SearcharxivSearch

arXiv subjects

S. A. King

Publications and source records attributed to S. A. King.

12 recordsLinked to original sources

Nonlinear calcium King plot constrains new bosons and nuclear properties

Nonlinearities in King plots (KP) of isotope shifts (IS) can reveal the existence of beyond-Standard-Model (BSM) interactions that couple electrons and neutrons. However, it is crucial to distinguish higher-order Standard Model (SM) effects from BSM physics. We measure the IS of the transitions ${{}^{3}P_{0}~\rightarrow~{}^{3}P_{1}}$ in $\mathrm{Ca}^{14+}$ and ${{}^{2}S_{1/2} \rightarrow {}^{2}D_{5/2}}$ in $\mathrm{Ca}^{+}$ with sub-Hz precision as well as the nuclear mass ratios with relative uncertainties below $4\times10^{-11}$ for the five stable, even isotopes of calcium (${}^{40,42,44,46,48}\mathrm{Ca}$). Combined, these measurements yield a calcium KP nonlinearity with a significance of $\sim 900 σ$. Precision calculations show that the nonlinearity cannot be fully accounted for by the expected largest higher-order SM effect, the second-order mass shift, and identify the little-studied nuclear polarization as the only remaining SM contribution that may be large enough to explain it. Despite the observed nonlinearity, we improve existing KP-based constraints on a hypothetical Yukawa interaction for most of the new boson masses between $10~\mathrm{eV/c^2}$ and $10^7~\mathrm{eV/c^2}$.

physics.atom-ph

Scalable, high-fidelity all-electronic control of trapped-ion qubits

The central challenge of quantum computing is implementing high-fidelity quantum gates at scale. However, many existing approaches to qubit control suffer from a scale-performance trade-off, impeding progress towards the creation of useful devices. Here, we present a vision for an electronically controlled trapped-ion quantum computer that alleviates this bottleneck. Our architecture utilizes shared current-carrying traces and local tuning electrodes in a microfabricated chip to perform quantum gates with low noise and crosstalk regardless of device size. To verify our approach, we experimentally demonstrate low-noise site-selective single- and two-qubit gates in a seven-zone ion trap that can control up to 10 qubits. We implement electronic single-qubit gates with 99.99916(7)% fidelity, and demonstrate consistent performance with low crosstalk across the device. We also electronically generate two-qubit maximally entangled states with 99.97(1)% fidelity and long-term stable performance over continuous system operation. These state-of-the-art results validate the path to directly scaling these techniques to large-scale quantum computers based on electronically controlled trapped-ion qubits.

quant-ph

Coherent Control of Trapped Ion Qubits with Localized Electric Fields

We present a new method for coherent control of trapped ion qubits in separate interaction regions of a multi-zone trap by simultaneously applying an electric field and a spin-dependent gradient. Both the phase and amplitude of the effective single-qubit rotation depend on the electric field, which can be localised to each zone. We demonstrate this interaction on a single ion using both laser-based and magnetic field gradients in a surface-electrode ion trap, and measure the localisation of the electric field.

quant-ph

A Single-Ion Trap with Minimized Ion-Environment Interactions

We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d /dt = 24 +30/-24 per second. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion's position of 0.14 +/- 0.14 K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10^-18 level.

physics.atom-ph

An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions

We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of $Q\approx2.3\times 10^5$ at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts which limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron beam ion trap and deceleration beamline supplying highly charged ions (HCI), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole mass filter with HCI, and trapping of Doppler-cooled ${}^9\text{Be}^+$ Coulomb crystals.

physics.atom-ph

Coherent laser spectroscopy of highly charged ions using quantum logic

Precision spectroscopy of atomic systems is an invaluable tool for the advancement of our understanding of fundamental interactions and symmetries. Recently, highly charged ions (HCI) have been proposed for sensitive tests of physics beyond the Standard Model and as candidates for high-accuracy atomic clocks. However, the implementation of these ideas has been hindered by the parts-per-million level spectroscopic accuracies achieved to date. Here, we cool a trapped HCI to the lowest reported temperatures, and introduce coherent laser spectroscopy on HCI with an eight orders of magnitude leap in precision. We probe the forbidden optical transition in $^{40}$Ar$^{13+}$ at 441 nm using quantum-logic spectroscopy and measure both its excited-state lifetime and $g$-factor. Our work ultimately unlocks the potential of HCI, a large, ubiquitous atomic class, for quantum information processing, novel frequency standards, and highly sensitive tests of fundamental physics, such as searching for dark matter candidates or violations of fundamental symmetries.

