SearcharxivSearch

arXiv subjects

Roberto Cecchi

Publications and source records attributed to Roberto Cecchi.

9 recordsLinked to original sources

Data-driven synthesis of high-fidelity triaxial magnetic waveforms for quantum control

We present a system for generating arbitrary, triaxial magnetic waveforms with a spectral content spanning from DC to tens of kHz, a critical capability for quantum control and spin manipulation. To compensate for amplifier-coil dynamics, we implement a data-driven approach to identify a numerical compensation model. The method parametrizes the system response using a Finite Impulse Response (FIR) filter calibrated on the specific waveform to be generated. The application of a driving signal designed via frequency-domain inversion of the identified model enables the synthesis of complex field sequences with sharp transitions between static and single- or multi-frequency temporal segments. The work is validated with experimental results demonstrating waveform fidelity and transient performance, thereby showcasing the precision and feasibility of the method.

physics.ins-det

In vivo validation of Wireless Power Transfer System for Magnetically Controlled Robotic Capsule Endoscopy

This paper presents the in vivo validation of an inductive wireless power transfer (WPT) system integrated for the first time into a magnetically controlled robotic capsule endoscopy platform. The proposed system enables continuous power delivery to the capsule without the need for onboard batteries, thus extending operational time and reducing size constraints. The WPT system operates through a resonant inductive coupling mechanism, based on a transmitting coil mounted on the end effector of a robotic arm that also houses an external permanent magnet and a localization coil for precise capsule manipulation. To ensure robust and stable power transmission in the presence of coil misalignment and rotation, a 3D receiving coil is integrated within the capsule. Additionally, a closed-loop adaptive control system, based on load-shift keying (LSK) modulation, dynamically adjusts the transmitted power to optimize efficiency while maintaining compliance with specific absorption rate (SAR) safety limits. The system has been extensively characterized in laboratory settings and validated through in vivo experiments using a porcine model, demonstrating reliable power transfer and effective robotic navigation in realistic gastrointestinal conditions: the average received power was 110 mW at a distance of 9 cm between the coils, with variable capsule rotation angles. The results confirm the feasibility of the proposed WPT approach for autonomous, battery-free robotic capsule endoscopy, paving the way for enhanced diagnostic in gastrointestinal medicine.

cs.RO

A Wearable Wireless Magnetic Eye-Tracker, in-vitro and in-vivo Tests

A wireless, wearable magnetic eye tracker is described and characterized. The proposed instrumentation enables simultaneous evaluation of eye and head angular displacements. Such a system can be used to determine the absolute gaze direction as well as to analyze spontaneous eye re-orientation in response to stimuli consisting in head rotations. The latter feature has implications to analyze the vestibulo-ocular reflex and constitutes an interesting opportunity to develop medical (oto-neurological) diagnostics. Details of data analysis are reported together with some results obtained in-vivo or with simple mechanical simulators that enable measurements under controlled conditions.

physics.med-ph

An innovative eye-tracker. Main features and demonstrative tests

We present a set of results obtained with an innovative eye-tracker based on magnetic dipole localization by means of an array of magnetoresistive sensors. The system tracks both head and eye movements with a high rate (100-200 Sa/s) and in real time. A simple setup is arranged to simulate head and eye motions and to test the tracker performance under realistic conditions. Multimedia material is provided to substantiate and exemplify the results. A comparison with other available technologies for eye tracking is drawn, discussing advantages (e.g. precision) and disadvantages (e.g. invasivity) of the diverse approaches, the presented method standing out for low cost, robustness and relatively low invasivity.

physics.med-ph

Validation of a fast and accurate magnetic tracker operating in the environmental field

We characterize the performance of a system based on a magnetoresistor array. This instrument is developed to map the magnetic field, and to track a dipolar magnetic source in the presence of a static homogeneous field. The position and orientation of the magnetic source with respect to the sensor frame is retrieved together with the orientation of the frame with respect to the environmental field. A nonlinear best-fit procedure is used, and its precision, time performance, and reliability are analyzed. This analysis is performed in view of the practical application for which the system is designed that is an eye-tracking diagnostics and rehabilitative tool for medical purposes, which require high speed ($\ge 100$~Sa/s) and sub-millimetric spatial resolution. A throughout investigation on the results makes it possible to list several observations, suggestions, and hints, which will be useful in the design of similar setups.

physics.app-ph

Fast, cheap, and scalable magnetic tracker with an array of magnetoresistors

We present the hardware of a cheap multi-sensor magnetometric setup where a relatively large set of magnetic field components is measured in several positions by calibrated magnetoresistive detectors. The setup is developed with the scope of mapping the (inhomogeneous) field generated by a known magnetic source, which is measured as superimposed to the (homogeneous) geomagnetic field. The final goal is to use the data produced by this hardware to reconstruct position and orientation of the magnetic source with respect to the sensor frame, simultaneously with the orientation of the frame with respect to the environmental field. Possible applications of the setup are shortly discussed, together with a synthetic description of the data elaboration and analysis.

physics.ins-det

Fast switching coil system for sample premagnetization in an unshielded ultra-low-field Nuclear Magnetic Resonance experiment

We present a system developed to premagnetize liquid samples in an ultra-low-field Nuclear Magnetic Resonance (NMR) experiment. Liquid samples of a few milliliter are exposed to a magnetic field of about 70~mT, which is abruptely switched off, so to leave a transverse microtesla field where nuclei start precessing. An accurate characterization of the transients and intermediate field level enables a reliable operation of the detection system, which is based on an optical magnetometer.

physics.ins-det

A low noise modular current source for stable magnetic field control

A low cost, stable, programmable, unipolar current source is described. The circuit is designed in view of a modular arrangement, suitable for applications where several DC sources must be controlled at once. A hybrid switching/linear design helps in improving the stability and in reducing the power dissipation and cross-talking. Multiple units can be supplied by a single DC power supply, while allowing for a variety of maximal current values and compliance voltages at the outputs. The circuit is analogically controlled by an unipolar voltage, enabling current programmability and control through commercial digital-to-analogue conversion cards.

physics.ins-det

Stray Magnetic Field Compensation with a Scalar Atomic Magnetometer

We describe a system for the compensation of time-dependent stray magnetic fields using a dual channel scalar magnetometer based on non-linear Faraday rotation in synchronously optically pumped Cs vapour. We detail the active control strategy, with an emphasis on the electronic circuitry, based on a simple phase-locked-loop integrated circuit. The performance and limits of the system developed are tested and discussed. The system was applied to significantly improve the detection of free induction decay signals from protons of remotely magnetized water precessing in an ultra-low magnetic field.

physics.ins-det