SearcharxivSearch

arXiv subjects

S. Ceravolo

Publications and source records attributed to S. Ceravolo.

9 recordsLinked to original sources

Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter

CRILIN is a high-granularity semi-homogeneous electromagnetic calorimeter based on longitudinally segmented PbF$_2$ crystal matrices read out by UV-extended silicon photomultipliers. The concept combines fast Cherenkov response, fine transverse granularity, longitudinal shower information, and radiation tolerance for future lepton-collider experiments. This paper reports the construction of a large-area prototype and its performance measured in beam tests at the CERN SPS. The detector comprises five $7\times7$ PbF$_2$ crystal matrices, has a depth of about $22X_0$, and is read out by four $3\times3~\mathrm{mm}^2$ SiPMs per crystal integrated in a single electronic channel. Electron data between 10 and 120~GeV and dedicated 150~GeV muon data were used to characterize the detector response. A time resolution below 50~ps is achieved for electron energies above 10~GeV, reaching values below 20~ps above 60~GeV. The energy resolution is described by a stochastic term of $(6.58\pm0.04)\%/\sqrt{E/\mathrm{GeV}}$ and a constant term of $(0.23\pm0.02)\%$, with an additional noise contribution fixed from pedestal data. The longitudinal segmentation enables event-by-event corrections based on the reconstructed shower development, resulting in a significant improvement of the energy resolution. A light yield of approximately 0.54~photoelectrons/MeV is measured consistently using both electron showers and minimum-ionizing particles. A Geant4-based simulation incorporating the relevant experimental effects reproduces the measured energy resolution. These results validate the CRILIN architecture as a compact, fast, and longitudinally segmented electromagnetic calorimeter for future collider experiments.

physics.ins-det

Interim report for the International Muon Collider Collaboration (IMCC)

The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.

physics.acc-ph

Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation

Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small ($10\times10\times40$~mm$^3$) lead fluoride (PbF$_2$) and ultra-fast lead tungstate (PbWO$_4$, PWO) crystals with 120~GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout scheme. For a single crystal of PbF$_2$, corresponding to a single Crilin cell, a time resolution of better than 25~ps is obtained for $>$3 GeV of deposited energy. For a single cell of \pwo, a time resolution of better than 45~ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.

physics.ins-det

An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

physics.ins-det

Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider

The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeters should be chosen to reduce the effect of the BIB, while keeping good physics performance. Several requirements can be inferred: i) high granularity to reduce the overlap of BIB particles in the same calorimeter cell; ii) excellent timing (of the order of 100 ps) to reduce the out-of-time component of the BIB; iii) longitudinal segmentation to distinguish the signal showers from the fake showers produced by the BIB; iv) good energy resolution (less than 10%/sqrt(E)) to obtain good physics performance, as has been already demonstrated for conceptual particle flow calorimeters. Our proposal consists of a semi-homogeneous electromagnetic calorimeter based on Lead Fluoride Crystals (PbF2) readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs): the Crilin calorimeter. In this paper, the performances of the Crilin calorimeter in the Muon Collider framework for hadron jets reconstruction have been analyzed. We report the single components characterizations together with the development of a small-scale prototype, consisting of 2 layers of 3x3 crystals each.

physics.ins-det

Commissioning of the PADME experiment with a positron beam

The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target. This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.

physics.ins-det

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm

We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations

hep-ex

Paschen curve for a PCB trace in low vacuum

For one PCB trace region, where bare high voltage trace goes near GND pad, we estimated an electrical breakdown voltage in low vacuum using simplified geometrical model under some assumptions. Experimental measurement of Paschen curve for the PCB board considered was proceed in pressure range from 2x10-3 mbar to 25 mbar.

physics.ins-det

The Mu2e Calorimeter Final Technical Design Report

Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.

physics.ins-det