SearcharxivSearch

arXiv subjects

S. Brambilla

Publications and source records attributed to S. Brambilla.

18 recordsLinked to original sources

AGATA: Advancements in Software Developments

Presently, gamma-ray tracking in germanium segmented detectors is realised by applying two advanced, complex algorithms. While they have already triggered an intensive R&D, they are still subject to further improvements. Making such algorithms effective, online in real time conditions and/or offline for deeper analysis, in data pipelines do require many additional software developments. This review paper gives an overview of the various bricks of software produced so far by the AGATA collaboration. It provides hints of what is foreseen for the next phases of the project up to its full configuration namely with 180 capsules in the array.

physics.ins-det

Optimization and first electronic implementation of the Constant-Fraction Time-Over-Threshold pulse shape discrimination method

In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray pulse shape discrimination (PSD). The superiority of the CF-ToT PSD method over the constant-threshold (CT-ToT) method was previously demonstrated, down to low neutron energy thresholds of 100 keVee. Here, we report on a quantitative comparison between the traditionally used Charge Comparison (CC) method and the CF-ToT method using a stilbene scintillator coupled to a silicon photomultiplier, implementing an offline analysis of recorded fast-neutron and gamma-ray waveforms. An optimization of the constant fraction value indicates that a 20%-fraction yields the optimum figure-of-merit (FOM) and gamma-ray peak-to-valley (P/V) ratio. The results obtained for a particle energy threshold of 100 keVee show that the FOM and P/V values achieved with the CF-ToT method are superior to those obtained using the standard CC method. In addition, a first electronic implementation of the CF-ToT method was performed using simple circuitry suitable for multichannel architecture. Initial results obtained with this circuit prototype are presented.

physics.ins-det

Complete set of bound negative-parity states in the neutron-rich 18N nucleus

High-resolution gamma-ray spectroscopy of 18N is performed with the Advanced GAmma Tracking Array AGATA, following deep-inelastic processes induced by an 18O beam on a 181Ta target. Six states are newly identified, which together with the three known excitations exhaust all negative-parity excited states expected in 18N below the neutron threshold. Spin and parities are proposed for all located states on the basis of decay branchings and comparison with large-scale shell-model calculations performed in the p-sd space, with the YSOX interaction. Of particular interest is the location of the 0^-_1 and 1^-_2 excitations, which provide strong constrains for cross-shell p-sd matrix elements based on realistic interactions, and help to simultaneously reproduce the ground and first-excited states in 16N and 18N, for the first time. Understanding the 18N structure may also have significant impact on neutron-capture cross-section calculations in r-process modeling including light neutron-rich nuclei.

nucl-ex

Accessing tens-to-hundreds femtoseconds nuclear state lifetimes with low-energy binary heavy-ion reactions

A novel Monte Carlo technique has been developed to determine lifetimes of excited states in the tens-to-hundreds femtoseconds range. The method is applied to low-energy heavy-ion binary reactions populating nuclei with complex velocity distributions. Its relevance is demonstrated in connection with the $^{18}$O(7.0 MeV/u) + $^{181}$Ta experiment, performed at GANIL with the AGATA+VAMOS+PARIS setup, to study neutron-rich O, C, N, ... nuclei. Excited states in $^{17}$O and $^{19}$O, with known lifetimes, are used to validate the method over the $\sim$20-400 fs lifetime-sensitivity range. Emphasis is given to the unprecedented position resolution provided by $γ$-tracking arrays, which turns out to be essential for reaching the required accuracy in Doppler-shift correction, at the basis of the detailed analysis of $γ$-ray lineshape and resulting state lifetime determination. The technique is anticipated to be an important tool for lifetime investigations in exotic neutron-rich nuclei, produced with intense ISOL-type beams.

nucl-ex

Testing ab initio nuclear structure in neutron-rich nuclei: lifetime measurements of second 2+ states in 16C and 20O

To test the predictive power of ab initio nuclear structure theory, the lifetime of the second 2+ state in neutron-rich 20O, tau(2+_2 ) = 150(+80-30) fs, and an estimate for the lifetime of the second 2+ state in 16C have been obtained, for the first time. The results were achieved via a novel Monte Carlo technique that allowed us to measure nuclear state lifetimes in the tens-to-hundreds femtoseconds range, by analyzing the Doppler-shifted gamma-transition line shapes of products of low-energy transfer and deep-inelastic processes in the reaction 18O (7.0 MeV/u) + 181Ta. The requested sensitivity could only be reached owing to the excellent performances of the AGATA gamma-tracking array, coupled to the PARIS scintillator array and to the VAMOS++ magnetic spectrometer. The experimental lifetimes agree with predictions of ab initio calculations using two- and three-nucleon interactions, obtained with the valence-space in-medium similarity renormalization group for 20O, and with the no-core shell model for 16C. The present measurement shows the power of electromagnetic observables, determined with high-precision gamma spectroscopy, to assess the quality of first-principles nuclear structure calculations, complementing common benchmarks based on nuclear energies. The proposed experimental approach will be essential for short lifetimes measurements in unexplored regions of the nuclear chart, including r-process nuclei, when intense ISOL-type beams become available.

