Searcharxiv⌕ Search

arXiv subjects

Ronan M. G. Berg

Publications and source records attributed to Ronan M. G. Berg.

2 recordsLinked to original sources

Ventilation Perfusion Functional Difference Images in Lung SPECT: a linear and symmetrical scale as an alternative to the Ventilation Perfusion Ratio

Purpose: Ventilation Perfusion SPECT is important in the diagnostics of e.g. pulmonary embolism and chronic obstructive pulmonary disease. Classical and reverse mismatched defects can be identified by utilizing the ventilation-perfusion ratio. Unfortunately, this ratio is only linear in the ventilation, the scale is not symmetrical regarding classical and reversed mismatches and small perfusion values give rise to artifacts. The ventilation-perfusion (VQ) difference is developed as an alternative. Methods: For both VQ-ratio and VQ-difference a scaling factor for the perfusion is computed, so that voxels with matched ventilation and perfusion (on average) yield zero signal. The relative VQ-difference is calculated by scaling with the summed VQ-signal in each voxel. The scaled VQ-difference is calculated by scaling with the global maximum of this sum. Results: The relative and scaled differences have a scale from -1 (perfusion only) to +1 (ventilation only). Image quality of relative VQ-difference and VQ-ratio images is hampered by artifacts from areas with both low perfusion and low ventilation. Ratio and differences have been investigated in ten patients and are shown for three patients (one without defects). Clinical thresholds for the difference images are derived resulting in color maps of relevant (reversed) mismatches with a (reciprocal) ratio larger than two. Conclusions: The relative ventilation-perfusion difference is a methodological improvement on the ventilation-perfusion ratio, because it has a symmetrical scale and is bound on a closed domain. A better diagnostic value is expected by utilizing the scaled difference, which represents functional difference instead of relative difference.

physics.med-ph↗

Characterization of differences in immune responses during bolus and continuous infusion endotoxin challenges using mathematical modeling

Endotoxin administration is commonly used to study the inflammatory response, and though traditionally given as a bolus injection, it can be administered as a continuous infusion over multiple hours. Several studies hypothesize that the latter better represents the prolonged and pronounced inflammation observed in conditions like sepsis. Yet, very few experimental studies have administered endotoxin using both strategies, leaving significant gaps in determining the underlying mechanisms responsible for their differing immune responses. We use mathematical modeling to analyze cytokine data from two studies administering a 2 ng/kg dose of endotoxin, one as a bolus and the other as a continuous infusion over four hours. Using our model, we simulate the dynamics of mean and subject-specific cytokine responses as well as the response to long-term endotoxin administration. Cytokine measurements reveal that the bolus injection leads to significantly higher peaks for IL-8, while IL-10 reaches significantly higher peaks during continuous administration. Moreover, the peak timing of all measured cytokines occurs later in the continuous infusion. We identify three model parameters that significantly differ between the two administration methods. Monocyte activation of IL-10 is greater during the continuous infusion, while recovery rates of IL-8 is faster for the bolus injection. This suggests that a continuous infusion elicits a stronger, longer-lasting systemic reaction through increased stimulation of monocyte anti-inflammatory mediator production and decreased recovery of pro-inflammatory catalysts. Furthermore, our continuous infusion model exhibits prolonged inflammation with recurrent peaks resolving within two days during long-term (20-32 hours) endotoxin administration.

q-bio.TO↗