9 recordsLinked to original sources

Development of a High-Resolution, High-Dynamic-Range Charge Detector for Ion Beam Monitoring

We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a custom readout electronics, underwent extensive testing during HERD and AMS beam tests at CERN SPS facilities. Initial testing showcased the detector's exceptional performance, emphasizing both high resolution and a dynamic range capable of measuring nuclei with atomic numbers ranging from 1 to 80. The prototype's compatibility with fast, quasi real-time data analysis qualifies it as an ideal candidate for online applications. This article presents the results from the testing phase of the prototype, highlighting its capabilities and performance. Ongoing detector development, potential applications, and future developments aimed at enhancing the detector's functionality and versatility are also discussed.

physics.ins-det

Performance assessment of the HERD calorimeter with a photo-diode read-out system for high-energy electron beams

The measurement of cosmic rays at energies exceeding 100 TeV per nucleon is crucial for enhancing the understanding of high-energy particle propagation and acceleration models in the Galaxy. HERD is a space-borne calorimetric experiment that aims to extend the current direct measurements of cosmic rays to unexplored energies. The payload is scheduled to be installed on the Chinese Space Station in 2027. The primary peculiarity of the instrument is its capability to measure particles coming from all directions, with the main detector being a deep, homogeneous, 3D calorimeter. The active elements are read out using two independent systems: one based on wavelength shifter fibers coupled to CMOS cameras, and the other based on photo-diodes read-out with custom front-end electronics. A large calorimeter prototype was tested in 2023 during an extensive beam test campaign at CERN. In this paper, the performance of the calorimeter for high-energy electron beams, as obtained from the photo-diode system data, is presented. The prototype demonstrated excellent performance, e.g., an energy resolution better than 1% for electrons at 250 GeV. A comparison between beam test data and Monte Carlo simulation data is also presented.

physics.ins-det

Development of the photo-diode subsystem for the HERD calorimeter double-readout

The measurement of cosmic-ray individual spectra provides unique information regarding the origin and propagation of astro-particles. Due to the limited acceptance of current space experiments, protons and nuclei around the "knee" region ($\sim1\ PeV$) can only be observed by ground based experiments. Thanks to an innovative design, the High Energy cosmic-Radiation Detection (HERD) facility will allow direct observation up to this energy region: the instrument is mainly based on a 3D segmented, isotropic and homogeneous calorimeter which properly measures the energy of particles coming from each direction and it will be made of about 7500 LYSO cubic crystals. The read-out of the scintillation light is done with two independent systems: the first one based on wave-length shifting fibers coupled to Intensified scientific CMOS cameras, the second one is made of two photo-diodes with different active areas connected to a custom front-end electronics. This photo-diode system is designed to achieve a huge dynamic range, larger than $10^7$, while having a small power consumption, few mW per channel. Thanks to a good signal-to-noise ratio, the capability of a proper calibration, by using signals of both non-interacting and showering particles, is also guaranteed. In this paper, the current design and the performance obtained by several tests of the photo-diode read-out system are discussed.

physics.ins-det

Light yield non-proportionality of inorganic crystals and its effect on cosmic-ray measurements

The multi-TeV energy region of the cosmic-ray spectra has been recently explored by direct detection experiments that used calorimetric techniques to measure the energy of the cosmic particles. Interesting spectral features have been observed in both all-electron and nuclei spectra. However, the interpretation of the results is compromised by the disagreements between the data obtained from the various experiments, that are not reconcilable with the quoted experimental uncertainties. Understanding the reason for the discrepancy among the measurements is of fundamental importance in view of the forthcoming high-energy cosmic-ray experiments planned for space, as well as for the correct interpretation of the available results. The purpose of this work is to investigate the possibility that a systematic effect may derive from the non-proportionality of the light response of inorganic crystals, typically used in high-energy calorimetry due to their excellent energy-resolution performance. The main reason for the non-proportionality of the crystals is that scintillation light yield depends on ionisation density. Experimental data obtained with ion beams were used to characterize the light response of various scintillator materials. The obtained luminous efficiencies were used as input of a Monte Carlo simulation to perform a comparative study of the effect of the light-yield non-proportionality on the detection of high-energy electromagnetic and hadronic showers. The result of this study indicates that, if the calorimeter response is calibrated by using the energy deposit of minimum ionizing particles, the measured shower energy might be affected by a significant systematic shift, at the level of few percent, whose sign and magnitude depend specifically on the type of scintillator material used.

astro-ph.HE

The CaloCube calorimeter for high-energy cosmic-ray measurements in space: performance of a large-scale prototype

The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the totalmass of the apparatus, which is amongst the most important constraints for a space mission. CaloCube is an homogeneous calorimeter whose basic geometry is cubic and isotropic, obtained by filling the cubic volume with small cubic scintillating crystals. In this way it is possible to detect particles arriving from every direction in space, thus maximizing the acceptance. This design summarizes a three-year R&D activity, aiming to both optimize and study the full-scale performance of the calorimeter, in the perspective of a cosmic-ray space mission, and investigate a viable technical design by means of the construction of several sizable prototypes. A large scale prototype, made of a mesh of 5x5x18 CsI(Tl) crystals, has been constructed and tested on high-energy particle beams at CERN SPS accelerator. In this paper we describe the CaloCube design and present the results relative to the response of the large scale prototype to electrons.

