SearcharxivSearch

arXiv subjects

Ryosuke Ota

Publications and source records attributed to Ryosuke Ota.

14 recordsLinked to original sources

108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations

Objective. Existing commercial time-of-flight positron emission tomography (TOF-PET) systems yield a coincidence time resolution (CTR) of ~200 ps or less full width at half maximum (FWHM). Recently, there has been a challenge to achieve a CTR of 100 ps FWHM at the system level. However, current silicon photomultipliers (SiPMs) and 20-mm-thick scintillators in conventional single-ended readout scheme is difficult to achieve 100 ps CTR; the photon transport time spread (PTS) within the scintillator crystal is a major barrier. Differences in the interaction position result in variations in PTS on the order of several tens of ps, thereby degrading the CTR. A shorter scintillator can improve CTR; however, this can degrade detection efficiency. Approach. To overcome this trade-off between the CTR and detection efficiency, we previously proposed xDetector, an orthogonally stacked configuration along the longitudinal axis of scintillator crystals. We investigated the CTR potential of the xDetector by improving the scintillator, photodetector, and readout electronics, and by applying CTR correction based on a three-dimensional interaction within the scintillator. Main results. Based on error propagation, the CTR of the paired xDetector was calculated as 113.5 $\pm$ 2.7 ps FWHM. Furthermore, the CTR of the xDetector was measured at four positions along the longitudinal axis by manually sliding the xDetector, and the corrected achieved CTR was 108.6 $\pm$ 1.9 ps FWHM. Moreover, compared with the conventional single detector using a 20.0 mm scintillator, CTR improved by an average of 10.3%. Significance. The xDetector offers potential as a PET detector concept to achieve a CTR of 100 ps FWHM. Such timing performance is expected to improve TOF-PET image quality and quantitative accuracy, contributing to more reliable disease detection and diagnosis than current PET detectors.

physics.med-ph

Multi-Kernel TOF-PET Image Reconstruction Using ADMM

Time-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing attention. However, to fully exploit the latent potential of multi-kernel TOF-PET, new iterative image reconstruction methods are required. In this study, assuming that the events are labeled with the appropriate kernels, we propose an alternating direction method of multipliers (ADMM) for multi-kernel TOF-PET reconstruction, termed TOF-decomp ADMM. As the convergence speed of the TOF-PET log-likelihood depends on the CTR, the proposed method splits the fast- and slow-CTR log-likelihood terms and optimizes them separately under a constraint. This strategy explicitly balances the contributions of fast- and slow-CTR components and enables early stopping at iterations that yield improved contrast-noise trade-offs compared with conventional methods. We validated the proposed method using brain and image quality phantom simulations, demonstrating improved contrast-noise characteristics from a more stabilized convergence. By addressing the convergence imbalance inherent to multi-kernel TOF-PET, this work establishes a framework for exploiting the timing information available in emerging detector technologies.

physics.med-ph

Machine learning enables experimental access to photon-by-photon arrival times in scintillation detectors

Scintillation detectors with excellent timing resolution enable more precise localization of radiation sources in positron emission tomography, leading to substantial improvements in diagnostic capability for diseases such as cancer and dementia. At the extreme timing precision required for such applications at the picosecond scale, detector performance is governed by the microscopic dynamics of scintillation photons generated within the detector and their subsequent detection processes. However, detector signals have conventionally been treated only as collective responses of many photons due to structural constraints inherent to photodetectors. In this study, we overcome this fundamental limitation using deep learning, enabling direct access to the timing information of individual photons. The proposed method estimates photon-by-photon arrival times directly from detector waveforms without requiring any modification to the detector structure; the method operates on an event-by-event basis without ground-truth labels by integrating an unsupervised learning framework with a physically informed detector-response model. Through comprehensive validation combining Monte Carlo simulation and experimental measurements across various detector configurations, we experimentally demonstrate improved timing resolution, visualized depth-of-interaction-dependent photon transport, and classified Cherenkov and scintillation photons based on the estimated photon-level timing information using a unified deep learning-based framework. These results provide experimental access to photon dynamics, bridging the gap between theoretical modeling and experimental observation, and they open a new data-driven pathway for discovery in detector physics and optimization.

physics.ins-det

Scintillator-integrated microchannel plate photomultiplier tubes for ultrafast timing over keV-GeV energy scales

