SearcharxivSearch

arXiv subjects

S. Cipiccia

Publications and source records attributed to S. Cipiccia.

6 recordsLinked to original sources

Sampling requirements in near-field ptychography

Ptychography is a robust lensless form of microscopy routinely used for applications spanning life and physical sciences. The most common ptychography setup consists in using a detector to record diffraction patterns in the far-field. A near-field version has been more recently introduced, and its potential is yet to be fully exploited. In this work, the sampling requirements for near-field ptychography are analysed. Starting from the characterisation available in literature, the formalism of the fractional Fourier transform is used to generalise analytically the sampling conditions. The results harmonise the far- and near-field regimes and widen the applications of the technique with respect to the current knowledge. This study is supported by simulations and provides clear guidelines on how to optimise the setup and acquisition strategies for near-field ptychography experiments. The results are key to drive the translation of the technique towards low brilliance sources.

physics.app-ph

Characterisation of Laser Wakefield Acceleration Efficiency with Octave Spanning Near-IR Spectrum Measurements

We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximised at $19\pm3$\% by tuning of the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimisation of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.

physics.plasm-ph

Cycloidal-spiral sampling for three-modal x-ray CT flyscans with two-dimensional phase sensitivity

We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation, phase (refraction) and scattering properties can be measured from a single frame, providing three complementary contrast channels. Up to now, such setups required the sample to be stepped at each rotation angle to sample signals at an adequate rate, to prevent resolution losses, anisotropic resolution, and under-sampling artefacts. However, the need for stepping necessitated a step-and-shoot implementation, which is affected by motors overheads and increases the total scan time. By contrast, our proposed scheme, by which continuous horizontal and vertical translations of the sample are integrated with its rotation (leading to a "cycloidal-spiral" trajectory), is fully compatible with continuous scanning (flyscans). This leads to greatly reduced scan times while largely preserving image quality and isotropic resolution.

physics.med-ph

AWAKE, The Advanced Proton Driven Plasma Wakefield Acceleration Experiment at CERN

The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton beam bunches from the SPS. The first experiments will focus on the self-modulation instability of the long (rms ~12 cm) proton bunch in the plasma. These experiments are planned for the end of 2016. Later, in 2017/2018, low energy (~15 MeV) electrons will be externally injected to sample the wakefields and be accelerated beyond 1 GeV. The main goals of the experiment will be summarized. A summary of the AWAKE design and construction status will be presented.

physics.acc-ph

Path to AWAKE: Evolution of the concept

This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experimental design, where the critical issues that arose and their solutions are described. We conclude with the design of the experiment as it is being realized at CERN and some words on the future outlook. A summary of the AWAKE design and construction status as presented in this conference is given in [1].

physics.plasm-ph

Proton-driven plasma wakefield acceleration: a path to the future of high-energy particle physics

New acceleration technology is mandatory for the future elucidation of fundamental particles and their interactions. A promising approach is to exploit the properties of plasmas. Past research has focused on creating large-amplitude plasma waves by injecting an intense laser pulse or an electron bunch into the plasma. However, the maximum energy gain of electrons accelerated in a single plasma stage is limited by the energy of the driver. Proton bunches are the most promising drivers of wakefields to accelerate electrons to the TeV energy scale in a single stage. An experimental program at CERN -- the AWAKE experiment -- has been launched to study in detail the important physical processes and to demonstrate the power of proton-driven plasma wakefield acceleration. Here we review the physical principles and some experimental considerations for a future proton-driven plasma wakefield accelerator.

physics.acc-ph