SearcharxivSearch

arXiv subjects

S. Arai

Publications and source records attributed to S. Arai.

6 recordsLinked to original sources

Gamma-Ray and AntiMatter Survey(GRAMS) experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation experiment using a Liquid Argon Time Projection Chamber (LArTPC) detector to measure MeV gamma rays and antiparticles. MeV gamma-ray observations are important for understanding multi-messenger and time-domain astronomy, enabling exploration of the universe's most potent events, such as supernovae and neutron star mergers. Despite the significance of MeV gamma-rays, GRAMS could also explore the so-called 'MeV gap' region to improve MeV gamma-ray measurement sensitivity that was restricted by the challenge of accurately reconstructing Compton events. Aside from gamma-ray detection, the GRAMS proposed method also serves as an antiparticle spectrometer, targeting the low-energy range of cosmic antinuclei measurements. This work will provide updates on the current status and progress towards the prototype balloon flight with a small-scale LArTPC (pGRAMS) scheduled for early 2026, as well as the recent progress on antihelium-3 sensitivity calculation.

hep-ex

Status of the International Linear Collider

This paper is not a proposal for a CERN future project but provides information on the International Linear Collider (ILC) considered for Japan in order to facilitate the European Strategy discussion in a global context. It describes progress to date, ongoing engineering studies, updated cost estimate for the machine at $\sqrt{s}=250~\rm GeV$ and the situation in Japan. The physics of the ILC is not presented here, but jointly for all Linear Collider projects in a separate document ``A Linear Collider Vision for the Future of Particle Physics'' submitted for the forthcoming European Strategy deliberations.

hep-ex

Antihelium-3 Sensitivity for the GRAMS Experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days $ \times $ 3 flights) and future satellite mission (2-year observation / 10-year observation), the sensitivities become 1.47 $\times$ 10$^{-7}$ [m$^2$ s sr GeV/n]$^{-1}$ and 1.55 $\times$ 10$^{-9}$ [m$^2$ s sr GeV/n]$^{-1}$ / $3.10\times10^{-10}$ [m$^2$ s sr GeV/n]$^{-1}$, respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

hep-ex

First operation of LArTPC in the stratosphere as an engineering GRAMS balloon flight (eGRAMS)

GRAMS (Gamma-Ray and AntiMatter Survey) is a next-generation balloon/satellite experiment utilizing a LArTPC (Liquid Argon Time Projection Chamber), to simultaneously target astrophysical observations of cosmic MeV gamma-rays and conduct an indirect dark matter search using antimatter. While LArTPCs are widely used in particle physics experiments, they have never been operated at balloon altitudes. An engineering balloon flight with a small-scale LArTPC (eGRAMS) was conducted on July 27th, 2023, to establish a system for safely operating a LArTPC at balloon altitudes and to obtain cosmic-ray data from the LArTPC. The flight was launched from the Japan Aerospace Exploration Agency's (JAXA) Taiki Aerospace Research Field in Hokkaido, Japan. The total flight duration was 3 hours and 12 minutes, including a level flight of 44 minutes at a maximum altitude of 28.9 km. The flight system was landed on the sea and successfully recovered. The LArTPC was successfully operated throughout the flight, and about 0.5 million events of the cosmic-ray data including muons, protons, and Compton scattering gamma-ray candidates, were collected. This pioneering flight demonstrates the feasibility of operating a LArTPC in high-altitude environments, paving the way for future GRAMS missions and advancing our capabilities in MeV gamma-ray astronomy and dark matter research.

astro-ph.IM

Cosmic Ray Tests of the Prototype TPC for the ILC Experiment

A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments under a magnetic field up to 4 T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC readout could not be a fall-back option of the ILC-TPC under a strong axial magnetic field of 4 T since its spatial resolution suffered severely from the so called E x B effect in the vicinity of the wire planes. The GEM readout, on the other hand, was found to be virtually free from the E x B effect as had been expected and gave the resolution determined by the transverse diffusion of the drift electrons (diffusion limited). Furthermore, GEMs allow a wider choice of gas mixtures than MWPCs. Among the gases we tried so far a mixture of Ar-CF4-isobutane, in which MWPCs could be prone to discharges, seems promising as the operating gas of the ILC-TPC because of its small diffusion constant especially under a strong magnetic field. We report the measured drift properties of this mixture including the diffusion constant as a function of the electric field and compare them with the predictions of Magboltz. Also presented is the spatial resolution of a GEM-based ILC-TPC estimated from the measurement with the prototype.

physics.ins-det

Re-appearance of antiferromagnetic ordering with Zn and Ni substitution in La_{2-x}Sr_xCuO_4

The effects of nonmagnetic Zn and magnetic Ni substitution for Cu site on magnetism are studied by measurements of uniform magnetic susceptibility for lightly doped La_{2-x}Sr_xCu_{1-z}M_zO_4 (M=Zn or Ni) polycrystalline samples. For the parent x=0, Zn doping suppresses the Néel temperature T_N whereas Ni doping hardly changes T_N up to z=0.3. For the lightly doped samples with T_N~0, the Ni doping recovers T_N. For the superconducting samples, the Ni doping induces the superconductivity-to-antiferromagnetic transition (or crossover). All the heavily Ni doped samples indicate a spin glass behavior at \~15 K.

cond-mat.supr-con