Reducing Spectral Oscillations for Robust Reference Frequency-Based Ultrasound Attenuation Estimation in Harmonic Imaging

Ultrasound attenuation coefficient estimation (ACE) has emerged as a quantitative imaging biomarker for noninvasive assessment of hepatic steatosis. A system-independent technique based on spectral normalization, known as the reference frequency method (RFM), was previously proposed to estimate ACE without requiring a well-calibrated reference phantom. Furthermore, incorporating harmonic imaging can significantly suppress reverberation signals. In previous clinical study, RFM has achieved high correlation with MRI-PDFF, demonstrating its potential for clinical application. However, a major challenge of RFM is the presence of oscillations in the frequency power-ratio decay curves (FPDCs), which can distort the linear fitting used to estimate the attenuation coefficient and consequently degrade ACE accuracy. These oscillations arise from constructive and destructive interference among backscattered echoes, resulting in oscillatory fluctuations in the measured power spectrum that propagate into the FPDCs. We propose a transmission scheme combining multiple frequencies and steering angles to mitigate oscillations in the FPDCs. Averaging these FPDCs suppresses the interference-induced oscillations while preserving the attenuation-dependent decay trend, thereby improving linearity and the accuracy of ACE results. In in-vitro experiments using calibrated phantoms (0.5 and 0.76 dB/cm/MHz) demonstrated that the proposed method improved FPDC linearity and ACE accuracy, achieving an R2 of 0.99 and attenuation coefficient estimates of 0.51 and 0.77 dB/cm/MHz, versus an R2 of 0.89 and estimates of 0.56 and 0.70 dB/cm/MHz for conventional RFM. The proposed method also demonstrated superior performance in a pilot patient study (n=15), achieving a stronger correlation with MRI-PDFF (R = 0.89 vs. 0.83) while reducing inter-measurement variability, indicating improved robustness and clinical potential.

physics.med-ph

Super-Resolution Posterior Ocular Microvascular Imaging Using 3-D Ultrasound Localization Microscopy With a 32X32 Matrix Array

The purpose of this study is to enable in-vivo three-dimensional (3-D) ultrasound localization microscopy (ULM) of posterior ocular microvasculature using a 256-channel system and a 1024-element matrix array, and to overcome limitations of restricted transmit angles, sound speed mismatch caused by the crystalline lens and surrounding tissues, and the low signal-to-noise ratio (SNR) of microbubble signals. To address phase distortions from the crystalline lens, which has a higher speed of sound (SOS) than surrounding tissues, a region-dependent SOS beamforming approach was implemented to improve microbubble resolution. A 4-D non-local means filter was subsequently applied to suppress background noise and enhance microbubble contrast. The proposed method improved localization accuracy and image quality, achieving a spatial resolution of 63 um, while Fourier shell correlation (1/2-bit threshold) confirmed a global resolution of approximately 59 um. Higher mean normalized cross-correlation coefficients between the microbubbles and the system point-spread function, obtained with the proposed method (approximately 0.67), compared with those without the proposed method (approximately 0.60), indicate enhanced microbubble signal quality. Furthermore, the 3-D bi-directional vessel density and flow-velocity maps were reconstructed, capturing detailed choroidal vascular and hemodynamic patterns. These results demonstrate that region-dependent SOS beamforming combined with spatiotemporal denoising enables high-resolution posterior ocular ULM and provides a practical pathway toward quantitative 3-D assessment of retinal and choroidal microvasculature for potential clinical use.

physics.med-ph

Fast 3D Ultrasound Localization Microscopy via Projection-based Processing Framework

Three-dimensional ultrasound localization microscopy (ULM) enables comprehensive visualization of the vasculature, thereby improving diagnostic reliability. Nevertheless, its clinical translation remains challenging, as the exponential growth in voxel count for full 3D reconstruction imposes heavy computational demands and extensive post-processing time. In this row-column array (RCA)-based 3D in vivo pig kidney ULM study, we reformulate each step of the full 3D ULM pipeline, including beamforming, clutter filtering, motion estimation, microbubble separation and localization into a series of computational-efficient 2D operations, substantially reducing the number of voxels to be processed while maintaining comparable accuracy. The proposed framework reconstructs each 0.75-s ensemble acquired at frame rate of 400 Hz, covering a 25*27.4*27.4 mm3 volume, in 0.52 s (70% of the acquisition time) on a single RTX A6000 Ada GPU, while maintaining ULM image quality comparable to conventional 3D processing. Quantitatively, it achieves a structural similarity index (SSIM) of 0.93 between density maps and a voxel-wise velocity agreement with slope of 0.93 and R2 = 0.88, closely matching conventional 3D results, and for the first time, demonstrating potential for real-time feedback during scanning, which could improve robustness, reduce operator dependence and accelerate clinical workflows.

