SearcharxivSearch

arXiv subjects

S. Argirò

Publications and source records attributed to S. Argirò.

12 recordsLinked to original sources

Toward High-Resolution Detection of Target Fragmentation: TEA-Sensitized NIT for Proton Therapy Applications

Nano Imaging Trackers (NIT) are fine-grained nuclear emulsions capable of tracking charged particles with sub-micrometric spatial resolution. The DAMON (Direct Measurement of Target Fragmentation) experiment recently employed NIT to detect target-fragmentation events relevant to proton therapy in direct kinematics. These measurements showed that the small crystal size, while providing high spatial resolution, limits the reconstruction efficiency for primary proton tracks and high-energy secondary protons. This work reports an enhancement of NIT sensitivity achieved through alternative chemical sensitization methods, namely gold-plus-sulfur (Au-S) and triethanolamine (TEA), together with the use of the GR-1 developer. The detector response was evaluated with gamma-ray, carbon-ion and proton exposures, including clinically relevant proton energies.

physics.ins-det

Angular differential and elemental fragmentation cross sections of a $400\,\text{MeV/nucleon}$ $^{16}\text{O}$ beam on a graphite target with the FOOT experiment

This paper presents the measurements of the angular differential cross sections for the forward production of He, Li, Be, B, C and N nuclei in the fragmentation process of a 400$\text{MeV/nucleon}$ $^{16}\text{O}$ beam interacting with a graphite target. Due to the limited data available in this energy regime, these measurements of nuclear fragmentation cross sections are relevant to improve nuclear interaction models for Particle Therapy and space radioprotection applications. The data analyzed in this paper were collected during a measurement campaign carried out at the GSI Helmholtz Center for Heavy Ion Research facility in Darmstadt (Germany) by the FOOT collaboration. The results are compared with similar results found in the literature and with a previous FOOT measurement of the same process, using the same setup, from a previous pilot run performed at GSI. The pilot run data, however, had limited statistics and only allowed for the measurement of elemental fragmentation cross sections integrated in the setup acceptance. This data set, with statistics more than 100 times larger compared to the data collected in the previous run, enabled the measurement of angular differential cross sections, fully exploiting the granularity of the FOOT $Δ\text{E}$-TOF system. Furthermore, a better comprehension of the FOOT apparatus allowed to improve the analysis techniques, leading to a reduction in the final systematic uncertainties.

nucl-ex

Cross Section Measurements of Large Angle Fragments Production in the Interaction of Carbon Ion Beams with Thin Targets

The fragmentation cross sections of carbon ion beams with kinetic energies of $115 - 353~\text{MeV/u}$ impinging on thin targets of graphite (C), polyvinyl-toluene (C$_9$H$_{10}$) and PMMA (C$_2$O$_5$H$_8$) have been measured at 90$^{\text{o}}$ and 60$^{\text{o}}$ at the CNAO particle therapy center (Pavia, Italy). The presented measurements are a complete reanalysis by the FOOT collaboration of already published elemental cross section on composite targets, in order to refine the analysis, improve the systematic uncertainties and show the comparison with the FLUKA Monte Carlo code calculations. In this work, the kinetic energy at production of measured fragments has been completely redefined, together with the efficiencies computation. The new analysis strategy has been successfully validated against the Monte Carlo cross sections. Two detection arms were positioned at two different angles to perform the measurement at 90$^{\text{o}}$ and 60$^{\text{o}}$. The fragment species have been identified in charge (Z$_{id}$ = H) and mass (M$_{id}$ = $^1$H, $^2$H, $^3$H) combining the information of the deposited energy in thin plastic scintillators, of the deposited energy in a thick LYSO crystal and of the fragments Time of Flight (ToF) measurement. The ToF was also used to compute the fragments measured kinetic energy. The cross sections are presented as a function of the fragments kinetic energy at production thanks to an unfolding technique applied to the data.

nucl-ex

Comparison of Fast Amplifiers for Diamond Detectors

The development of Chemical Vapour Deposition (CVD) diamond detectors requests for novel signal amplifiers, capable to match the superb signal-to-noise ratio and timing response of these detectors. Existing amplifiers are still far away from this goal and are the dominant contributors to the overall system noise and the main source of degradation of the energy and timing resolution. We tested a number of commercial amplifiers designed for diamond detector readout to identify the best solution for a particular application. This application required a deposited energy threshold below 100 keV and timing resolution of the order of 200 ps at 200 keV. None of tested amplifiers satisfies these requirements. The best solution to such application found to be the Cividec C6 amplifier, which allows 100 keV minimal threshold, but its coincidence timing resolution at 200 keV is as large as 1.2 ns.

physics.ins-det

Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory

The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above $3\times 10^{18}$ eV, for all zenith angles between 0$^\circ$ and 60$^\circ$, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

astro-ph.IM

The Fluorescence Detector of the Pierre Auger Observatory

The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.

astro-ph.IM

Operations of and Future Plans for the Pierre Auger Observatory

Technical reports on operations and features of the Pierre Auger Observatory, including ongoing and planned enhancements and the status of the future northern hemisphere portion of the Observatory. Contributions to the 31st International Cosmic Ray Conference, Lodz, Poland, July 2009.

astro-ph.IM

CMS Software Distribution on the LCG and OSG Grids

The efficient exploitation of worldwide distributed storage and computing resources available in the grids require a robust, transparent and fast deployment of experiment specific software. The approach followed by the CMS experiment at CERN in order to enable Monte-Carlo simulations, data analysis and software development in an international collaboration is presented. The current status and future improvement plans are described.

cs.DC