physics.atom-ph

Direct comparisons of European primary and secondary frequency standards via satellite techniques

We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.

physics.ins-det

Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications

In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryocooler and providing the lowest vibration level reported for such a closed-cycle system with 1 W cooling power for a <5 K experiment. A decoupling system suppresses vibrations from the cryocooler by three orders of magnitude down to a level of 10 nm peak amplitudes in the horizontal plane. Heat loads of about 40 W (at 45 K) and 1 W (at 4 K) are transferred from an experimental chamber, mounted on an optical table, to the cryocooler through a vacuum-insulated massive 120 kg inertial copper pendulum. The 1.4 m long pendulum allows installation of the cryocooler in a separate, acoustically isolated machine room. In the laser laboratory, we measured the residual vibrations using an interferometric setup. The positioning of the 4 K elements is reproduced to better than a few micrometer after a full thermal cycle to room temperature. Extreme high vacuum on the $10^{-15}$ mbar level is achieved. In collaboration with the Max-Planck-Intitut für Kernphysik (MPIK), such a setup is now in operation at the Physikalisch-Technische Bundesanstalt (PTB) for a next-generation optical clock experiment using highly charged ions.

physics.atom-ph

Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks

We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in the probe shift. We experimentally investigate the scheme using the magnetically-induced $^1$S$_0- ^3$P$_0$ transition in $^{88}$Sr, demonstrating automatic suppression of a sizeable \num{2e-13} probe Stark shift to below \num{1e-16} even with very large errors in shift compensation.

physics.atom-ph

Frequency comparison of ${}^{171}$Yb${}^+$ ion optical clocks at PTB and NPL via GPS PPP

We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the ${{}^2S_{1/2}(F=0)-{}^2D_{3/2}(F=2)}$ electric quadrupole transition in ${}^{171}$Yb${}^+$ via an optical femtosecond frequency comb. To profit from long coherent GPS link measurements we extrapolate over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS link. We determined the total statistical uncertainty consisting of the GPS link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference $y(\mathrm{PTB})-y(\mathrm{NPL})$ of $-1.3(1.2)\times 10^{-15}$ for a total measurement time of 67 h. This result is consistent with an agreement of both optical clocks and with recent absolute frequency measurements against caesium fountain clocks.

physics.atom-ph

Frequency ratio of two optical clock transitions in $^{171}$Yb$^+$ and constraints on the time-variation of fundamental constants

Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of $6\times 10^{-16}$. Combining our results with those from other experiments, we report a three-fold improvement in the constraint on the time-variation of the proton-to-electron mass ratio, $\dotμ/μ = 0.2(1.1)\times 10^{-16}$ year$^{-1}$, along with an improved constraint on time-variation of the fine structure constant, $\dotα/α = -0.7(2.1)\times 10^{-17}$ year$^{-1}$.

physics.atom-ph

Modulation transfer spectroscopy in atomic rubidium

We report modulation transfer spectroscopy on the D2 transitions in 85Rb and 87Rb using a simple home-built electro-optic modulator (EOM). We show that both the gradient and amplitude of modulation transfer spectroscopy signals, for the 87Rb F=2 to F'=3 and the 85Rb F=3 to F'=4 transitions, can be significantly enhanced by expanding the beams, improving the signals for laser frequency stabilization. The signal gradient for these transitions is increased by a factor of 3 and the peak to peak amplitude was increased by a factor of 2. The modulation transfer signal for the 85Rb F=2 to F' transitions is also presented to highlight how this technique can generate a single, clear line for laser frequency stabilization even in cases where there are a number of closely spaced hyperfine transitions.

physics.atom-ph