Searcharxiv⌕ Search

arXiv subjects

S. Chattopadhyay

Publications and source records attributed to S. Chattopadhyay.

288 records · Page 16Linked to original sources

Upsilon cross section in p+p collisions at sqrt(s) = 200 GeV

We report on a measurement of the Upsilon(1S+2S+3S) -> e+e- cross section at midrapidity in p+p collisions at sqrt(s)=200 GeV. We find the cross section to be 114 +/- 38 (stat.) +23,-24 (syst.) pb. Perturbative QCD calculations at next-to-leading order in the Color Evaporation Model are in agreement with our measurement, while calculations in the Color Singlet Model underestimate it by 2 sigma. Our result is consistent with the trend seen in world data as a function of the center-of-mass energy of the collision and extends the availability of Upsilon data to RHIC energies. The dielectron continuum in the invariant mass range near the Upsilon is also studied to obtain a combined cross section of Drell-Yan plus (b b-bar) -> e+e-.

nucl-ex↗

Band crossing in Shears band of $^{108}$Cd

The level lifetimes have been measured for a Shears band of $^{108}$Cd which exhibits bandcrossing. The observed level energies and B(M1) rates have been successfully described by a semi-classical geometric model based on shear mechanism. In this geometric model, the bandcrossing in Shears band has been described as the reopening of the angle between the blades of a shear.

nucl-ex↗

Controlled defects in ZnO by low energy Ar irradiation

We report interesting observations in 1.2 MeV Ar8+ ion irradiated ZnO which, to the best of our knowledge, have not been published earlier and will be useful for the scientific community engaged in research on ZnO. Irradiation with the initial fluence 1 X 10^15 ions/cm^2 changes the colour of the sample from white to orange while the highest irradiation fluence makes it dark reddish brown that appears as black. Such changes in colour can be correlated with the oxygen vacancy type defects. No significant change in the grain size of the irradiated samples, as revealed from the x-ray diffraction (XRD) line width broadening, has been observed. Increase of surface roughness due to sputtering is clearly visible in scanning electron micrographs (SEM) with highest fluence of irradiation. Room temperature Photoluminescence (PL) spectrum of the unirradiated sample shows intense ultra-violet (UV) emission (~ 3.27 eV) and less prominent defect level emissions (2-3 eV). The overall emission is largely quenched due to initial irradiation fluence. But with increasing fluence UV emission is enhanced along with prominent defect level emissions. Remarkably, the resistivity of the irradiated sample with highest fluence is reduced by four orders of magnitude compared to that of the unirradiated sample. This indicates increase of donor concentration as well as their mobility due to irradiation. Oxygen vacancies are deep donors in ZnO, but surely they influence the stability of the shallow donors (presumably zinc interstitial related) and vice versa. This is in conformity with recent theoretical calculations.

cond-mat.mtrl-sci↗

Pion Interferometry in Au+Au and Cu+Cu Collisions at $\sqrt{s_{\rm{NN}}}$ = 62.4 and 200 GeV

We present a systematic analysis of two-pion interferometry in Au+Au collisions at $\sqrt{s_{\rm{NN}}}$ = 62.4 GeV and Cu+Cu collisions at $\sqrt{s_{\rm{NN}}}$ = 62.4 and 200 GeV using the STAR detector at RHIC. The multiplicity and transverse momentum dependences of the extracted correlation lengths (radii) are studied. The scaling with charged particle multiplicity of the apparent system volume at final interaction is studied for the RHIC energy domain. The multiplicity scaling of the measured correlation radii is found to be independent of colliding system and collision energy.

nucl-ex↗

Performances of linseed oil-free bakelite RPC prototypes with cosmic ray muons

A comparative study has been performed on Resistive Plate Chambers (RPC) made of two different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon, tetrafluroethane and isobutane in 34:59:7 mixing ratio, are tested for the efficiency and the stability with cosmic rays. A particular grade of bakelite (P-120, NEMA LI-1989 Grade XXX), used for high voltage insulation in humid conditions, was found to give satisfactory performance with stable efficiency of > 96% continuously for more than 130 days. A thin coating of silicone fluid on the inner surfaces of the bakelite RPC is found to be necessary for operation of the detector.

