Rapid, high-sensitivity detection of biomolecules using dual-comb biosensing: application to the SARS-CoV-2 nucleocapsid protein

Rapid, sensitive detection of biomolecules is important for improved testing methods for viruses as well as biomarkers and environmental hormones. For example, testing for SARS-CoV-2 is essential in the fight against the COVID-19 pandemic. Reverse-transcription polymerase chain reaction (RT-PCR) is the current standard for COVID-19 testing; however, it is hampered by the long testing process. Shortening the testing process while achieving high sensitivity would facilitate sooner quarantine and thus presumably prevention of the spread of SARS-CoV-2. Here, we aim to achieve rapid, sensitive detection of the SARS-CoV-2 nucleocapsid protein by enhancing the performance of optical biosensing with a dual-comb configuration of optical frequency combs. The virus-concentration-dependent optical spectrum shift is transformed into a photonic RF shift by frequency conversion between the optical and RF regions, facilitating mature electrical frequency measurements. Furthermore, active-dummy temperature-drift compensation enables very small changes in the virus-concentration-dependent signal to be extracted from the large, variable background signal. This dual-comb biosensing technique has the potential to reduce the COVID-19 testing time to 10 min while maintaining sensitivity close to that of RT-PCR. Furthermore, this system can be applied for sensing of not only viruses but also various biomolecules for clinical diagnosis, health care, and environmental monitoring.

q-bio.QM

Scan-less full-field fluorescence-lifetime dual-comb microscopy using two-dimensional spectral mapping and frequency multiplexing of dual-optical-comb beats

Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool for quantitative fluorescence imaging because fluorescence lifetime is independent of concentration of fluorescent molecules or excitation/detection efficiency and is robust to photobleaching. However, since FLIM is based on point-to-point measurements, mechanical scanning of a focal spot is needed for forming an image, which hampers rapid imaging. In this article, we demonstrate scan-less full-field FLIM based on a one-to-one correspondence between two-dimensional (2D) image pixels and frequency-multiplexed RF signals. A vast number of dual-optical-comb beats between dual optical frequency combs is effectively adopted for 2D spectral mapping and high-density frequency multiplexing in radio-frequency region. Bimodal images of fluorescence amplitude and lifetime are obtained with high quantitativeness from amplitude and phase spectra of fluorescence RF comb modes without the need for mechanical scanning. The proposed method will be useful for rapid quantitative fluorescence imaging in life science.

physics.optics

Optical image amplification in dual-comb microscopy by use of optical-fiber-amplified interferogram

Dual-comb microscopy (DCM), based on a combination of dual-comb spectroscopy (DCS) with two-dimensional spectral encoding (2D-SE), is a promising method for scan-less confocal laser microscopy giving an amplitude and phase image contrast with the confocality. However, signal loss in a 2D-SE optical system hampers increase in image acquisition rate due to decreased signa-to-noise ratio. In this article, we demonstrated optical image amplification in DCM with an erbium-doped fiber amplifier (EDFA). Combined use of image-encoded DCS interferogram and EDFA benefits from not only the batch amplification of amplitude and phase images but also significant rejection of amplified spontaneous emission (ASE) background. Effectiveness of the optical-image-amplified DCM is highlighted in the single-shot quantitative nanometer-order surface topography and the real-time movie of polystyrene beads dynamics under water convection. The proposed method will be a powerful tool for real-time observation of surface topography and fast dynamic phenomena.

physics.optics

Refractive index sensing with temperature compensation by a multimode-interference fiber-based optical frequency comb sensing cavity

We proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity employing a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength shift of the OFC. We realized the simultaneous and continuous measurement of RI-related concentration of a liquid sample and its temperature with precisions of 1.6*10^-4 RIU and 0.08 degree. The proposed method would be a useful means for the various applications based on RI sensing.

physics.app-ph

Lock-in-detection dual-comb spectroscopy

Dual-comb spectroscopy (DCS) is useful for gas spectroscopy due to high potential of optical frequency comb (OFC). However, fast Fourier transform (FFT) calculation of a huge amount of temporal data spends significantly longer time than the acquisition time of an interferogram. In this article, we demonstrate frequency-domain DCS by a combination of DCS with lock-in detection, namely LID-DCS. LID-DCS directly extracts an arbitrary OFC mode from a vast number of OFC modes without the need for FFT calculation. Usefulness of LID-DCS is demonstrated in rapid monitoring of transient signal change and spectroscopy of hydrogen cyanide gas.

physics.optics

Multicascade-linked synthetic wavelength digital holography using an optical-comb-referenced frequency synthesizer

Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrapping ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., synthetic wavelength DH, can expand the axial range up to a few tens of microns, this method is still insufficient for practical applications. In this article, a tunable external cavity laser diode phase-locked to an optical frequency comb, namely, an optical-comb-referenced frequency synthesizer, is effectively used for multiple synthetic wavelengths within the range of 32 um to 1.20 m. A multiple cascade link of the phase images among an optical wavelength (= 1.520 um) and 5 different synthetic wavelengths (= 32.39 um, 99.98 um, 400.0 um, 1003 um, and 4021 um) enables the shape measurement of a reflective millimeter-sized stepped surface with the axial resolution of 34 nm. The axial dynamic range, defined as the ratio of the maximum axial range (= 0.60 m) to the axial resolution (= 34 nm), achieves 1.7*10^8, which is much larger than that of previous synthetic wavelength DH. Such a wide axial dynamic range capability will further expand the application field of DH for large objects with meter dimensions.

physics.app-ph

Dual terahertz comb spectroscopy with a single free-running fibre laser

Dual THz comb spectroscopy has the potential to be used as universal THz spectroscopy with high spectral resolution, high spectral accuracy, and broad spectral coverage; however, the requirement for dual stabilized femtosecond lasers hampers its versatility due to the bulky size, high complexity, and high cost. We here report the first demonstration of dual THz comb spectroscopy using a single free-running fibre laser. By tuning the cavity-loss-dependent gain profile with an intracavity Lyot filter together with precise management of the cavity length and dispersion, dual-wavelength pulsed light beams with slightly detuned repetition frequencies are generated in a single laser cavity. Due to sharing of the same cavity, such pulsed light beams suffer from common-mode fluctuation of the repetition frequency, and hence the corresponding frequency difference between them is passively stable around a few hundred hertz within millihertz fluctuation. This considerably stable frequency difference enables dual THz comb spectroscopy with a single free-running fibre laser. While greatly reducing the size, complexity, and cost of the laser source by use of a single free-running fibre laser, the dual THz comb spectroscopy system maintains a spectral bandwidth and dynamic range of spectral power comparable to a system equipped with dual stabilized fibre lasers, and can be effectively applied to high-precision spectroscopy of acetonitrile gas at atmospheric pressure. The demonstrated results indicate that this system is an attractive solution for practical applications of not only THz spectroscopy but also THz-pulse-based measurements.

physics.ins-det