SearcharxivSearch

arXiv subjects

S. Bize

Publications and source records attributed to S. Bize.

35 records · Page 2Linked to original sources

Feshbach resonances in Cesium at Ultra-low Static Magnetic Fields

We have observed Feshbach resonances for 133Cs atoms in two different hyperfine states at ultra-low static magnetic fields by using an atomic fountain clock. The extreme sensitivity of our setup allows for high signal-to-noise-ratio observations at densities of only 2*10^7 cm^{-3}. We have reproduced these resonances using coupled-channels calculations which are in excellent agreement with our measurements. We justify that these are s-wave resonances involving weakly-bound states of the triplet molecular Hamiltonian, identify the resonant closed channels, and explain the observed multi-peak structure. We also describe a model which precisely accounts for the collisional processes in the fountain and which explains the asymmetric shape of the observed Feshbach resonances in the regime where the kinetic energy dominates over the coupling strength.

cond-mat.quant-gas

A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty

We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are loaded from a single stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. The frequency of the clock transition is found to be 1 128 575 290 808 162.0 +/-6.4 (sys.) +/-0.3 (stat.) Hz (fractional uncertainty = 5.7x10^(-15)). Neither an atom number nor second order Zeeman dependence have yet to be detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing and detection.

physics.atom-ph

An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock

We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low thermal noise limits associated with this material. By stabilizing the frequency of a 1062.6 nm Yb-doped fiber laser to the cavity, and including an additional link to LNE-SYRTE's fountain primary frequency standards via an optical frequency comb, we produce a signal which is both stable at the 1E-15 level in fractional terms and referenced to primary frequency standards. The signal is subsequently amplified and frequency-doubled twice to produce several milliwatts of interrogation signal at 265.6 nm in the deep ultraviolet.

physics.atom-ph

Ultrastable lasers based on vibration insensitive cavities

We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5e-11 per m.s^-2 for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuning to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6e-16 at 1 second, which is the best result obtained for this length of cavity.

physics.optics

Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock

We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.

physics.atom-ph

Doppler-free spectroscopy of the 1S0-3P0 optical clock transition in laser-cooled fermionic isotopes of neutral mercury

We have performed for the first time direct laser spectroscopy of the 1S0-3P0 optical clock transition at 265.6 nm in fermionic isotopes of neutral mercury laser-cooled in a magneto-optical trap. Spectroscopy is performed by measuring the depletion of the magneto-optical trap induced by the excitation of the long-lived 3P0 state by a probe at 265.6 nm. Measurements resolve the Doppler-free recoil doublet allowing for a determination of the transition frequency to an uncer- tainty well below the Doppler-broadened linewidth. We have performed absolute measurement of the frequency with respect to an ultra-stable reference monitored by LNE-SYRTE fountain pri- mary frequency standards using a femtosecond laser frequency comb. The measured frequency is 1128575290808 +/- 5.6 kHz in 199Hg and 1128569561140 +/- 5.3 kHz in 201Hg, more than 4 orders of magnitude better than previous indirect determinations. Owing to a low sensitivity to blackbody radiation, mercury is a promising candidate for reaching the ultimate performance of optical lattice clocks.

physics.atom-ph

Long Term Operation and Performance of Cryogenic Sapphire Oscillators

Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.

physics.ins-det

First observation of feshbach resonances at very low magnetic field in a 133Cs fountain

One of the main limitations of cesium atomic fountains has been the cold collision frequency shift. By using a method based on a transfer of population by adiabatic passage allowing to prepare cold atomic samples with a well defined ratio of atomic density as well as atom number the collisional shift is controlled at the 10E-3 of its value. A calibration of Zeeman sub-states contribution to the clock shift as a function of the field has been performed. Feshbach resonances have been observed for the first time at very low magnetic field and with a very good resolution. A Monte Carlo simulation has been performed and could fit properly some of experimental data. This constrains some parameters of the theory of collisions.

