SearcharxivSearch

arXiv subjects

Roger K. Romani

Publications and source records attributed to Roger K. Romani.

5 recordsLinked to original sources

A Transition Edge Sensor Operated in Coincidence with a High Sensitivity Athermal Phonon Sensor for Photon Coupled Rare Event Searches

Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a Transition Edge Sensor (TES) with a photon energy resolution $σ_γ= 368.4 \pm 0.4$ meV, is colocated on the same substrate as a large high sensitivity athermal phonon sensor (APS) with a phonon energy resolution $σ_\mathrm{phonon} = 701 \pm 2$ meV. We show that single 3.061 eV photons absorbed in the photon-sensing TES deposit $\sim$35\% of their energy in the electronic system of the TES, while $\sim$26\% of the photon energy leaks out of the photon-sensing TES during the downconversion process and becomes absorbed by the APS. Backgrounds, which we associate with the broadly observed ``low energy excess'' (LEE), are observed to be largely coupled to either the TES (``singles'' LEE), or phonon system, (``shared'' LEE). At high energies, these backgrounds can be efficiently discriminated from TES photon absorption events, while at low energies, their misidentification as photon events is well modeled. With significant sensitivity improvements to both the TES and APS, this coincidence technique could be used to suppress backgrounds in bosonic dark matter searches down to energies near the superconducting bandgap of the sensor.

physics.ins-det

Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter

We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal phonon events, and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These ``singles'' are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

physics.ins-det

Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors

Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously-unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids. Their understanding is essential for interpreting particle interactions at and below the eV-scale.

physics.ins-det

Aluminum Relaxation as the Source of Excess Low Energy Events in Low Threshold Calorimeters

A previously unexplained background called the Low Energy Excess (LEE) has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminium films as mediated by the motion of dislocations may account for these observations.

physics.ins-det

A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning

The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

physics.ins-det