Precise measurement of radiation has long played a vital role in a wide range of research and industrial fields, from fundamental physics beyond the Standard Model to medical imaging such as time-of-flight positron emission tomography. Developing radiation detectors that achieve high timing precision-on the order of a few tens of picoseconds-and energy measurement capabilities remains indispensable yet challenging. In this study, we developed two types of scintillator-integrated microchannel plate photomultiplier tubes (SCI-IMPs), one incorporating barium fluoride, and the other bismuth germanate, to enable simultaneous high-precision timing and energy measurements. To evaluate their performance over a wide energy range from keV- to GeV-scale, electron-positron annihilation gamma rays and cosmic ray muons were used. For energy measurements, both detectors achieved an energy resolution of approximately 35% at 511 keV. For timing measurements using 511 keV, coincidence time resolutions (CTRs) of approximately 50 ps full width at half maximum (FWHM) were obtained for both detectors. In contrast, for cosmic ray muon experiments where cosmic ray muon energy is typically on the order of GeV, CTRs were measured to be 25.1 and 16.8 ps FWHM for barium fluoride- and bismuth germanate-based detectors, respectively. The versatile scintillator-integration technique established in this study can broaden the applicability of the newly developed SCI-IMPs. In particular, these results demonstrate that the developed detectors push the boundaries of timing performance while retaining energy measurement and hold promise for future applications in fundamental physics experiments and medical imaging.

physics.ins-det

Imaging simulation of a dual-panel PET geometry with ultrafast TOF detectors

In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution, demonstrating cross-sectional imaging without reconstruction. Such ultrafast TOF detectors would free PET from conventional ring geometries. Therefore, this study aimed at investigating imaging characteristics of a dual-panel PET with ultrafast TOF detectors using Geant4 simulation. Two detector panels ($137 \times 137~\text{mm}^2$), which consisted of 5.0 mm-thick bismuth germanate pixelized crystals with a 5.75 mm pitch, were placed face-to-face at a 300 mm distance. Imaging characteristics with various TOF resolutions from 30 to 90 ps were evaluated. Because degraded efficiency may cancel TOF gain in image quality, detection efficiency was also parameterized by reducing coincidence counts. Data acquisitions for a numerical multi-rod and uniform phantom (21 MBq) and a modified NEMA NU2 image quality phantom were simulated for 600 s. Results of the maximum likelihood expectation maximization (MLEM) reconstruction were compared with those of a backprojection (i.e., no reconstruction). The dual-panel PET required a 40 ps TOF resolution to have a similar spatial resolution to that of a non-TOF ring PET (300 mm in diameter) for the same detection efficiency. TOF showed benefit in the reconstruction of image quality phantom with 40% efficiency, and the image noise with 20% efficiency at 30 ps TOF was similar to the complete efficiency at 40 ps TOF. MLEM provided better imaging performance than backprojection, even at 30 ps TOF. The feasibility of the proposed dual-panel PET was shown.

physics.med-ph

Instantaneous Core Loss -- Cycle-by-cycle Modeling of Power Magnetics in PWM DC-AC Converters

Nowadays, PWM excitation is one of the most common waveforms seen by magnetic components in power electronic converters. Core loss modelling approaches such as improved Generalized Steinmetz equation (iGSE) or the loss map based on composite waveform hypothesis (CWH) process the PWM excitation piecewisely, which is proven to be effective for DC DC converters. As the additional challenge in PWM DC AC converters, the fundamental-frequency sinewave component induces the "major loop loss" on top of the piecewise high-frequency segments, which however cannot be modelled on a switching cycle basis by any existing methods. To address this gap, this paper proposes a novel fundamental concept, instantaneous core loss, which is the time-domain core loss observed experimentally for the first time in history. Extending the reactive voltage cancellation concept, this work presents a method to measure the instantaneous core loss, which only contains real power loss, as a function of time. Based on measurements in evaluated soft magnetic components, it was discovered that the discharging stage exhibits higher core loss than the charging stage. A modelling approach is then proposed to break down the major loop core loss, typically an average value in the literature, into the time domain to enable cycle-by-cycle modelling of core losses in PWM converters. This work enhances the fundamental understanding of the core loss process by moving from the average model to the time-domain model.

eess.SY

Alleviating the trade-off between coincidence time resolution and sensitivity using scalable TOF-DOI detectors

