SearcharxivSearch

arXiv subjects

Rishabh Bajpai

Publications and source records attributed to Rishabh Bajpai.

7 recordsLinked to original sources

Direct stroke measurement of Piezos for cavity frequency tuner of the ILC prototype cryomodule using a Laser Displacement Sensor

Piezoelectric actuators are critical for achieving high accelerating gradients and preventing RF trips in narrow-bandwidth superconducting radio-frequency (SRF) cavities by compensating for detuning caused by Lorentz force detuning. Depending on the maximum acceleration gradient an appropriate piezo stroke requirement has to be fulfilled. Since the stroke of piezo actuators decreases at cryogenic temperatures, evaluating their performance under such conditions is essential. Common characterization methods either use the SRF cavity itself as a sensor or rely on capacitance measurements during cool-down. Both these approaches do not measure the stroke directly and involve a trade-off between measurement precision and experimental simplicity, as well as cost and time. We developed a new method for the direct and precise measurement of piezo stroke at cryogenic temperature inside a cryocooler-cooled cryostat using a laser displacement sensor. The setup was used to characterize and evaluate two piezo actuators for cavity frequency tuners of the ILC prototype cryomodule, which is currently being built at KEK. In this article we are reporting on the development, setup, test, and application of this novel method, allowing the direct stroke measurement of piezos in vacuum and at cryogenic temperatures.

physics.acc-ph

SecurePose: Automated Face Blurring and Human Movement Kinematics Extraction from Videos Recorded in Clinical Settings

Movement disorder diagnosis often relies on expert evaluation of patient videos, but sharing these videos poses privacy risks. Current methods for de-identifying videos, such as blurring faces, are often manual, inconsistent, or inaccurate. Furthermore, these methods can compromise objective kinematic analysis - a crucial component of diagnosis. To address these challenges, we developed SecurePose, an open-source software that simultaneously provides reliable de-identification and automated kinematic extraction from videos recorded in clinic settings using smartphones/tablets. SecurePose utilizes pose estimation (using OpenPose) to extract full body kinematics, track individuals, identify the patient, and then accurately blur faces in the videos. We validated SecurePose on gait videos recorded in outpatient clinic visits of 116 children with cerebral palsy, assessing both the accuracy of its de-identification compared to the ground truth (manual blurring) and the reliability of the intermediate steps of kinematics extraction. Results demonstrate that SecurePose outperformed six existing methods in automated face detection and achieved comparable accuracy to robust manual blurring, but in significantly less time (91.08% faster). Ten experienced researchers also confirmed SecurePose's usability via System Usability Scale scores. These findings validate SecurePose as a practical and effective tool for protecting patient privacy while enabling accurate kinematics extraction in clinical settings.

cs.CV

Photon Calibration Performance of KAGRA during the 4th Joint Observing Run (O4)

KAGRA is a kilometer-scale cryogenic gravitational-wave (GW) detector in Japan. It joined the 4th joint observing run (O4) in May 2023 in collaboration with the Laser Interferometer GW Observatory (LIGO) in the USA, and Virgo in Italy. After one month of observations, KAGRA entered a break period to enhance its sensitivity to GWs, and it is planned to rejoin O4 before its scheduled end in October 2025. To accurately recover the information encoded in the GW signals, it is essential to properly calibrate the observed signals. We employ a photon calibration (Pcal) system as a reference signal injector to calibrate the output signals obtained from the telescope. In ideal future conditions, the uncertainty in Pcal could dominate the uncertainty in the observed data. In this paper, we present the methods used to estimate the uncertainty in the Pcal systems employed during KAGRA O4 and report an estimated system uncertainty of 0.79%, which is three times lower than the uncertainty achieved in the previous 3rd joint observing run (O3) in 2020. Additionally, we investigate the uncertainty in the Pcal laser power sensors, which had the highest impact on the Pcal uncertainty, and estimate the beam positions on the KAGRA main mirror, which had the second highest impact. The Pcal systems in KAGRA are the first fully functional calibration systems for a cryogenic GW telescope. To avoid interference with the KAGRA cryogenic systems, the Pcal systems incorporate unique features regarding their placement and the use of telephoto cameras, which can capture images of the mirror surface at almost normal incidence. As future GW telescopes, such as the Einstein Telescope, are expected to adopt cryogenic techniques, the performance of the KAGRA Pcal systems can serve as a valuable reference.

astro-ph.IM

Estimation of Newtonian noise from KAGRA cooling system

KAGRA is the first km-scale gravitational wave detector to be constructed underground and employ cryogenics to cool down its test masses. While the underground location provides a quiet site with low seismic noise, the cooling infrastructure is known to generate large mechanical vibrations due to cryocooler operation and structural resonances of the cryostat. As cooling system components are relatively heavy and in close proximity to the test masses, oscillation of gravity force induced by their vibration, so-called Newtonian noise, could contaminate the detector sensitivity. In this paper, we use the results from vibration analysis of the KAGRA cryostat to estimate cooling system Newtonian noise in the 1-100 Hz frequency band. Our calculations show that, while this noise does not limit the current detector sensitivity or inspiral range, it will be an issue in the future when KAGRA improves its sensitivity. We conclude that KAGRA may need to implement Wiener filters to subtract this noise in the future.

physics.ins-det

A laser interferometer accelerometer for vibration sensitive cryogenic experiments

Monitoring motion originating from ultra low-temperature cooling systems like cryocoolers is important for vibration sensitive cryogenic experiments like KAGRA. Since no commercial cryogenic accelerometers are available, we developed a compact self-calibrating accelerometer with a Michelson interferometer readout for cryogenic use. Change in calibration factor and drop in interferometer output originating from temperature drop were the main concerns which were tackled. Sensitivity of $3.38\times10^{-11}$ m/$\sqrt{\mathrm{Hz}}$ at 1 Hz was achieved at 300 K. The accelerometer was tested inside the KAGRA cryostat; showed stable operation down to 12 K in 0.1-100 Hz band with only 1% visibility drop. Our accelerometer can be employed in low vibration cryogenic environment for a multitude of applications.

physics.ins-det

Vibration Analysis of KAGRA Cryostat at Cryogenic Temperature

KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We performed vibration analysis of the cooling system at cryogenic temperature to study its impact on detector sensitivity. Our measurement show shield vibration below 1 Hz is not impacted by cryocooler operation or structural resonances and follows ground motion. The noise floor of the shield in 1-100 Hz was observed to be 2-3 order of magnitude larger than seismic motion even without cryocooler operation. The operation of cryocoolers does not change the noise floor, but 2.0 Hz peaks and their harmonics were observed over the entire spectrum (1-100 Hz). These results were used to calculate the coupling of cooling system vibration to the test mass. We conclude that vibration from the cooling system does not limit KAGRA design sensitivity.

physics.ins-det

Cryogenic suspension design for a kilometer-scale gravitational-wave detector

We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while keeping the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for damping control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.

physics.ins-det