Searcharxiv⌕ Search

arXiv subjects

Rianne A. Weber

Publications and source records attributed to Rianne A. Weber.

2 recordsLinked to original sources

Designing UNICORN: a Unified Benchmark for Imaging in Computational Pathology, Radiology, and Natural Language

Foundation models are changing the way we develop medical artificial intelligence. By learning broadly generalizable features across diverse data modalities, a single model can be rapidly adapted to address multiple modalities and tasks with minimal supervision. This potential comes with the urgent need to reliably benchmark, understand and compare the performance and clinical impact of foundation models across data modalities and clinical tasks. We introduce UNICORN, a fundamentally new benchmarking concept for medical foundation models. UNICORN brings four main contributions to medical artificial intelligence. First, a framework that enables a one-to-many benchmarking approach, where a single foundation model is tested across multiple tasks and data modalities. Here, we populate it with 20 tasks across radiology, pathology, and clinical text, covering classification, detection, segmentation, regression, and vision-language generation. Second, a publicly available evaluation platform that implements, for the first time, a two-step approach to run foundation models for data encoding followed by custom task-specific adaptation via few-shot learning and linear probing mechanisms. Third, we create a meta-model that combines state-of-the-art foundation models in pathology, radiology and language with novel task-specific adapters that address all UNICORN tasks, which we refer to as Unicorn Model-0 (UM-0). Finally, we design a novel UNICORN score to benchmark and compare model performance across all tasks. We present the results of UM-0 using sequestered test data from over 2,400 patients, 3,700 vision cases, and 2,400 clinical reports from 17 institutions across eight countries, spanning eight anatomical regions and four imaging modalities. Data, baselines, and evaluation platform are publicly accessible at unicorn.grand-challenge.org.

cs.CV↗

A deep learning model to reduce agent dose for contrast-enhanced MRI of the cerebellopontine angle cistern

Objectives: To evaluate a deep learning (DL) model for reducing the agent dose of contrast-enhanced T1-weighted MRI (T1ce) of the cerebellopontine angle (CPA) cistern. Materials and methods: In this multi-center retrospective study, T1 and T1ce of vestibular schwannoma (VS) patients were used to simulate low-dose T1ce with varying reductions of contrast agent dose. DL models were trained to restore standard-dose T1ce from the low-dose simulation. The image quality and segmentation performance of the DL-restored T1ce were evaluated. A head and neck radiologist was asked to rate DL-restored images in multiple aspects, including image quality and diagnostic characterization. Results: 203 MRI studies from 72 VS patients (mean age, 58.51 \pm 14.73, 39 men) were evaluated. As the input dose increased, the structural similarity index measure of the restored T1ce increased from 0.639 \pm 0.113 to 0.993 \pm 0.009, and the peak signal-to-noise ratio increased from 21.6 \pm 3.73 dB to 41.4 \pm 4.84 dB. At 10% input dose, using DL-restored T1ce for segmentation improved the Dice from 0.673 to 0.734, the 95% Hausdorff distance from 2.38 mm to 2.07 mm, and the average surface distance from 1.00 mm to 0.59 mm. Both DL-restored T1ce from 10% and 30% input doses showed excellent images, with the latter being considered more informative. Conclusion: The DL model improved the image quality of low-dose MRI of the CPA cistern, which makes lesion detection and diagnostic characterization possible with 10% - 30% of the standard dose.

cs.CV↗