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging due to the need for sufficiently thick scintillators-typically 20 mm-to ensure adequate sensitivity because the photon transit time spread within these thick scintillators impedes achieving 100 ps CTR. Therefore, thinner scintillators are preferable for CTR better than 100 ps. To address the trade-off between TOF capability and sensitivity, we propose a readout scheme of PET detectors. The proposed scheme utilizes two orthogonally stacked one-dimensional PET detectors, enabling the thickness of the scintillators to be reduced to approximately 13 mm without compromising sensitivity. This is achieved by stacking the detectors along the depth-of-interaction (DOI) axis of a PET scanner. We refer to this design as the cross-stacked detector, or xDetector. Furthermore, the xDetector inherently provides DOI information using the same readout scheme. Experimental evaluations demonstrated that the xDetector achieved a CTR of 175 ps FWHM and an energy resolution of 11% FWHM at 511 keV with 3 x 3 x 12.8 mm3 lutetium oxyorthosilicate crystals, each coupled one-to-one with silicon photomultipliers. In terms of xy-spatial resolution, the xDetector exhibited an asymmetric resolution due to its readout scheme: one resolution was defined by the 3.2 mm readout pitch, while the other was calculated using the center-of-gravity method. The xDetector effectively resolves the trade-off between TOF capability and sensitivity while offering scalability and DOI capability. By integrating state-of-the-art scintillators, photodetectors, and readout electronics with the xDetector scheme, achieving a CTR of 100 ps FWHM alongside high DOI resolution becomes a practical possibility.

physics.ins-det

Concordance of Morse functions on manifolds

In this paper, the concordance of Morse functions is defined, and a necessary and sufficient condition for given two Morse functions to be concordant is presented and is compared with the cobordism criterion. Cobordism of Morse functions on smooth closed manifolds is an equivalence relation defined by using cobordisms of manifolds and fold maps. Given two Morse functions, it is important to decide whether they are cobordant or not, and this problem was first solved for surfaces and then for manifolds of general dimensions by Ikegami-Saeki, Kalm\'ar, and Ikegami. On the other hand, for Morse functions on the same manifold, we can consider a stronger equivalence relation called concordance.

math.GT

Emphasizing Cherenkov photons from bismuth germanate by single photon deconvolution

Bismuth germanate (BGO) has been receiving attention again because it is a potential scintillator for future time-of-flight positron emission tomography. Owing to its optical properties, BGO emits a relatively large number of Cherenkov photons after 511 keV gamma-ray interactions, which pushes the timing resolution of a detector. Nonetheless, efficiently detecting Cherenkov photons among scintillation photons is similar to looking for a needle in a haystack. Thus, we propose a method that can efficiently emphasize Cherenkov photon from a detector waveform by deconvolving a single photon response of photodetector. As a proof-of-concept, we perform the deconvolution, and a probability density function (PDF) of bismuth germanate was obtained, which is compared to a conventional time correlated single photon counting method. Furthermore, we investigate if the proposed deconvolution can emphasize a faint Cherenkov photon. Consequently, the PDF obtained by the proposed deconvolution shows a good agreement with that obtained using a conventional method. A coincidence time resolution obtained using the proposed deconvolution is improved by 43% in full width at half maximum, compared to a voltage-based leading edge discriminator. It can be concluded that the proposed deconvolution method can efficiently emphasize Cherenkov photon and improve the timing performance of BGO-based detectors.

physics.med-ph

Explicitly Multi-Modal Benchmarks for Multi-Objective Optimization

In multi-objective optimization, designing good benchmark problems is an important issue for improving solvers. Controlling the global location of Pareto optima in existing benchmark problems has been problematic, and it is even more difficult when the design space is high-dimensional since visualization is extremely challenging. As a benchmarking with explicit local Pareto fronts, we introduce a benchmarking based on basin connectivity (3BC) by using basins of attraction. The 3BC allows for the specification of a multimodal landscape through a kind of topological analysis called the basin graph, effectively generating optimization problems from this graph. Various known indicators measure the performance of a solver in searching global Pareto optima, but using 3BC can make us localize them for each local Pareto front by restricting it to its basin. 3BC's mathematical formulation ensures the accurate representation of the specified optimization landscape, guaranteeing the existence of intended local and global Pareto optima.

math.OC

Anatomical-Guided Attention Enhances Unsupervised PET Image Denoising Performance

