SearcharxivSearch

arXiv subjects

S. Ajimura

Publications and source records attributed to S. Ajimura.

At least 19 recordsLinked to original sources

Evidence for a $\bar{K}NN$ quasi-bound state in the $\gamma d \to K^0\Lambda p$ reaction

The $\gamma d \to K^{0}\Lambda p$ reaction has been studied to search for a $\bar{K}NN$ quasi-bound state using the LEPS2 solenoid spectrometer at SPring-8. A localized enhancement concentrated at low $q$ is observed in the $(M_{\Lambda p},q)$ distribution below the $K^-pp$ mass threshold, where $M_{\Lambda p}$ is the $\Lambda p$ invariant mass and $q \equiv |\vec{p}_{\gamma}-\vec{p}_{K^{0}}| = |\vec{p}_{\Lambda p}|$ is the momentum transfer. A two-dimensional $(M_{\Lambda p},q)$ fit demonstrates that the enhancement near the threshold is statistically significant, yielding a local significance of $7.3,\sigma$. The enhancement is characterized by effective shape parameters including the Breit--Wigner mass $M$ and width $\Gamma$, and a Gaussian form-factor momentum scale $Q$: $M = 2.354 \pm 0.011(\mathrm{stat.})^{+0.009}_{-0.005}(\mathrm{syst.})~\mathrm{GeV}/c^{2}$, $\Gamma = 0.055 \pm 0.023(\mathrm{stat.})^{+0.031}_{-0.009}(\mathrm{syst.})~\mathrm{GeV}/c^{2}$, and $Q = 0.350 \pm 0.041(\mathrm{stat.})^{+0.035}_{-0.010}(\mathrm{syst.})~\mathrm{GeV}/c$. The obtained results support the existence of a $\bar{K}NN$ quasi-bound state in photoproduction.

nucl-ex

First results from the search for an excess of $\bar{\nu}_{e}$ events in JSNS$^2$

The JSNS$^2$ (J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source) experiment at the Material and Life Science Facility (MLF) of J-PARC is designed to directly test an excess on $\bar{\nu}_{e}$ events which was indicated by LSND (Liquid Scintillator Neutrino Detector). The combination of a short-pulsed proton beam and a gadolinium-loaded liquid scintillator provides an excellent signal-to-noise ratio. In this article, we report the first results of a direct test based on data collected in 2022. After applying all event selection criteria, two events are observed, consistent with the expected background of 2.3$\pm$0.4 events. No excess of $\bar{\nu}_e$ events are seen in this report, however the expected number of events due to LSND anomaly is 1.1$\pm$0.5, thus this result is not yet conclusive. Data taking has been ongoing since 2021 and will continue in future runs. In addition, a new far detector has recently been constructed for the second phase experiment, JSNS$^2$-II, marking an important milestone toward forthcoming measurements.

hep-ex

Prospects for Pentaquark Baryon Search with the Upgraded LEPS2 Facility

We present prospects for the $\Theta^+$ pentaquark baryon search using the newly constructed LEPS2 facility at SPring-8. The LEPS2 detector system features significant improvements in acceptance for multi-particle final states compared to previous experiments. Our search employs two complementary strategies: direct production in the $\gamma n \to K^-\Theta^+$ reaction using a liquid deuterium target with a photon beam up to 2.4 GeV, and $\bar{K}^{*0}$-associated $\Theta^+$ production using a liquid hydrogen target with a photon beam up to 2.9 GeV. The extended acceptance covers both forward and large angle regions, effectively spanning the kinematic regions explored by previous LEPS and CLAS experiments. The large acceptance and improved resolution of LEPS2, combined with these complementary approaches, provide unprecedented sensitivity for establishing the existence of the $\Theta^+$ or placing definitive upper limits on its production.