physics.ins-det

Tracker-In-Calorimeter (TIC): a calorimetric approach to tracking gamma rays in space experiments

A multi-messenger, space-based cosmic ray detector for gamma rays and charged particles poses several design challenges due to the different instrumental requirements for the two kind of particles. Gamma-ray detection requires layers of high Z materials for photon conversion and a tracking device with a long lever arm to achieve the necessary angular resolution to separate point sources; on the contrary, charge measurements for atomic nuclei requires a thin detector in order to avoid unwanted fragmentation, and a shallow instrument so to maximize the geometric factor. In this paper, a novel tracking approach for gamma rays which tries to reconcile these two conflicting requirements is presented. The proposal is based on the Tracker-In-Calorimeter (TIC) design that relies on a highly-segmented calorimeter to track the incident gamma ray by sampling the lateral development of the electromagnetic shower at different depths. The effectiveness of this approach has been studied with Monte Carlo simulations and has been validated with test beam data of a detector prototype.

physics.ins-det

Measurement of energy flow, cross section and average inelasticity of forward neutrons produced in $\mathrm{\sqrt{s} = 13 TeV}$ proton-proton collisions with the LHCf Arm2 detector

In this paper, we report the measurement of the energy flow, the cross section and the average inelasticity of forward neutrons (+ antineutrons) produced in $\sqrt{s} = 13$ TeV proton-proton collisions. These quantities are obtained from the inclusive differential production cross section, measured using the LHCf Arm2 detector at the CERN Large Hadron Collider. The measurements are performed in six pseudorapidity regions: three of them ($\eta > 10.75$, $8.99 < \eta < 9.21$ and $8.80 < \eta < 8.99$), albeit with smaller acceptance and larger uncertainties, were already published in a previous work, whereas the remaining three ($10.06 < \eta < 10.75$, $9.65 < \eta < 10.06$ and $8.65 < \eta < 8.80$) are presented here for the first time. The analysis was carried out using a data set acquired in June 2015 with a corresponding integrated luminosity of $\mathrm{0.194~nb^{-1}}$. Comparing the experimental measurements with the expectations of several hadronic interaction models used to simulate cosmic ray air showers, none of these generators resulted to have a satisfactory agreement in all the phase space selected for the analysis. The inclusive differential production cross section for $\eta > 10.75$ is not reproduced by any model, whereas the results still indicate a significant but less serious deviation at lower pseudorapidities. Depending on the pseudorapidity region, the generators showing the best overall agreement with data are either SIBYLL 2.3 or EPOS-LHC. Furthermore, apart from the most forward region, the derived energy flow and cross section distributions are best reproduced by EPOS-LHC. Finally, even if none of the models describe the elasticity distribution in a satisfactory way, the extracted average inelasticity is consistent with the QGSJET II-04 value, while most of the other generators give values that lie just outside the experimental uncertainties.

hep-ex

Measurement of inclusive forward neutron production cross section in proton-proton collisions at $\mathrm{\sqrt{s} = 13~TeV}$ with the LHCf Arm2 detector

In this paper, we report the measurement relative to the production of forward neutrons in proton-proton collisions at $\mathrm{\sqrt{s} = 13~TeV}$ obtained using the LHCf Arm2 detector at the Large Hadron Collider. The results for the inclusive differential production cross section are presented as a function of energy in three different pseudorapidity regions: $\eta > 10.76$, $8.99 < \eta < 9.22$ and $8.81 < \eta < 8.99$. The analysis was performed using a data set acquired in June 2015 that corresponds to an integrated luminosity of $\mathrm{0.194~nb^{-1}}$. The measurements were compared with the predictions of several hadronic interaction models used to simulate air showers generated by Ultra High Energy Cosmic Rays. None of these generators showed good agreement with the data for all pseudorapidity intervals. For $\eta > 10.76$, no model is able to reproduce the observed peak structure at around $\mathrm{5~TeV}$ and all models underestimate the total production cross section: among them, QGSJET II-04 shows the smallest deficit with respect to data for the whole energy range. For $8.99 < \eta < 9.22$ and $8.81 < \eta < 8.99$, the models having the best overall agreement with data are SIBYLL 2.3 and EPOS-LHC, respectively: in particular, in both regions SIBYLL 2.3 is able to reproduce the observed peak structure at around $\mathrm{1.5-2.5~TeV}$.

hep-ex

CaloCube: a novel calorimeter for high-energy cosmic rays in space

In order to extend the direct observation of high-energy cosmic rays up to the PeV region, highly performing calorimeters with large geometrical acceptance and high energy resolution are required. Within the constraint of the total mass of the apparatus, crucial for a space mission, the calorimeters must be optimized with respect to their geometrical acceptance, granularity and absorption depth. CaloCube is a homogeneous calorimeter with cubic geometry, to maximise the acceptance being sensitive to particles from every direction in space; granularity is obtained by relying on small cubic scintillating crystals as active elements. Different scintillating materials have been studied. The crystal sizes and spacing among them have been optimized with respect to the energy resolution. A prototype, based on CsI(Tl) cubic crystals, has been constructed and tested with particle beams. Some results of tests with different beams at CERN are presented.

physics.ins-det