SearcharxivSearch

arXiv subjects

Roman Y. Shopa

Publications and source records attributed to Roman Y. Shopa.

7 recordsLinked to original sources

A systematic evaluation of machine learning classifiers for event-by-event background rejection in LAFOV PET scanners

The introduction of LAFOV PET scanners brings significant sensitivity gains but also a substantial increase in the background rate from accidental coincidences, phantom-scattered and detector-scattered photons. While machine learning methods have been applied to background reduction in PET imaging, they target specific background components in post-processing rather than event-by-event classification on the raw data. In this work, we formulate coincidence classification as a supervised multi-class problem and evaluate XGBoost, AdaBoost and Neural Network classifiers as pre-reconstruction filters, using Monte Carlo simulations of the Siemens Biograph Vision Quadra scanner with NEMA IEC and anthropomorphic XCAT phantoms. We investigate two feature sets: a 4-feature representation based on the Attenuation Factor, photon time difference, energy sum, and energy difference, and an extended 6-feature set that incorporates topology-based variables. A systematic robustness study via cross-phantom inference reveals that the 4-feature models generalise significantly better across different phantom geometries, with XGBoost suffering an accuracy loss of only 0.04 compared to 0.13 for the 6-feature variant. Our best models achieve accuracies of up to 0.74 and 0.69 for the NEMA IEC and XCAT phantoms, respectively, outperforming traditional geometry-based cuts. However, we show that this compact feature set not only provides limited suppression of in-phantom scattered coincidences, but it also can lead to non-trivial spatial patterns. With scattered coincidences being the dominant background component in clinical conditions, this suggests that while the method serves as an effective and geometry-agnostic replacement for traditional cut-based selection, meaningful further gains in image quality will require either larger input representations or dedicated treatment of the phantom-scattered component.

cs.CV

A Monte Carlo positronium decay source model with multiple annihilation channels in GATE

Positronium-based imaging requires realistic modelling of positronium (Ps) decay in matter. We introduce a modular Ps decay model implemented in GATE 9.4 and GATE 10, enabling the definition of an arbitrary number of decay channels characterised by lifetime, branching fraction, annihilation multiplicity (2g/3g), and optional prompt photon emission. The model is validated through analytical and numerical benchmarks, including lifetime distributions, branching fraction consistency, photon kinematics, and prompt photon emission. Its practical applicability is demonstrated using simulations of mixed annihilation scenarios and the NEMA IEC phantom with a large field-of-view PET system. The proposed model accurately reproduces input lifetime distributions as weighted sums of exponential components and correctly samples decay channel fractions. Simulated two- and three-photon annihilation kinematics are consistent with theoretical expectations. Complex mixtures of decay channels, including varying 3g-to-2g ratios and multi-component ortho-positronium lifetimes, are correctly modelled, with observable signatures reflected in both temporal and energy distributions. Phantom simulations demonstrate the capability to generate realistic positronium-sensitive datasets. This work provides the first general-purpose, multi-channel positronium decay model integrated into GATE, enabling realistic simulations of positronium behaviour in complex media. The model supports the development and optimisation of positronium-based imaging techniques, including PLI and multi-photon PET, and applies to medical imaging, industrial tomography, and fundamental physics studies. Its public availability and compatibility with standard GATE workflows make it a valuable tool for the broader research community.

physics.med-ph

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.

physics.med-ph

Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

hep-ph

Multi-photon time-of-flight MLEM application for the positronium imaging in J-PET

We develop a positronium imaging method for the Jagiellonian PET (J-PET) scanners based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM). The system matrix elements are calculated on-the-fly for the coincidences comprising two annihilation and one de-excitation photons that originate from the ortho-positronium (o-Ps) decay. Using the Geant4 library, a Monte Carlo simulation was conducted for four cylindrical 22Na sources of beta plus decay with diverse o-Ps mean lifetimes, placed symmetrically inside the two JPET prototypes. The estimated time differences between the annihilation and the positron emission were aggregated into histograms (one per voxel), updated by the weights of the activities reconstructed by TOF MLEM. The simulations were restricted to include only the o-Ps decays into back-to-back photons, allowing a linear fitting model to be employed for the estimation of the mean lifetime from each histogram built in the log scale. To suppress the noise, the exclusion of voxels with activity below 2-10 percent of the peak was studied. The estimated o-Ps mean lifetimes were consistent with the simulation and distributed quasi-uniformly at high MLEM iterations. The proposed positronium imaging technique can be further upgraded to include various correction factors, as well as be modified according to realistic o-Ps decay models.

physics.ins-det

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph

Positronium imaging with the novel multiphoton PET scanner

In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.

physics.med-ph