Searcharxiv⌕ Search

arXiv subjects

Roland Koppenhöfer

Publications and source records attributed to Roland Koppenhöfer.

4 recordsLinked to original sources

Fast Timing and TCT Measurement Results of CNM Double-Sided 3D Sensors

Sensors with fast timing capabilities (on the order of tens of picoseconds) are a critical component of future HEP tracking detectors, providing the ability to disentangle high multiplicity events. Silicon 3D sensors are capable of delivering this temporal resolution and additionally display an excellent radiation hardness, suitable for the harsh environments expected in future hadron colliders (e.g. FCC-hh). In the course of the RD50 project "3D detectors optimized for timing applications", double-sided 3D sensors with two different column layouts, hexagonal and orthogonal, and different column counts were designed and produced by CNM. In this study, results of IV, top-TCT and source timing measurements of unirradiated as well as proton irradiated sensor structures are presented. The IV characterisation shows a strong decrease of the overall high leakage current of the sensors after irradiation. Top-TCT measurements with both an infrared and red laser reveal a mostly homogenous charge collection in the sensor bulk, while higher signals are observed in the outermost columns for surface charge injection. The time resolution of sensors irradiated up to a $1 \, \mathrm{MeV}$ neutron equivalent fluence of $3\times10^{15} \, \mathrm{cm^{-2}}$ reaches down to ca. $65\,\mathrm{ps}$, showing only a slight degradation compared to unirradiated sensors.

physics.ins-det↗

Characterization of Passive CMOS Strip Detectors After Proton Irradiation

Strip detectors are populating outer trackers of high-energy particle experiments. They are convenient for covering large areas of sensitive material since they use less power and have fewer readout channels compared to pixels sensors. Nevertheless, they are typically manufactured with a mask set that covers the full wafer, otherwise when using smaller reticles the strip implants have to be stitched. For this project, strip detectors were fabricated in a CMOS commercial foundry using different reticles to be stitched several times, proving the feasibility of this technology. LFoundry produced the passive CMOS strip detector with a production line of 150 nm node technology, using a 150 um thick FZ wafer. Those strip sensors have three different geometries to study different impacts of the CMOS technology. The strips have lengths of 2.1 cm and 4.1 cm, stitching 3 or 5 reticles respectively. This work shows results of 24 GeV proton irradiated passive CMOS strip detectors. The detectors were irradiated at CERN and were tested with different set-ups, not showing any effect from the strips stitching. Proving that this technology is feasible for detecting high-energy particles opens the door to future large productions of passive strip detectors and also to produce active strip sensors in commercial CMOS foundries.

physics.ins-det↗

Characterisation and simulation of stitched CMOS strip sensors

In high-energy physics, there is a need to investigate alternative silicon sensor concepts that offer cost-efficient, large-area coverage. Sensors based on CMOS imaging technology present such a silicon sensor concept for tracking detectors. The CMOS Strips project investigates passive CMOS strip sensors fabricated by LFoundry in a 150nm technology. By employing the technique of stitching, two different strip sensor formats have been realised. The sensor performance is characterised based on measurements at the DESY II Test Beam Facility. The sensor response was simulated utilising Monte Carlo methods and electric fields provided by TCAD device simulations. This study shows that employing the stitching technique does not affect the hit detection efficiency. A first look at the electric field within the sensor and its impact on generated charge carriers is being discussed.

physics.ins-det↗

A Beam Monitor for Ion Beam Therapy based on HV-CMOS Pixel Detectors

Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth dependent energy deposition, which can be exploited to accurately deposit dose in the tumor cells. To guarantee this, high accuracy of monitoring and control of the particle beam is of utmost importance. Before the particle beam enters the patient, it traverses a monitoring system which has to give fast feedback to the beam control system on position and dose rate of the beam while minimally interacting with the beam. The multi-wire chambers mostly used as beam position monitor have their limitations when fast response time is required (drift time). Future developments like MRI-guided ion beam therapy pose additional challenges for the beam monitoring system like tolerance of magnetic fields and acoustic noise (vibrations). Solid-state detectors promise to overcome these limitations and the higher resolution they offer can create additional benefits. This article presents the evaluation of an HV-CMOS detector for beam monitoring, provides results from feasibility studies in a therapeutic beam and summarizes the concepts towards the final large-scale assembly and readout system.

physics.med-ph↗