physics.atom-ph

Interference-filter-stabilized external-cavity diode lasers

We have developed external-cavity diode lasers, where the wavelength selection is assured by a low loss interference filter instead of the common diffraction grating. The filter allows a linear cavity design reducing the sensitivity of the wavelength and the external cavity feedback against misalignment. By separating the feedback and wavelength selection functions, both can be optimized independently leading to an increased tunability of the laser. The design is employed for the generation of laser light at 698, 780 and 852 nm. Its characteristics make it a well suited candidate for space-born lasers.

physics.optics

Cold atom Clocks and Applications

This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of $2\times 10^{-16}$ at $50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of $7\times 10^{-16}$, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using $^{87}$Rb and $^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.

physics.atom-ph

New Limits to the Drift of Fundamental Constants from Laboratory Measurements

We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency in $^{199}$Hg$^+$ against $ν_{\rm {Cs}}$ and a microwave $^{87}$Rb and $^{133}$Cs clock comparison, we deduce separate limits on $\dotα/α= (-0.9\pm 2.9)\times 10^{-15}$ yr$^{-1}$ and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments $μ_{\rm {Rb}}/μ_{\rm {Cs}}$ equal to $(-0.5 \pm 1.7)\times 10^{-15}$ yr$^{-1}$. The latter provides information on the temporal behavior of the constant of strong interaction.

physics.optics

Astrophysical constraints on hypothetical variability of fundamental constants

(Abridged) Many-multiplet (MM) method applied to three inhomogeneous samples of Keck/HIRES quasar absorption spectra gives a shift in the value of the fine-structure constant of Delta alpha/alpha = (-5.4+/-1.2) 10^{-6} in the redshift range 0.2 < z < 3.7 (Murphy et al. 2003).The 1sigma error is, however, much too small and cannot be maintained by current observations of quasars. We present a modified MM method to set an upper limit on Delta alpha/alpha from a homogeneous sample of FeII lines identified in the up-to-date best quality VLT/UVES spectrum of HE 0515-4414. Our result is Delta alpha/alpha = (1.1+/-1.1) 10^{-5} at z = 1.149. Theoretical models of the fundamental physical interactions predict that the proton-to-electron mass ratio (mu = m_p/m_e) may relate to the shift in Delta alpha/alpha as Delta mu/mu = R Delta alpha/alpha. We use VLT/UVES high-resolution observations of molecular hydrogen H2 ultraviolet absorption lines at z = 3.025 toward Q 0347-3818 to bound the value of R. The obtained constraints on Delta ln mu = (2.1+/-3.6) 10^{-5} and on Delta ln alpha = (1.1+/-1.1) 10^{-5} rule out vary large values of |R| > 6.

astro-ph

Tests of Lorentz Invariance Using a Microwave Resonator: An Update

The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $δ- β+ 1/2 \leq 3.4 \times 10^{-9}$ and $β- α- 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.

gr-qc

A Search for Variations of Fundamental Constants using Atomic Fountain Clocks

Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.

physics.atom-ph

Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs) m_e / m_p alpha^6.0 at the same level.

physics.atom-ph

133Cs87Rb Laser Cooled Dual Fountain

At BNM-SYRTE laboratories in Paris two 133Cs fountains and a 87Rb one have been already demonstrated. This paper illustrates the construction of a 87Rb and Cs dual fountain realized within the same structure to work simultaneously. Up to now only the Cs part is under operation but Rb part, already completed, will be soon operational. The experiment has been projected to improve present fountain frequency standards and to perform a more precise laboratory test (at 10E-16 level) on a possible time variation of the fine structure constant alpha, as recent cosmological evidences strongly motivates.

physics.atom-ph

Controlling the cold collision shift in high precision atomic interferometry

We present here a new method based on a transfer of population by adiabatic passage that allows to prepare cold atomic samples with a well defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountains accuracy at the $10^{-16}$ level realistic. With an improved set-up, the adiabatic passage would allow measurements of atom number-dependent phase shifts at the $10^{-3}$ level in high precision experiments.

physics.atom-ph