hep-ex

First Measurement of Missing Energy Due to Nuclear Effects in Monoenergetic Neutrino Charged Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from $K^+ \rightarrow \mu^+ \nu_\mu$ decay at rest ($E_{\nu_\mu}=235.5$ MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly $\nu_\mu n \rightarrow \mu^- p$ or $\nu_\mu$$^{12}\mathrm{C}$ $\rightarrow \mu^-$$^{12}\mathrm{N}$, we define the missing energy as the energy transferred to the nucleus ($\omega$) minus the kinetic energy of the outgoing proton(s), $E_{m} \equiv\omega-\sum T_p$, and relate this to visible energy in the detector, $E_{m}=E_{\nu_\mu} (235.5 \mathrm{MeV})-m_\mu (105.7 \mathrm{MeV}) + [m_n-m_p (1.3 \mathrm{MeV})] - E_{\mathrm{vis}}$. The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g. nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a $(77\pm3)$% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements,and Type-II supernova studies.

hep-ex

Measurement of the mesonic decay branch of the $\bar{K}\!N\!N$ quasi-bound state

We conducted measurements of $K^- + {^3{\rm He}} \to \pi \!Y \!N + N'$ reactions using a $1~{\rm GeV}/c$ $K^-$-beam, with the objective of understanding the broad decay width of $\bar{K} \!N \!N$ (approximately twice as broad as that of $\Lambda(1405)$ considered to be the $\bar{K} \!N$ quasi-bound state). We successfully reproduced distributions of the $\pi \! Y \! N$ invariant mass and momentum transfer for $\pi \! Y \! N$ using model fitting functions for $\bar{K} \!N \!N$ formation and quasi-free $\bar{K}$ absorption (${\rm QF}_{\bar{K}-{\rm abs}}$) processes. The model can describe the experimental data quite well, and four $\bar{K} \! N \! N \to \pi \! Y \! N $ cross-sections were obtained. The results indicate that mesonic decay is the dominant decay branch of $\bar{K} \! N \! N$. The results also suggest that $\Gamma_{\pi \Lambda N} \sim \Gamma_{\pi \Sigma N}$, which indicates that the $I_{\bar{K} \! N}=1$ absorption channel, in addition to the $I_{\bar{K} \! N}=0$ absorption channel, substantially contribute to the $\bar{K} \! N \! N$ decay, making the $\bar{K} \! N \! N$ state approximately twice as unstable as $\Lambda$(1405).

nucl-ex

The acrylic vessel for JSNS$^{2}$-II neutrino target

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS$^{2}$-II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. The specifications, design, and measured properties of the acrylic vessel are described.

hep-ex

Study on the accidental background of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment which searches for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \to \bar{\nu}_{e}$ appearance oscillations using muon decay-at-rest neutrinos. The data taking of JSNS$^2$ have been performed from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29$\pm 0.39) \times 10^{-8}$ / spill with 0.75 MW beam power and comparable to the number of searching signals.

hep-ex

Pole position of $\Lambda(1405)$ measured in $d(K^-,n)\pi\Sigma$ reactions

We measured a set of $\pi^\pm\Sigma^\mp$, $\pi^0\Sigma^0$, and $\pi^-\Sigma^0$ invariant mass spectra below and above the $\bar{K}N$ mass threshold in $K^-$-induced reactions on deuteron. We deduced the $S$-wave $\bar{K}N\rightarrow\pi\Sigma$ and $\bar{K}N\rightarrow\bar{K}N$ scattering amplitudes in the isospin 0 channel in the framework of a $\bar{K}N$ and $\pi\Sigma$ coupled channel. We find that a resonance pole corresponding to $\Lambda(1405)$ is located at 1417.7$^{+6.0}_{-7.4}$(fitting errors)$^{+1.1}_{-1.0}$(systematic errors) + $[-26.1^{+6.0}_{-7.9}$(fitting errors)$^{+1.7}_{-2.0}$(systematic errors)]$i$ MeV/$c^2$, closer to the $\bar{K}N$ mass threshold than the value determined by the Particle Data Group.

nucl-ex

SPring-8 LEPS2 beamline: A facility to produce a multi-GeV photon beam via laser Compton scattering

