SearcharxivSearch

arXiv subjects

Robin Anthony-Petersen

Publications and source records attributed to Robin Anthony-Petersen.

3 recordsLinked to original sources

Depth Calibration of Double-sided Strip Germanium Detectors for the Compton Spectrometer and Imager Satellite

Double-sided strip high-purity germanium detectors with three-dimensional position reconstruction capability have been developed over three decades, with space-based applications in high-energy astrophysics and heliophysics. Position resolution in three dimensions is key to reconstruction of Compton scattering events, including for the upcoming Compton Spectrometer and Imager (COSI) satellite mission. Two-dimensional position reconstruction is enabled by segmentation of the two detector faces into orthogonal strip contacts, enabling a pixelized analysis. The depth of an interaction cannot be measured directly but must be inferred from the charge collection time difference between the two faces of the detector. Here, we demonstrate for the first time the depth calibration of a detector with the COSI satellite geometry read out using an application specific integrated circuit (ASIC) developed for the COSI mission. In this work, we map collection time difference to depth using the Julia-based simulation package SolidStateDetectors$.$jl and validate it with comparison to the timing distributions observed in data. We also use simulations and data to demonstrate the depth resolution on a per-pixel basis, with >90% of pixels having <0.9 mm (FWHM) resolution at 59.5 keV and <0.6 mm (FWHM) resolution at 122.1 keV.

astro-ph.IM

Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter

We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal phonon events, and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These ``singles'' are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

physics.ins-det

A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning

The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

physics.ins-det