SearcharxivSearch

arXiv subjects

Rui-Jiu Chen

Publications and source records attributed to Rui-Jiu Chen.

4 recordsLinked to original sources

Precision masses of neutron-rich platinum and gold nuclei reveal enhanced $N=126$ shell strength below doubly-magic $^{208}$Pb

The heaviest stable nuclei in the universe owe their existence to quantum shell structure, the grouping of protons and neutrons into discrete energy levels separated by gaps. The largest known neutron shell gap in stable nuclei, at $N=126$, stabilizes doubly-magic $^{208}$Pb and is responsible for the characteristic abundance peak of heavy elements near gold and platinum produced by the rapid neutron-capture process (r-process). Whether this shell gap persists as protons are removed from lead is a question central to both nuclear structure and the modeling of heavy-element synthesis, yet it has remained unanswered due to the extraordinary difficulty of producing the relevant neutron-rich nuclei. Direct experimental knowledge in this region was essentially absent. Here we report the first precision mass measurements of $^{203,204}$Pt and $^{204,205,206}$Au, performed at GSI using a novel combination of Schottky and isochronous mass spectrometry in a heavy-ion storage ring. The $N=126$ isotones $^{204}$Pt and $^{205}$Au are more strongly bound than the extrapolated trend of the previously known mass surface by 403 and 464~keV, respectively, revealing an unexpectedly enhanced $N=126$ shell strength below doubly-magic $^{208}$Pb. Furthermore, the proton-neutron interaction strength exhibits a hitherto unobserved bifurcation at $N=126$ as protons are removed from $^{208}$Pb. Our results redefine the nuclear mass surface in the neutron-rich heavy-element region and provide direct experimental benchmarks for theoretical models whose extrapolations toward more exotic nuclei are essential for r-process nucleosynthesis calculations.

nucl-ex

Charge resolution in the isochronous mass spectrometry and the mass of $^{51}$Co

Isochronous mass spectrometry (IMS) of heavyion storage rings is a powerful tool for the mass measurements of short-lived nuclei. In IMS experiments, masses are determined through precision measurements of the revolution times of the ions stored in the ring. However, the revolution times cannot be resolved for particles with nearly the same mass-to-charge (m/q) ratios. To overcome this limitation and to extract the accurate revolution times for such pairs of ion species with very close m/q ratios, in our early work on particle identification, we analyzed the amplitudes of the timing signals from the detector based on the emission of secondary electrons. Here, the previous data analysis method is further improved by considering the signal amplitudes, detection efficiencies, and number of stored ions in the ring. A sensitive Z-dependent parameter is introduced in the data analysis, leading to a better resolution of $^{34}$Ar$^{18+}$ and $^{51}$Co$^{27+}$ with A/Z=17/9. The mean revolution times of $^{34}$Ar$^{18+}$ and $^{51}$Co$^{27+}$ are deduced, although their time difference is merely 1.8 ps. The uncorrected, overlapped peak of these ions has a full width at half maximum of 7.7 ps. The mass excess of $^{51}$Co was determined to be -27332(41) keV, which is in agreement with the previous value of -27342(48) keV.

nucl-ex

Characterization of a double Time-Of-Flight detector system for accurate velocity measurement in a storage ring using laser beams

The Isochronous Mass Spectrometry (IMS) is a powerful tool for mass measurements of exotic nuclei with half-lives as short as several tens of micro-seconds in storage rings. In order to improve the mass resolving power while preserving the acceptance of the storage ring, the IMS with two Time-Of-Flight (TOF) detectors has been implemented at the storage ring CSRe in Lanzhou, China. Additional velocity information beside the revolution time in the ring can be obtained for each of the stored ions by using the double TOF detector system. In this paper, we introduced a new method of using a 658 nm laser range finder and a short-pulsed ultra-violet laser to directly measure the distance and time delay difference between the two TOF detectors which were installed inside the $10^{-11}$ mbar vacuum chambers. The results showed that the distance between the two ultra-thin carbon foils of the two TOF detectors was ranging from 18032.5 mm to 18035.0 mm over a measurable area of 20$\times$20 mm$^2$. Given the measured distance, the time delay difference which comes with signal cable length difference between the two TOF detectors was measured to be $Δt_{delay1-2}=99$(26) ps. The new method has enabled us to use the speed of light in vacuum to calibrate the velocity of stored ions in the ring. The velocity resolution of the current double TOF detector system at CSRe was deduced to be $σ(v)/v=4.4\times 10^{-4}$ for laser light, mainly limited by the time resolution of the TOF detectors.

physics.ins-det

A data analysis method for isochronous mass spectrometry using two time-of-flight detectors at CSRe

The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in detail. Recently, two TOF detectors have been installed at CSRe and the new working mode of the ring is under test. In this paper, a data analysis method for this mode is introduced and tested with a series of simulations. The results show that the new IMS method can significantly improve mass resolving power via the additional velocity information of stored ions. This improvement is especially important for nuclides with Lorentz factor $γ$-value far away from the transition point $γ_t$ of the storage ring CSRe.

physics.ins-det