SearcharxivSearch

arXiv subjects

Robert Gartmann

Publications and source records attributed to Robert Gartmann.

3 recordsLinked to original sources

CryoDE: a Digital Cryogenic Detector Emulator for Microwave SQUID Multiplexed Systems

Simultaneous readout of large-scale cryogenic detector arrays relies on multiplexing schemes such as the FDM (Frequency-Division Multiplexing) with microwave SQUID multiplexers and highly customized readout electronics. In traditional detector systems, where mixed-signal ASICs are used in detector front-ends and typically provide a digital interface, HIL (Hardware-in-the-Loop) testing can be readily implemented by reusing the existing digital logic of the front-end for emulation purposes. Such straightforward emulation is not possible for FDM low-temperature detectors, where the sensor signal is encoded in a high-frequency microwave carrier via a two-stage modulation scheme depending on the cryogenic resonators and the SQUID response. To address this challenge, we present CryoDE, a digital cryogenic-detector emulator for microwave SQUID multiplexed detector systems. CryoDE generates the encoded detector signals, including realistic pulse responses, enabling full HIL testing of the room-temperature DAQ system without requiring the cryogenic hardware. This resource-efficient FPGA-based detector twin integrates seamlessly into existing DAQ systems and allows experiment-specific adjustment of detector-signal parameters. We describe the internal architecture and capabilities of CryoDE within our custom HIL framework and demonstrate its use in evaluating the performance of real-time signal processing firmware optimized for different microwave SQUID multiplexed cryogenic-detector experiments.

physics.ins-det

Improved limit on the effective electron neutrino mass with the ECHo-1k experiment

The effective electron neutrino mass can be determined by analyzing the endpoint region of the $^{163}$Ho electron capture spectrum, provided a measurement with high energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in $^{163}$Ho collaboration, ECHo, presents an analysis of the most precise $^{163}$Ho spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of $B=9.1(1.3)\times 10^{-6}$ /eV/pixel/day was achieved allowing for a reliable analysis of the endpoint region. The derived endpoint energy $Q = 2862(4)$ eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of $Q=2863.2(6)$ eV [1]. The upper limit of the effective electron neutrino mass is improved by almost a factor 2 compared to the lowest current value [2], reaching $m_{\nu_\mathrm{e}} < 15 $ eV/c${^2}$ (90\% credible interval).

hep-ex

The spatial correlation of radiation-induced errors in superconducting devices decays over a millimeter

We perform nanosecond-resolution multiplexed readout on six same-chip superconducting microwave resonators. This allows us to pinpoint the impact positions of ionizing radiation on the chip by measuring the differential time of flight of the generated phonons, inducing correlated errors in the device, thereby implementing an on-chip seismic array. We correlate the phase response of each resonator - a proxy for the absorbed energy - to the distance from the impact point to uncover a millimetric decay length for the phonon-mediated radiation poisoning.

cond-mat.supr-con