SearcharxivSearch

arXiv subjects

Richard Plackett

Publications and source records attributed to Richard Plackett.

10 recordsLinked to original sources

Reconstruction Bias in Timepix4 Subpixel Centroiding for Electron Imaging

Subpixel centroiding is widely used to improve the spatial resolution of hybrid pixel detectors for electron imaging by estimating the true interaction position within an entry pixel. Existing centroiding strategies are typically optimised using localisation accuracy. However, observations show that improved localisation does not necessarily translate into improved modulation transfer function (MTF) or reliable virtual-pixel rebinning. This work proposes a unified interpretation of these observations based on the ambiguity of the centroid reconstruction problem. We show that observable-based centroid estimators solve an intrinsically non-unique inverse problem using deterministic reconstruction rules, which can introduce entry-phase-dependent reconstruction bias that governs the spatial distribution of reconstructed subpixel coordinates. This framework explains why localisation accuracy alone is insufficient to predict imaging performance and identifies approximate intra-pixel translational symmetry as a prerequisite for faithful virtual-pixel imaging. The proposed interpretation is evaluated using simulated 200 keV and 300 keV electron data together with measured 200 keV data acquired with a Timepix4 detector. Comparisons of charge-weighted, timing-based, and morphology-dependent centroiding strategies demonstrate that estimators with similar localisation performance can exhibit markedly different MTFs and rebinned flat-field behaviour. The results suggest that future centroid optimisation should consider subpixel phase bias and rebinnability alongside localisation accuracy.

physics.ins-det

Detective Quantum Efficiency of the Timepix4 Hybrid Pixel Detector and its Application to Parallel-Beam Diffraction

The detective quantum efficiency (DQE) and normalised noise power spectrum (NNPS) of the Timepix4 hybrid pixel detector in event-driven mode in TEM have been measured at 100 kV and 200 kV. In a raw data readout mode, the zero-frequency DQE exceeds 0.9 at both 100 kV and 200 kV. At the Nyquist frequency, the DQE remains above 0.2 at 100 kV but drops close to zero at 200 kV. Initial parallel-beam diffraction data from a polycrystalline gold nanoparticle sample is reported which shows that at 200 kV Timepix4 can detect weak diffracted information beyond a 75 mrad half-angle.

physics.ins-det

Letter Of Intent for a future $\mu^+ \to \mathrm{e}^+ \gamma$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $\mu^+ \to \mathrm{e}^+ \gamma$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $\mu^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $\mu \to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $\mu^+ \to \mathrm{e}^+ \gamma$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $\mu^+ \to \mathrm{e}^+ \gamma$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $\mu^+ \to \mathrm{e}^+ \gamma$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex

Bounds on heavy axions with an X-ray free electron laser

We present new exclusion bounds obtained at the European X-ray Free Electron Laser facility (EuXFEL) on axion-like particles (ALPs) in the mass range 10^{-3} eV < m_a < 10^4 eV. Our experiment exploits the Primakoff effect via which photons can, in the presence of a strong external electric field, decay into axions, which then convert back into photons after passing through an opaque wall. While similar searches have been performed previously at a 3^rd generation synchrotron, our work demonstrates improved sensitivity, exploiting the higher brightness of X-rays at EuXFEL.

hep-ph

Dose rate dependence of TID damage to 65 nm CMOS transistors in X-ray irradiations of the ATLAS ITk Pixel ASIC (ITkPix)