physics.ins-det↗

Development of linseed oil-free bakelite resistive plate chambers

In this paper we would like to present a few characteristics of the Resistive Plate Chambers (RPC) made of a particular grade of bakelite paper laminates (P-120, NEMA LI-1989 Grade XXX), produced and commercially available in India. This particular grade is used for high voltage insulation in humid conditions. The chambers are tested with cosmic rays in the streamer mode using argon, tetrafluroethane and isobutane in 34:59:7 mixing ratio. In the first set of detectors made with such grade, a thin coating of silicone fluid on the inner surfaces of the bakelite was found to be necessary for operation of the detector. Those silicone coated RPCs were found to give satisfactory performance with stable efficiency of >90% continuously for a long period as reported earlier. Results of the crosstalk measurement of these silicone coated RPC will be presented in this paper. Very recently RPCs made with the same grade of bakelite but having better surface finish, are found to give equivalent performance even without any coating inside. Preliminary results of this type of RPCs are also being presented.

physics.ins-det↗

Study of timing properties of single gap high-resistive bakelite RPC

The time resolution for several single gap (2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive (bulk resistivity ~ 10^10 - 10^12 ohm cm), 2 mm thick matt finished bakelite paper laminates with silicone coating on the inner surfaces, has been measured. The time resolution for all the modules has been found to be ~ 2 ns at the plateau region.

physics.ins-det↗

Beam-Energy and System-Size Dependence of Dynamical Net Charge Fluctuations

We present measurements of net charge fluctuations in $Au + Au$ collisions at $\sqrt{s_{NN}} = $ 19.6, 62.4, 130, and 200 GeV, $Cu + Cu$ collisions at $\sqrt{s_{NN}} = $ 62.4, 200 GeV, and $p + p$ collisions at $\sqrt{s} = $ 200 GeV using the dynamical net charge fluctuations measure $ν_{+-{\rm,dyn}}$. We observe that the dynamical fluctuations are non-zero at all energies and exhibit a modest dependence on beam energy. A weak system size dependence is also observed. We examine the collision centrality dependence of the net charge fluctuations and find that dynamical net charge fluctuations violate $1/N_{ch}$ scaling, but display approximate $1/N_{part}$ scaling. We also study the azimuthal and rapidity dependence of the net charge correlation strength and observe strong dependence on the azimuthal angular range and pseudorapidity widths integrated to measure the correlation.

nucl-ex↗

Development of bakelite based Resistive Plate Chambers

A Comparative study has been performed on Resistive Plate Chambers made of different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon : tetrafluroethane : isobutane in 34:59:7 mixing ratio, are tested with cosmic rays for the efficiency and the stability with cosmic rays. A particular grade of bakelite (P-120, NEMA LI-1989 Grade XXX), used for high voltage insulation in humid conditions, was found to give satisfactory performance with stable efficiency of > 96% continuously for more than 110 days. A silicone treatment of the inner surfaces of the bakelite RPC is found to be necessary for operation of the detector.

nucl-ex↗

Real Time Global Tests of the ALICE High Level Trigger Data Transport Framework

The High Level Trigger (HLT) system of the ALICE experiment is an online event filter and trigger system designed for input bandwidths of up to 25 GB/s at event rates of up to 1 kHz. The system is designed as a scalable PC cluster, implementing several hundred nodes. The transport of data in the system is handled by an object-oriented data flow framework operating on the basis of the publisher-subscriber principle, being designed fully pipelined with lowest processing overhead and communication latency in the cluster. In this paper, we report the latest measurements where this framework has been operated on five different sites over a global north-south link extending more than 10,000 km, processing a ``real-time'' data flow.

physics.ins-det↗

Strange baryon resonance production in $\sqrt{s_{NN}} = 200$ GeV $p+p$ and $Au+Au$ collisions

We report the measurements of $Σ(1385)$ and $Λ(1520)$ production in $p+p$ and $Au+Au$ collisions at $\sqrt{s_{NN}} = 200$ GeV from the STAR collaboration. The yields and the $p_{T}$ spectra are presented and discussed in terms of chemical and thermal freeze-out conditions and compared to model predictions. Thermal and microscopic models do not adequately describe the yields of all the resonances produced in central $Au+Au$ collisions. Our results indicate that there may be a time-span between chemical and thermal freeze-out during which elastic hadronic interactions occur.

