SearcharxivSearch

arXiv subjects

Ryne Didier

Publications and source records attributed to Ryne Didier.

2 recordsLinked to original sources

Atlas-Assisted Segment Anything Model for Fetal Brain MRI (FeTal-SAM)

This paper presents FeTal-SAM, a novel adaptation of the Segment Anything Model (SAM) tailored for fetal brain MRI segmentation. Traditional deep learning methods often require large annotated datasets for a fixed set of labels, making them inflexible when clinical or research needs change. By integrating atlas-based prompts and foundation-model principles, FeTal-SAM addresses two key limitations in fetal brain MRI segmentation: (1) the need to retrain models for varying label definitions, and (2) the lack of insight into whether segmentations are driven by genuine image contrast or by learned spatial priors. We leverage multi-atlas registration to generate spatially aligned label templates that serve as dense prompts, alongside a bounding-box prompt, for SAM's segmentation decoder. This strategy enables binary segmentation on a per-structure basis, which is subsequently fused to reconstruct the full 3D segmentation volumes. Evaluations on two datasets, the dHCP dataset and an in-house dataset demonstrate FeTal-SAM's robust performance across gestational ages. Notably, it achieves Dice scores comparable to state-of-the-art baselines which were trained for each dataset and label definition for well-contrasted structures like cortical plate and cerebellum, while maintaining the flexibility to segment any user-specified anatomy. Although slightly lower accuracy is observed for subtle, low-contrast structures (e.g., hippocampus, amygdala), our results highlight FeTal-SAM's potential to serve as a general-purpose segmentation model without exhaustive retraining. This method thus constitutes a promising step toward clinically adaptable fetal brain MRI analysis tools.

cs.CV

Rapid, High-resolution and Distortion-free $R_{2}^{*}$ Mapping of Fetal Brain using Multi-echo Radial FLASH and Model-based Reconstruction

Purpose: To develop a rapid, high-resolution and distortion-free technique for simultaneous water-fat separation, $R_{2}^{*}$ and $B_{0}$ mapping of the fetal brain at 3T. Methods: A 2D multi-echo radial FLASH sequence with blip gradients is adapted for data acquisition during maternal free breathing. A calibrationless model-based reconstruction with sparsity constraints is developed to jointly estimate water, fat, $R_{2}^{*}$ and $B_{0}$ field maps directly from k-space. This approach was validated and compared to reference methods using numerical and NIST phantoms and data from nine fetuses between 26 and 36 weeks of gestation age. Results: Both numerical and experimental phantom studies confirm good accuracy and precision. In fetal studies, model-based reconstruction yields quantitative $R_{2}^{*}$ values in close agreement with those from a parallel imaging compressed sensing (PICS) technique using Graph Cut (intra-class correlation coefficient [ICC] = 0.9601), while providing enhanced image detail. Repeated scans confirm good reproducibility (ICC = 0.9213). Compared to multi-echo EPI, the proposed radial technique produces higher-resolution (1.1 $\times$ 1.1 $\times$ 3 mm$^{3}$ vs. 2-3 $\times$ 2-3 $\times$ 3 mm$^{3}$) $R_{2}^{*}$ maps with reduced distortion. Despite of differences in motion, resolution and distortion, $R_{2}^{*}$ values are comparable between the two acquisition strategies (ICC = 0.8049). Additionally, the proposed approach enables synthesis of high-resolution and distortion-free $R_{2}^{*}$-weighted images. Conclusion: This study demonstrates the feasibility of using multi-echo radial FLASH combined with calibrationless model-based reconstruction for motion-robust, distortion-free $R_{2}^{*}$ mapping of the fetal brain at 3T, achieving a nominal resolution of $1.1 \times 1.1 \times 3$ mm$^{3}$ within 2 seconds per slice.

physics.med-ph