Searcharxiv⌕ Search

arXiv subjects

Rolf F. Schulte

Publications and source records attributed to Rolf F. Schulte.

2 recordsLinked to original sources

Highly accelerated 3D Cartesian MPnRAGE with implicit neural representation reconstruction

MPnRAGE enables multiple inversion contrast images in a single scan, allowing quantitative T1 mapping, tissue nulled contrasts, and standard MPRAGE synthesis. However, current 3D scan times remain clinically impractical, motivating accelerated 3D MPnRAGE. This work provides a highly accelerated Cartesian 3D MPnRAGE sequence with joint implicit neural representation (INR) reconstruction. The sequence uses a tailored view-ordering strategy, flip angle schedule and complementary variable-density Poisson-disk undersampling. Calibration data acquired during otherwise unused delay time are used for sensitivity map estimation and complementary high-frequency sampling. Ten INR-reconstructed inversion images at 1.5 mm$^3$ are evaluated against fully sampled references via retrospective undersampling. Prospectively accelerated 1 mm$^3$ images at R = 20 (5.39 min) demonstrate clinical feasibility. INR reconstruction outperforms subspace and iterative local low rank reconstruction on highly accelerated data. The proposed highly undersampled 3D Cartesian MPnRAGE with INR reconstruction generates multiple high-quality inversion contrasts in substantially reduced scan time. Scan-specific INR reconstruction improves image quality while reducing reconstruction time versus state-of-the-art methods.

eess.IV↗

Rapid three-dimensional multiparametric MRI with quantitative transient-state imaging

Novel methods for quantitative, transient-state multiparametric imaging are increasingly being demonstrated for assessment of disease and treatment efficacy. Here, we build on these by assessing the most common Non-Cartesian readout trajectories (2D/3D radials and spirals), demonstrating efficient anti-aliasing with a k-space view-sharing technique, and proposing novel methods for parameter inference with neural networks that incorporate the estimation of proton density. Our results show good agreement with gold standard and phantom references for all readout trajectories at 1.5T and 3T. Parameters inferred with the neural network were within 6.58% difference from the parameters inferred with a high-resolution dictionary. Concordance correlation coefficients were above 0.92 and the normalized root mean squared error ranged between 4.2% - 12.7% with respect to gold-standard phantom references for T1 and T2. In vivo acquisitions demonstrate sub-millimetric isotropic resolution in under five minutes with reconstruction and inference times < 7 minutes. Our 3D quantitative transient-state imaging approach could enable high-resolution multiparametric tissue quantification within clinically acceptable acquisition and reconstruction times.

physics.med-ph↗