susceptible to environmental changes. This publication presents a novel software-based calibration method that eliminates the need for active temperature control by utilizing full-spectrum analysis. The method continuously updates the calibration parameters by fitting the spectral data with a series of background radiation contributions (K, U, Th series, radon progeny and cosmics) combined with a Monte-Carlo-based physical detector model that incorporates light yield non-proportionality and photomultiplier tube saturation. Performance was validated using simulated data, measurements in an environmental chamber across a wide temperature range (-25C to +50C), and data from a multi-day outdoor field deployment. Results demonstrate that the method successfully maintains stable energy calibration despite significant ambient temperature variations and precipitation events. The technique effectively decouples instrumental drift from spectral changes caused by environmental background fluctuations. This approach provides a robust, automated, and low-power alternative to conventional calibration techniques, enabling the practical deployment of large-scale, unattended networked detector systems.

physics.ins-det

Curation and Dissemination of Complex Multi-modal Data Sets for Radiation Detection, Localization, and Tracking

The PANDAWN sensor network in Chicago, IL, is a state-of-the-art test-bed for networked, multi-modal sensing. It integrates AI/data science methods into its operation, from data acquisition to automated data labeling and curation workflows. The curation and dissemination of diverse multi-modal data sets will enable the development of new radiological/nuclear (R/N) detection, localization, and tracking algorithms, and methods relevant across the nonproliferation mission space. This paper first introduces the PANDAWN sensor network and the features that make it stand out from previous multi-modal data acquisition efforts. We then review the various data streams acquired on the PANDAWN nodes, and present the implementation of an automated data curation pipeline that includes the labeling of radiation and contextual data streams. We finally provide a short overview of different studies that leveraged the curated data sets.

physics.app-ph

Free-moving Quantitative Gamma-ray Imaging

The ability to map and estimate the activity of radiological source distributions in unknown three-dimensional environments has applications in the prevention and response to radiological accidents or threats as well as the enforcement and verification of international nuclear non-proliferation agreements. Such a capability requires well-characterized detector response functions, accurate time-dependent detector position and orientation data, a digitized representation of the surrounding 3D environment, and appropriate image reconstruction and uncertainty quantification methods. We have previously demonstrated 3D mapping of gamma-ray emitters with free-moving detector systems on a relative intensity scale using a technique called Scene Data Fusion (SDF). Here we characterize the detector response of a multi-element gamma-ray imaging system using experimentally benchmarked Monte Carlo simulations and perform 3D mapping on an absolute intensity scale. We present experimental reconstruction results from hand-carried and airborne measurements with point-like and distributed sources in known configurations, demonstrating quantitative SDF in complex 3D environments.

physics.ins-det

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four $8$ $μ$Ci $^{137}$Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ${\sim}20$ cm and activity accuracies (unsigned) of ${\sim}20\%$, given measurement times of two to three minutes and distances of closest approach (to any source) of ${\sim}20$ cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by $75$ cm or more given only ${\sim}60$ s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ${\sim}40\%$, but obtained source separation distances accurate to within $15$ cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

physics.ins-det