nucl-ex

Fast Neutron Detection Efficiency of 6Li and 7Li Enriched CLYC Scintillators using an Am-Be source

The fast neutrons produced by a calibrated 241Am-Be source were detected by two different Cs2LiYCl6:Ce (CLYC) scintillator detectors. The two cylindrical crystals (1"x1" in size) were enriched with more than 99% of 7Li (C7LYC) and with about 95% of 6Li (C6LYC), respectively. Both crystals can detect fast neutrons whereas only C6LYC can also detect thermal neutrons, due to the presence of 6Li. The measurement was performed at the L.A.S.A. Laboratory of INFN and University of Milano (Italy). To identify the neutron events, the Pulse-Shape-Discrimination technique was used. A value for the detection efficiency of the 241Am-Be emitted neutrons, with energy up to 10 MeV, was deduced.

physics.ins-det

Testing the capability of low-energy light ions identification of the TRACE silicon detectors

The in-beam tests of two Si pixel type TRACE detectors have been performed at Laboratori Nazionali di Legnaro (Italy). The aim was to investigate the possibility of identifying heavy-ion reactions products with mass A~10 at low kinetic energy, i.e., around 10 MeV. Two separate read-out chains, digital and analog, were used. The Pulse Shape Analysis technique was employed to obtain the identification matrices for the digitally processed part of the data. Separation in both charge and mass was obtained, however, the $α$ particles contaminated significantly the recorded data in the lower energy part. Due to this effect, the identification of the light products ($^{7,6}$Li isotopes) could be possible down only to ~20 MeV

physics.ins-det

Charged particle decay of hot and rotating $^{88}$Mo nuclei in fusion-evaporation reactions

A study of fusion-evaporation and (partly) fusion-fission channels for the $^{88}$Mo compound nucleus, produced at different excitation energies in the reaction $^{48}$Ti + $^{40}$Ca at 300, 450 and 600 MeV beam energies, is presented. Fusion-evaporation and fusion-fission cross sections have been extracted and compared with the existing systematics. Experimental data concerning light charged particles have been compared with the prediction of the statistical model in its implementation in the Gemini++ code, well suited even for high spin systems, in order to tune the main model parameters in a mass region not abundantly covered by exclusive experimental data. Multiplicities for light charged particles emitted in fusion evaporation events are also presented. Some discrepancies with respect to the prediction of the statistical model have been found for forward emitted $α$-particles; they may be due both to pre-equilibrium emission and to reaction channels (such as Deep Inelastic Collisions, QuasiFission/QuasiFusion) different from the compound nucleus formation.

nucl-ex

Nuclear astrophysics with radioactive ions at FAIR

The nucleosynthesis of elements beyond iron is dominated by neutron captures in the s and r processes. However, 32 stable, proton-rich isotopes cannot be formed during those processes, because they are shielded from the s-process flow and r-process beta-decay chains. These nuclei are attributed to the p and rp process. For all those processes, current research in nuclear astrophysics addresses the need for more precise reaction data involving radioactive isotopes. Depending on the particular reaction, direct or inverse kinematics, forward or time-reversed direction are investigated to determine or at least to constrain the desired reaction cross sections. The Facility for Antiproton and Ion Research (FAIR) will offer unique, unprecedented opportunities to investigate many of the important reactions. The high yield of radioactive isotopes, even far away from the valley of stability, allows the investigation of isotopes involved in processes as exotic as the r or rp processes.

astro-ph.IM

Measurement of light charged particles in the decay channels of medium-mass excited compound nuclei

The 48Ti on 40Ca reactions have been studied at 300 and 600 MeV focusing on the fusion-evaporation (FE) and fusion-fission (FF) exit channels. Energy spectra and multiplicities of the emitted light charged particles have been compared to Monte Carlo simulations based on the statistical model. Indeed, in this mass region (A about 100) models predict that shape transitions can occur at high spin values and relatively scarce data exist in the literature about coincidence measurements between evaporation residues and light charged particles. Signals of shape transitions can be found in the variations of the lineshape of high energy gamma rays emitted from the de-excitation of GDR states gated on different region of angular momenta. For this purpose it is important to keep under control the FE and FF processes, to regulate the statistical model parameters and to control the onset of possible preequilibrium emissions from 300 to 600 MeV bombarding energy.