We have constructed a new laser-Compton-scattering facility, called the LEPS2 beamline, at the 8-GeV electron storage ring, SPring-8. This facility provides a linearly polarized photon beam in a tagged energy range of 1.3--2.4 GeV. Thanks to a small divergence of the low-emittance storage-ring electrons, the tagged photon beam has a size (sigma) suppressed to about 4 mm even after it travels about 130 m to the experimental building that is independent of the storage ring building and contains large detector systems. This beamline is designed to achieve a photon beam intensity higher than that of the first laser-Compton-scattering beamline at SPring-8 by adopting the simultaneous injection of up to four high-power laser beams and increasing a transmittance for the long photon-beam path up to about 77%. The new beamline is under operation for hadron photoproduction experiments.

physics.acc-ph

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \to \bar{\nu}_{e}$ appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the $\bar{\nu}_{e}$ signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS$^2$ experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

hep-ex

Recent results and future prospects of kaonic nuclei at J-PARC

$\bar K$-nuclear bound systems, kaonic nuclei, have been widely discussed as products of the strongly attractive $\bar K N$ interaction in $I = 0$ channels. Recently, we demonstrated that kaonic nuclei can be produced via in-flight $(K^-,N)$ reactions using the low-momentum DC kaon beam at the J-PARC E15 experiment. We observed the simplest kaonic nuclei, $K^-pp$, having a much deeper binding energy than normal nuclei. For further studies, we have proposed a series of experimental programs for the systematic investigation of light kaonic nuclei, from $\bar K N$ ($\Lambda(1405)$) to $\bar K NNNN$. In the new experiment approved as J-PARC E80, we will measure the $\bar K NNN$ ($A=3$) system as a first step toward a comprehensive study.

nucl-ex

The JSNS^2 Detector

The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.

physics.ins-det

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $\Delta m^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $\Delta m^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex

A study on energy resolution of CANDLES detector

In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0\nu\beta\beta$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($\sigma_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $\sigma_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $\sigma_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $\sigma_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($\gamma$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($\gamma$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0\nu\beta\beta$ half-life of $^{48}$Ca can be improved by 1.09 times.

physics.ins-det

Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca

We developed a CANDLES-III system to study the neutrino-less double beta (0$\nu\beta\beta$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$\pi$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $\gamma$-rays caused by the (n, $\gamma$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$\nu\beta\beta$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$\nu\beta\beta$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$\nu\beta\beta$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.

hep-ex

Observation of a $\bar{K}NN$ bound state in the $^3{\rm He} (K^-, \Lambda p)n$ reaction

We have performed an exclusive measurement of the $K^{-}+\! ~^{3}{\rm He} \to \Lambda pn$ reaction at an incident kaon momentum of $1\ {\rm GeV}/c$.In the $\Lambda p$ invariant mass spectrum, a clear peak was observed below the mass threshold of $\bar{K}\!+\!N\!+\!N$, as a signal of the kaonic nuclear bound state, $\bar{K}NN$.The binding energy, decay width, and $S$-wave Gaussian reaction form-factor of this state were observed to be $B_{K} = 42\pm3({\rm stat.})^{+3}_{-4}({\rm syst.})\ {\rm MeV}$, $\Gamma_{K} = 100\pm7({\rm stat.})^{+19}_{-9}({\rm syst.})\ {\rm MeV}$, and $Q_{K} = 383\pm11({\rm stat.})^{+4}_{-1}({\rm syst.})\ {\rm MeV}/c$, respectively. The total production cross-section of $\bar{K}NN$, determined by its $\Lambda p$ decay mode, was $\sigma^{tot}_{K} \cdot BR_{\Lambda p} = 9.3\pm0.8({\rm stat.})^{+1.4}_{-1.0}({\rm syst.})\ \mu{\rm b}$.We estimated the branching ratio of the $\bar{K}NN$ state to the $\Lambda p$ and $\Sigma^{0}p$ decay modes as $BR_{\Lambda p}/BR_{\Sigma^{0}p} \sim 1.7$, by assuming that the physical processes leading to the $\Sigma N\!N$ final states are analogous to those of $\Lambda pn$.

nucl-ex

The JSNS$^{2}$ data acquisition system

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate $\gamma$-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with the flash analog-to-digital converters. We present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

physics.ins-det

Slow control and monitoring system at the JSNS$^{2}$

The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage (HV) of the photomultiplier tubes (PMTs), the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in June 2020. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

physics.ins-det