Although supervised convolutional neural networks (CNNs) often outperform conventional alternatives for denoising positron emission tomography (PET) images, they require many low- and high-quality reference PET image pairs. Herein, we propose an unsupervised 3D PET image denoising method based on an anatomical information-guided attention mechanism. The proposed magnetic resonance-guided deep decoder (MR-GDD) utilizes the spatial details and semantic features of MR-guidance image more effectively by introducing encoder-decoder and deep decoder subnetworks. Moreover, the specific shapes and patterns of the guidance image do not affect the denoised PET image, because the guidance image is input to the network through an attention gate. In a Monte Carlo simulation of [$^{18}$F]fluoro-2-deoxy-D-glucose (FDG), the proposed method achieved the highest peak signal-to-noise ratio and structural similarity (27.92 $\pm$ 0.44 dB/0.886 $\pm$ 0.007), as compared with Gaussian filtering (26.68 $\pm$ 0.10 dB/0.807 $\pm$ 0.004), image guided filtering (27.40 $\pm$ 0.11 dB/0.849 $\pm$ 0.003), deep image prior (DIP) (24.22 $\pm$ 0.43 dB/0.737 $\pm$ 0.017), and MR-DIP (27.65 $\pm$ 0.42 dB/0.879 $\pm$ 0.007). Furthermore, we experimentally visualized the behavior of the optimization process, which is often unknown in unsupervised CNN-based restoration problems. For preclinical (using [$^{18}$F]FDG and [$^{11}$C]raclopride) and clinical (using [$^{18}$F]florbetapir) studies, the proposed method demonstrates state-of-the-art denoising performance while retaining spatial resolution and quantitative accuracy, despite using a common network architecture for various noisy PET images with 1/10th of the full counts. These results suggest that the proposed MR-GDD can reduce PET scan times and PET tracer doses considerably without impacting patients.

physics.med-ph

Direct positron emission imaging: ultra-fast timing enables reconstruction-free imaging

Positron emission tomography, like many other tomographic imaging modalities, relies on an image reconstruction step to produce cross-sectional images from projection data. Detection and localization of the back-to-back annihilation photons produced by positron-electron annihilation defines the trajectories of these photons, which when combined with tomographic reconstruction algorithms, permits recovery of the distribution of positron-emitting radionuclides. Here we produce cross-sectional images directly from the detected coincident annihilation photons, without using a reconstruction algorithm. Ultra-fast radiation detectors with a resolving time averaging 32 picoseconds measured the difference in arrival time of pairs of annihilation photons, localizing the annihilation site to 4.8 mm. This is sufficient to directly generate an image without reconstruction and without the geometric and sampling constraints that normally present for tomographic imaging systems.

physics.med-ph

Observation of the "$K^-pp$"-like structure in the $d(π^+, K^+)$ reaction at 1.69 GeV/$c$

We have observed a "$K^-pp$"-like structure in the $d(π^+,K^+)$ reaction at 1.69 GeV/$c$. In this reaction $Λ(1405)$ hyperon resonance is expected to be produced as a doorway to form the $K^-pp$ through the $Λ^*p\rightarrow K^-pp$ process. However, most of the produced $Λ(1405)$'s would escape from deuteron without secondary reactions. Therefore, coincidence of high-momentum ($>$ 250~MeV/$c$) proton(s) in large emission angles ($39^\circ<θ_{lab.}<122^\circ$) was requested to enhance the signal-to-background ratio. A broad enhancement in the proton coincidence spectra are observed around the missing-mass of 2.27 GeV/$c^2$, which corresponds to the $K^-pp$ binding energy of 95 $^{+18}_{-17}$ (stat.) $^{+30}_{-21}$ (syst.) MeV and the width of 162 $^{+87}_{-45}$ (stat.) $^{+66}_{-78}$ (syst.) MeV.

nucl-ex

Inclusive spectrum of the $d(π^+, K^+)$ reaction at 1.69 GeV/c

We have measured an inclusive missing-mass spectrum of the $d(π^+, K^+)$ reaction at the pion incident momentum of 1.69 GeV/$c$ at the laboratory scattering angles between 2$^\circ$ and 16$^\circ$ with the missing-mass resolution of 2.7 $\pm$ 0.1 MeV/$c^2$ (FWHM) at the missing mass of 2.27 GeV/$c^{2}$. In this Letter, we first try to understand the spectrum as a simple quasi-free picture based on several known elementary cross sections, considering the neutron/proton Fermi motion in deuteron. While gross spectrum structures are well understood in this picture, we have observed two distinct deviations; one peculiar enhancement at 2.13 GeV/$c^2$ is due to the $ΣN$ cusp, and the other notable feature is a shift of a broad bump structure, mainly originating from hyperon resonance productions of $Λ(1405)$ and $Σ(1385)^{+/0}$, by about 22.4 $\pm$ 0.4 (stat.) $^{+2.7}_{-1.7}$ (syst.) MeV/$c^2$ toward the low-mass side, which is calculated in the kinematics of a proton at rest as the target.

nucl-ex