The ATLAS Inner Tracker (ITk) upgrade for the High-Luminosity LHC (HL-LHC) requires a radiation-tolerant pixel readout chip, which must withstand a total ionising dose (TID) of up to 1 Grad. The readout ASIC for the ITk upgrade has been designed by the RD53 collaboration using 65 nm CMOS technology. In order to characterise the radiation tolerance of the chip digital logic, the RD53 ASICs include ring oscillators, which can be used to measure gate delay degradation. Extensive X-ray irradiation studies of the ring oscillators have been performed on the ITk Pixel pre-production readout ASIC, ITkPixV1. A dependence of radiation damage on dose rate has been observed in 65 nm CMOS technology. This paper aims to quantify the dose rate dependence of TID damage to the ITkPix ring oscillators and, therefore, the ITkPix ASIC digital logic. X-ray irradiations at different dose rates between 20 krad/h and 30 Mrad/h are compared. A dose rate dependence is observed, with 2-3 times more damage at the lowest dose rate of 20 krad/h, compared to 4 Mrad/h. The dose rate dependence was also observed to be dependent on transistor size and type.

physics.ins-det

Measurement of the relative response of TowerJazz Mini-MALTA CMOS prototypes at Diamond Light Source

This paper outlines the results of investigations into the effects of radiation damage in the mini-MALTA prototype. Measurements were carried out at Diamond Light Source using a micro-focus X-ray beam, which scanned across the surface of the device in 2 $\mathrm{μm}$ steps. This allowed the in-pixel photon response to be measured directly with high statistics. Three pixel design variations were considered: one with the standard continuous $\mathrm{n^-}$ layer layout and front-end, and extra deep p-well and $\mathrm{n^-}$ gap designs with a modified front-end. Five chips were measured: one unirradiated, one neutron irradiated, and three proton irradiated.

physics.ins-det

Automatic Selection of CDS Timing Parameters

CDS is a process used in many CCD readout systems to cancel the reset noise component that would otherwise dominate. CDS processing typically consists of subtracting the integrated video signal during a "signal" period from that during a "reset" period. The response of this processing depends therefore on the shape of the video signal with respect to the integration bounds. In particular, the amount of noise appearing in the final image and the linearity of the pixel value with signal charge are affected by the choice of the CDS timing intervals. In this paper, we use a digital CDS readout system which highly oversamples the video signal (as compared with the pixel rate) to reconstruct pixel values for different CDS timings using identical raw video signal data. We use this technique to develop insights into optimal strategy for selecting CDS timings both in the digital case (where the raw video signal may be available), and in the general case where it is not. In particular, we show that the linearity of the CDS operation allows subtraction of the raw video signals of pixels in bias images from those in illuminated images to directly show the effects of CDS processing on the final (subtracted) pixel values.

astro-ph.IM

An Electro - Optical Test System for Optimising Operating Conditions of CCD sensors for LSST

We describe the commissioning of a system which has been built to investigate optimal operation of CCDs for the LSST telescope. The test system is designed for low vibration, high stability operation and is capable of illuminating a detector in flat-field, projected spot, projected pattern and Fe-55 configurations. We compare and describe some considerations when choosing a gain calibration method for CCDs which exhibit the brighter-fatter effect. An optimisation study on a prototype device of gain and full well with varying back substrate bias and gate clock levels is presented.

astro-ph.IM

The Timepix Telescope for High Performance Particle Tracking

The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed around the dual capability of the Timepix ASICs to provide information about either the deposited charge or the timing information from tracks traversing the 14 x 14mm matrix of 55 x 55 um pixels. The rate of reconstructed tracks available is optimised by taking advantage of the shutter driven readout architecture of the Timepix chip, operated with existing readout systems. Results of tests conducted in the SPS North Area beam facility at CERN show that the telescope typically provides reconstructed track rates during the beam spills of between 3.5 and 7.5 kHz, depending on beam conditions. The tracks are time stamped with 1 ns resolution with an efficiency of above 98% and provide a pointing resolution at the centre of the telescope of 1.6 um . By dropping the time stamping requirement the rate can be increased to 15 kHz, at the expense of a small increase in background. The telescope infrastructure provides CO2 cooling and a flexible mechanical interface to the device under test, and has been used for a wide range of measurements during the 2011-2012 data taking campaigns.

physics.ins-det

Charged Particle Tracking with the Timepix ASIC

A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.

physics.ins-det