SearcharxivSearch

arXiv subjects

Richard Tyson

Publications and source records attributed to Richard Tyson.

4 recordsLinked to original sources

Validating a BDT-based Electron-Positron Identification Algorithm at CLAS12 with Experimental Data

This article presents a machine-learning, particle-identification algorithm for electrons and positrons in the CLAS12 experiment. The main objective was to minimize charged-pion contamination for both experimental and simulated data. We developed, evaluated and validated two BDT models with different input features, both trained on simulated samples, and conducted rigorous validation using both simulated and experimental data to ensure reliability. Our results show the effectiveness of the applied models in mitigating background contamination. By retaining more than 90\% of leptons in the simulated samples, the charged-pion background is largely reduced. Performance was evaluated on experimental data, providing a framework to validate such approaches at CLAS12 and future electron-beam facilities.

hep-ex

GPT-Based Fast Simulation of CLAS12 Detector Hits via Conditional Autoregressive Generation

Modern particles physics experiments have demonstrated an increasing need for fast, high-fidelity detector simulation as detector components have improved and subsequent computational requirements approach the limits of available resources. Recently, deep generative models have emerged as a promising alternative to traditional Monte-Carlo methods, with recent works drawing inspiration from large language models (LLMs) and self-supervised next-token prediction methods. In this work, we present an application of a GPT-style autoregressive transformer as a fast surrogate model for the calorimeter inside the CLAS12 experiment at the Thomas Jefferson National Accelerator Facility. The model is conditioned on incident momentum and generates realistic detector hits autoregressively across all nine calorimeter layers as sequences of strip, ADC, and TDC tokens. We demonstrate that the model faithfully reproduces hit multiplicity, spatial distributions, energy deposits, and the energy-momentum response of the electromagnetic calorimeter. The generator achieves inference rates exceeding 700 events per second on a single GPU, providing a substantial speedup over traditional Geant4-based simulations while maintaining physics fidelity essential for high-luminosity experimental programs.

physics.ins-det

Online Electron Reconstruction at CLAS12

Online reconstruction is key for monitoring purposes and real time analysis in High Energy and Nuclear Physics experiments. A necessary component of reconstruction algorithms is particle identification that combines information left by a particle passing through several detector components to identify the particle's type. Of particular interest to electroproduction Nuclear Physics experiments such as CLAS12 is electron identification which is used to trigger data recording. A machine learning approach was developed for CLAS12 to reconstruct and identify electrons by combining raw signals at the data acquisition level from several detector components. This approach achieves an electron identification purity above 75% whilst retaining an efficiency close to 100%. The machine learning tools are capable of running at high rates exceeding the data acquisition rates and will allow electron reconstruction in real time. This work enhances online analyses and monitoring and can contribute to improved triggering at CLAS12. This machine learning driven approach will also be crucial for experiments aiming to transition to streaming readout operations where online reconstruction will be a key component of the data taking paradigm.

physics.ins-det

Deep Learning Level-3 Electron Trigger for CLAS12

Fast, efficient and accurate triggers are a critical requirement for modern high-energy physics experiments given the increasingly large quantities of data that they produce. The CEBAF Large Acceptance Spectrometer (CLAS12) employs a highly efficient electron trigger to filter the amount of recorded data by requiring at least one electron in each event, at the cost of a low purity in electron identification. Machine learning algorithms are increasingly employed for classification tasks such as particle identification due to their high accuracy and fast processing times. In this article, we show how a convolutional neural network could be deployed as a Level 3 electron trigger at CLAS12. We demonstrate that the AI trigger would achieve a significant data reduction compared to the traditional trigger, whilst preserving a 99.5\% electron identification efficiency. The AI trigger purity as a function of increased luminosity is improved relative to the traditional trigger. As a consequence, this AI trigger can achieve a data recording reduction improvement of 0.33\% per nA when compared to the traditional trigger whilst maintaining an efficiency above 99.5\%. A reduction in data output also reduces storage costs and post-processing times, which in turn reduces the time to the publication of new physics measurements.

physics.ins-det