Searcharxiv⌕ Search

arXiv subjects

Sébastien Bize

Publications and source records attributed to Sébastien Bize.

11 recordsLinked to original sources

Validation of optical pathlength stability in a LISA test-bench demonstrator

The Laser Interferometer Space Antenna (LISA) observatory is a future L3 mission of the European Space Agency (ESA) to detect gravitational waves, set to launch in 2035. The detector constellation will conduct interferometry to picometer stability over an unprecedented arm length of 2.5 million km. In this paper, we present the development and testing results for the Zerodur interferometer (ZIFO), an optical demonstrator built to validate critical technology for the test setup of the interferometric core of LISA. Optical path length stability measurements on the ZIFO demonstrate successful reduction of bench noise to maintain the 10 pm/$\sqrt{\text{Hz}}$ specification across the 1 mHz to 1 Hz frequency band. We also identify and characterize dominant noise sources from phasemeters and correlations of beam tilt into the path length that were observed during the test campaign.

astro-ph.IM↗

First observation and measurement of the ${}^{198}\text{Hg}$ bosonic transition in an optical lattice clock

We report the first observation of the magnetic-field-induced (5d10 6s2)1S0-(5d10 6s6p)3P0 transition in a bosonic isotope of mercury, 198Hg, realized in an optical lattice clock. We characterize this new isotope, determining key features such as the quadratic Zeeman shift, the probe light shift, and the magic frequency. We also report a first comparison between the 198Hg optical lattice clock and 87Sr. In this comparison, the 198Hg clock has a relative frequency stability of 6x10-16/sqrt(tau/s) and a total relative systematic uncertainty of 6.9x10-16. This comparison yields the first direct determination of the 198Hg/87Sr optical frequency ratio: 198Hg/87Sr = 2.629 315 734 684 118 1, with the same relative uncertainty.

physics.atom-ph↗

Determination of a high spatial resolution geopotential model using atomic clock comparisons

Recent technological advances in optical atomic clocks are opening new perspectives for the direct determination of geopotential differences between any two points at a centimeter-level accuracy in geoid height. However, so far detailed quantitative estimates of the possible improvement in geoid determination when adding such clock measurements to existing data are lacking. We present a first step in that direction with the aim and hope of triggering further work and efforts in this emerging field of chronometric geodesy and geophysics. We specifically focus on evaluating the contribution of this new kind of direct measurements in determining the geopotential at high spatial resolution (~ 10 km). We studied two test areas, both located in France and corresponding to a middle (Massif Central) and high (Alps) mountainous terrain. These regions are interesting because the gravitational field strength varies greatly from place to place at high spatial resolution due to the complex topography. Our method consists in first generating a synthetic high resolution geopotential map, then drawing synthetic measurement data (gravimetry and clock data) from it, and finally reconstructing the geopotential map from that data using least squares collocation. The quality of the reconstructed map is then assessed by comparing it to the original one used to generate the data. We show that adding only a few clock data points (less than 1 % of the gravimetry data) reduces the bias significantly and improves the standard deviation by a factor 3. The effect of the data coverage and data quality on the results is investigated, and the trade-off between the measurement noise level and the number of data points is discussed.

physics.geo-ph↗

Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock

Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.

physics.atom-ph↗

Contributing to TAI with a Secondary Representation of the SI Second

We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in the SI system, i.e. against primary frequency standards, down to a fractional uncertainty of $4.4\times 10^{-16}$, and on the establishment of the recommended value for the $^{87}$Rb hyperfine transition by the CIPM. We also report on the process that led to the participation of the FO2-Rb frequency standard to $Circular~T$ and to the elaboration of TAI. This participation enables us to demonstrate absolute frequency measurement directly in terms of the SI second realized by the TAI ensemble with a statistical uncertainty of $1.1\times 10^{-16}$, therefore at the limit allowed by the accuracy of primary frequency standards. This work constitutes a demonstration of how other secondary representations, based on optical transitions, could also be used for TAI, and an investigation of a number of issues relevant to a future redefinition of the SI second.

physics.atom-ph↗

Improved tests of Local Position Invariance using 87Rb and 133Cs fountains

We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.

physics.atom-ph↗

Progress in Atomic Fountains at LNE-SYRTE

We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

physics.atom-ph↗

Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks

We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.

quant-ph↗

An Optical Lattice Clock with Spin-polarized 87Sr Atoms

We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy.

physics.atom-ph↗

Long-distance frequency dissemination with a resolution of 10-17

We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3.10-14 at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1.10-14 at 1 s.

quant-ph↗

Tests of relativity using a microwave resonator

The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $δ- β+ 1/2 = (1.5\pm 4.2) \times 10^{-9}$ and $β- α- 1 = (-3.1\pm 6.9) \times 10^{-7}$ which is equivalent to the best previous result for the former and represents a 30 fold improvement for the latter.

gr-qc↗