physics.med-ph

Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging

Objective: Hyper-clutter artifacts (HCA), arising from strong tissue reflections or physiological motion, present persistent challenges in ultrafast ultrasound Doppler imaging, often obscuring surrounding small vessel flow signals, especially in fascial regions such as the renal capsule. This study proposes U-profile-based decluttering (UPBD), a robust and computationally efficient method that exploits singular value decomposition (SVD)-derived spatial singular vectors to suppress HCA in ultrafast Doppler imaging. Methods: UPBD analyzes intensity profile of each pixel along the singular-order dimension of the SVD-derived left singular vectors U. A pixel-wise clutter-energy ratio is computed to derive a spatially adaptive declutter weighting map, which is applied to the SVD-filtered flow signals. Results: UPBD was evaluated on multiple in vivo datasets. Quantitative assessments based on contrast-to-noise ratio (CNR) and contrast-to-tissue ratio (CTR) demonstrated significant improvements over conventional SVD filtering. For example, UPBD enhanced CTR from 7.3 dB to 21.7 dB in contrast-free pig kidney, 17.8 dB to 42.1 dB in contrast-enhanced pig kidney, 8.2 dB to 32.8 dB in human kidney, and -4.9 dB to 3.7 dB in 3D human liver. Conclusion: The proposed UPBD method effectively suppresses HCA while preserving blood flow signals with minimal extra computational cost and no need for extensive parameter tuning. Significance: UPBD serves as a lightweight, easily integrated post-processing method that enhances HCA suppression, enabling broader application of SVD-based ultrafast Doppler imaging.

physics.med-ph

Self-supervised Deep Learning for Denoising in Ultrasound Microvascular Imaging

Ultrasound microvascular imaging (UMI) is often hindered by low signal-to-noise ratio (SNR), especially in contrast-free or deep tissue scenarios, which impairs subsequent vascular quantification and reliable disease diagnosis. To address this challenge, we propose Half-Angle-to-Half-Angle (HA2HA), a self-supervised denoising framework specifically designed for UMI. HA2HA constructs training pairs from complementary angular subsets of beamformed radio-frequency (RF) blood flow data, across which vascular signals remain consistent while noise varies. HA2HA was trained using in-vivo contrast-free pig kidney data and validated across diverse datasets, including contrast-free and contrast-enhanced data from pig kidneys, as well as human liver and kidney. An improvement exceeding 15 dB in both contrast-to-noise ratio (CNR) and SNR was observed, indicating a substantial enhancement in image quality. In addition to power Doppler imaging, denoising directly in the RF domain is also beneficial for other downstream processing such as color Doppler imaging (CDI). CDI results of human liver derived from the HA2HA-denoised signals exhibited improved microvascular flow visualization, with a suppressed noisy background. HA2HA offers a label-free, generalizable, and clinically applicable solution for robust vascular imaging in both contrast-free and contrast-enhanced UMI.

eess.IV

Quantitative sub-resolution blood velocity estimation using ultrasound localization microscopy ex-vivo and in-vivo

Super-resolution ultrasound imaging relies on the sub-wavelength localization of microbubble contrast agents. By tracking individual microbubbles, the velocity and flow within microvessels can be estimated. However, a 2D super-resolution image can only localize bubbles with sub-wavelength resolution in the imaging plane whereas the resolution in the elevation plane is limited by conventional beamwidth physics. Since ultrasound imaging integrates echoes over the elevation dimension, velocity estimates at a single location in the imaging plane include information throughout the imaging slice thickness. This slice thickness is typically a few orders or magnitude larger than the super-resolution limit. It is shown here that in order to estimate the velocity, a spatial integration over the elevation direction must be considered. This operation yields a multiplicative correction factor that compensates for the elevation integration. A correlation-based velocity estimation technique is then presented. Calibrated microtube phantom experiments are used to validate the proposed velocity estimation method and the proposed elevation integration correction factor. It is shown that velocity measurements are in agreement with theoretical predictions within the considered range of flow rates (10 to 90 $μ$L/min). Then, the proposed technique is applied to two in-vivo mouse tail experiments imaged with a low frequency human clinical transducer with human clinical concentrations of microbubbles. In the first experiment, a vein was visible with a diameter of 140 $μ$m and a peak flow velocity of 0.8 mm/s. In the second experiment, a vein was observed in the super-resolved image with a diameter of 120~$μ$m and with maximum local velocity of $\approx$~4.4~mm/s. It is shown that the parabolic flow profiles within these micro-vessels are resolvable.

physics.med-ph