nucl-ex

Characterization of Large Volume 3.5 x 8 inches LaBr3:Ce Detectors

The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever produced and still need to be fully characterized to determine how these detectors can be utilized and in which applications. We tested the detectors using monochromatic gamma-ray sources and in-beam reactions producing gamma rays up to 22.6 MeV; we acquired PMT signal pulses and calculated detector energy resolution and response linearity as a function of gamma-ray energy. Two different voltage dividers were coupled to the Hamamatsu R10233-100SEL PMT: the Hamamatsu E1198-26, based on straightforward resistive network design, and the LABRVD, specifically designed for our large volume LaBr3:Ce scintillation detectors, which also includes active semiconductor devices. Because of the extremely high light yield of LaBr3:Ce crystals we observed that, depending on the choice of PMT, voltage divider and applied voltage, some significant deviation from the ideally proportional response of the detector and some pulse shape deformation appear. In addition, crystal non-homogeneities and PMT gain drifts affect the (measured) energy resolution especially in case of high-energy gamma rays. We also measured the time resolution of detectors with different sizes (from 1x1 inches up to 3.5x8 inches), correlating the results with both the intrinsic properties of PMTs and GEANT simulations of the scintillation light collection process. The detector absolute full energy efficiency was measured and simulated up to gamma-rays of 30 MeV

physics.ins-det

Identification and rejection of scattered neutrons in AGATA

Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold segmented high-purity germanium crystals), placed at a distance of 50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment was to study the interaction of neutrons in the segmented high-purity germanium detectors of AGATA and to investigate the possibility to discriminate neutrons and gamma rays with the gamma-ray tracking technique. The BaF2 detectors were used for a time-of-flight measurement, which gave an independent discrimination of neutrons and gamma rays and which was used to optimise the gamma-ray tracking-based neutron rejection methods. It was found that standard gamma-ray tracking, without any additional neutron rejection features, eliminates effectively most of the interaction points due to recoiling Ge nuclei after elastic scattering of neutrons. Standard tracking rejects also a significant amount of the events due to inelastic scattering of neutrons in the germanium crystals. Further enhancements of the neutron rejection was obtained by setting conditions on the following quantities, which were evaluated for each event by the tracking algorithm: energy of the first and second interaction point, difference in the calculated incoming direction of the gamma ray, figure-of-merit value. The experimental results of tracking with neutron rejection agree rather well with Geant4 simulations.

nucl-ex

AGATA - Advanced Gamma Tracking Array

The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation gamma-ray spectrometer. AGATA is based on the technique of gamma-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a gamma ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realization of gamma-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly-segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterization of the crystals was measured and compared with detector-response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximize its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer.

physics.ins-det

Response of AGATA Segmented HPGe Detectors to Gamma Rays up to 15.1 MeV

The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(11B,ng)12C at Ebeam = 19.1 MeV, while gamma-rays between 2 to 9 MeV were produced using an Am-Be-Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%. Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppression of background radiation following neutron capture by Ge nuclei. Finally the Doppler correction for the 15.1 MeV gamma line, performed using the position information extracted with Pulse-shape Analysis, is discussed.

nucl-ex

Neutron-skin thickness from the study of the anti-analog giant dipole resonance

The gamma-decay of the anti-analog of the giant dipole resonance (AGDR) has been measured to the isobaric analog state excited in the p(124Sn,n) reaction at a beam energy of 600 MeV/nucleon. The energy of the transition was also calculated with state-of-the-art self-consistent random-phase approximation (RPA) and turned out to be very sensitive to the neutron-skin thickness (\DeltaR_(pn)). By comparing the theoretical results with the measured one, the \DeltaR_(pn) value for 124Sn was deduced to be 0.175 \pm 0.048 fm, which agrees well with the previous results. The energy of the AGDR measured previously for ^(208)Pb was also used to determine the \DeltaR_(pn) for ^(208)Pb. In this way a very precise \DeltaR_(pn) = 0.181 \pm 0.031 neutron-skin thickness has been obtained for 208Pb. The present method offers new possibilities for measuring the neutron-skin thicknesses of very exotic isotopes.

nucl-ex

Probing the order-to-chaos region in superdeformed 151Tb and 196Pb nuclei with continuum gamma-transitions

The gamma-decay associated with the warm rotation of the superdeformed (SD) nuclei 151Tb and 196Pb has been measured with the EUROBALL IV array. Several independent quantities provide a stringent test of the population and decay dynamics in the SD well. A Monte Carlo simulation of the gamma-decay based on microscopic calculations gives remarkable agreement with the data only assuming a large enhancement of the B(E1) strength at low excitation energy, which may be related to the evidence for octupole vibrations in both mass regions.

nucl-ex

Evidence for the Jacobi shape transition in hot 46Ti

The gamma-rays from the decay of the GDR in 46Ti compound nucleus formed in the 18O+28Si reaction at bombarding energy 105 MeV have been measured in an experiment using a setup consisting of the combined EUROBALL IV, HECTOR and EUCLIDES arrays. A comparison of the extracted GDR lineshape data with the predictions of the thermal shape fluctuation model shows evidence for the Jacobi shape transition in hot 46Ti. In addition to the previously found broad structure in the GDR lineshape region at 18-27 MeV caused by large deformations, the presence of a low energy component (around 10 MeV), due to the Coriolis splitting in prolate well deformed shape, has been identified for the first time.

nucl-ex

Search for the Jacobi shape transition in light nuclei

The gamma-rays following the reaction 105 MeV 18O + 28Si have been measured using the EUROBALL IV, HECTOR and EUCLIDES arrays in order to investigate the predicted Jacobi shape transition. The high-energy gamma-ray spectrum from the GDR decay indicates a presence of large deformations in hot 46Ti nucleus, in agreement with new theoretical calculations based on the Rotating Liquid Drop model.

nucl-ex