nucl-ex↗

Absence of M2 Retardation in $^{35}Cl$: Evidence for Stronger Isospin-Mixing Effects in A=35 Mirror Nuclei

The lifetime of the 3163 keV, 7/2$^-$ isomeric state in $^{35}Cl$ that decays by a stretched M2 transition to the $3/2^+$ ground state, has been re-measured using the Doppler Shift Attenuation Method, by gating on the 1185 keV transition which directly feeds this state. This eliminates the uncertainties in the measurement arising from the direct feedings from the continuum. A mean life of 0.6$^{+0.5}_{-0.2}$ ps has been obtained from the present work. This is considerably smaller than the adopted value 45.3(6) ps. Implication of this major reduction in the lifetime has been pointed out.

nucl-ex↗

The STAR Photon Multiplicity Detector

Details concerning the design, fabrication and performance of STAR Photon Multiplicity Detector (PMD) are presented. The PMD will cover the forward region, within the pseudorapidity range 2.3--3.5, behind the forward time projection chamber. It will measure the spatial distribution of photons in order to study collective flow, fluctuation and chiral symmetry restoration.

nucl-ex↗

A Honeycomb Proportional Counter for Photon Multiplicity Measurement in the ALICE Experiment

A honeycomb detector consisting of a matrix of 96 closely packed hexagonal cells, each working as a proportional counter with a wire readout, was fabricated and tested at the CERN PS. The cell depth and the radial dimensions of the cell were small, in the range of 5-10 mm. The appropriate cell design was arrived at using GARFIELD simulations. Two geometries are described illustrating the effect of field shaping. The charged particle detection efficiency and the preshower characteristics have been studied using pion and electron beams. Average charged particle detection efficiency was found to be 98%, which is almost uniform within the cell volume and also within the array. The preshower data show that the transverse size of the shower is in close agreement with the results of simulations for a range of energies and converter thicknesses.

nucl-ex↗

Codon Distributions in DNA

The codons, sixtyfour in number, are distributed over the coding parts of DNA sequences. The distribution function is the plot of frequency-versus-rank of the codons. These distributions are characterised by parameters that are almost universal, i.e., gene independent. There is but a small part that depends on the gene. We present the theory to calculate the universal (gene-independent) part. The part that is gene-specific, however, has undetermined overlaps and fluctuations.

physics.bio-ph↗

A Preshower Photon Multiplicity Detector for the WA98 Experiment

A high granularity preshower detector has been fabricated and installed in the WA98 Experiment at the CERN SPS for measuring the spatial distribution of photons produced in the forward region in lead ion induced interactions. Photons are counted by detecting the preshower signal in plastic scintillator pads placed behind a 3 radiation length thick lead converter and applying a threshold on the scintillator signal to reject the minimum ionizing particles. Techniques to improve the imaging of the fibre and performance of the detector in the high multiplicity environment of lead-lead collisions are described. Using Monte-Carlo simulation methods and test beam data of pi- and e- at various energies the photon counting efficiency is estimated to be 68% for central and 73% for peripheral Pb+Pb collisions.

hep-ex↗

Vlasov dynamics for fermions on phase space lattice

Within the framework of stochastic one-body approach a simulation procedure to study the Vlasov dynamics for fermi system on phase space lattice is presented. To deal with fermions on lattice, the phase cell occupancy factors are taken to be either 1 or 0 in accordance with the Pauli exclusion principle. This has significant implications. First, the dynamical evolution does not alter initial temperature of the system and secondly, at finite temperature, the proper statistical behaviour related to the fluctuations over the samples is ensured. This method is applied for two distinct cases viz. the monopole vibration of cold dilute nucleus and the evolution of ring shaped matter distribution at finite temperature in the presence of radial flow. In the latter case, fragment multiplicities are found to be depend on the flow velocity. To check the reliability of the present calculations simulations have been performed with different choices of the grid size.

nucl-th↗

Fluctuation dynamics and formation of exotic shape

To study the role of fluctuation in the collisional dynamics, Boltzmann- Langevin formalism is applied in a two dimensional scenario. The importance of collective flow towards the formation of hollow structure is exhibited in our simulation result. The observation of large clusters along the transverse direction indicates the non-equilibrium aspects of the fragmentation process in the late stage of the reaction.

nucl-th↗