SearcharxivSearch

arXiv subjects

S. Conforti

Publications and source records attributed to S. Conforti.

5 recordsLinked to original sources

Pulsating ultraluminous X-ray sources: modeling the thermal emission and polarization properties

Ultraluminous X-ray sources (ULXs) are enigmatic sources first discovered in the 1980s in external galaxies. They are characterized by their extraordinarily high X-ray luminosity, which often exceeds $10^{40}\, \rm{erg \; s^{-1}}$. Our study aims to obtain more information about pulsating ULXs (PULXs), first of all, their viewing geometry, since it affects almost all the observables, such as the flux, the pulsed fraction, the polarization degree (PD), and polarization angle (PA). We present a simplified model, which primarily describes the thermal emission from an accreting, highly magnetized neutron star, simulating the contributions of an accretion disk and an accretion envelope surrounding the star magnetosphere, both described by a multicolor blackbody. Numerical calculations are used to determine the flux, PD, and PA of the emitted radiation, considering various viewing geometries. The model predictions are then compared to the observed spectra of two PULXs, M51 ULX-7 and NGC 7793 P13. We identified the best fitting geometries for these sources, obtaining values of the pulsed fraction and the temperature at the inner radius of the disk compatible with those obtained from previous works. We also found that measuring the polarization observables can give considerable additional information on the source.

astro-ph.HE

Performance of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector

This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (transimpedance and voltage) were implemented and tested. The ASIC was characterised both alone and as a module when connected to a 5$\times$5-pad array of LGAD sensors. In calibration measurements, the ASIC operating alone was found to satisfy the technical requirements for the project, with similar performances for both preamplifier types. In particular, the jitter was found to be 15$\pm$1~ps (35$\pm$1~ps) for an injected charge of 10~fC (4~fC). A degradation in performance was observed when the ASIC was connected to the LGAD array. This is attributed to digital couplings at the entrance of the preamplifiers. When the ASIC is connected to the LGAD array, the lowest detectable charge increased from 1.5~fC to 3.4~fC. As a consequence, the jitter increased for an injected charge of 4~fC. Despite this increase, ALTIROC1 still satisfies the maximum jitter specification (below 65~ps) for the HGTD project. This coupling issue also affects the time over threshold measurements and the time-walk correction can only be performed with transimpedance preamplifiers. Beam test measurements with a pion beam at CERN were also undertaken to evaluate the performance of the module. The best time resolution obtained using only ALTIROC TDC data was 46.3$\pm$0.7~ps for a restricted time of arrival range where the coupling issue is minimized. The residual time-walk contribution is equal to 23~ps and is the dominant electronic noise contribution to the time resolution at 15~fC.

physics.ins-det

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

physics.ins-det

A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of 3x1x1 $m^3$ has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.

physics.ins-det

PMm2: large photomultipliers and innovative electronics for the next-generation neutrino experiments

The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a solution is presented here. The very large surface of photodetection is segmented in macro pixels made of 16 hemispherical (12 inches) photomultiplier tubes connected to an autonomous front-end which works on a triggerless data acquisition mode. The expected data transmission rate is 5 Mb/s per cable, which can be achieved with existing techniques. This architecture allows to reduce considerably the cost and facilitate the industrialization. This document presents the simulations and measurements which define the requirements for the photomultipliers and the electronics. A proto-type of front-end electronics was successfully tested with 16 photomultiplier tubes supplied by a single high voltage, validating the built-in gain adjustment and the calibration principle. The first tests and calculations on the photomultiplier glass led to the study of a new package optimized for a 10 bar pressure in order to sustain the high underwater pressure.

physics.ins-det