Searcharxiv⌕ Search

arXiv subjects

S. E. Lillie

Publications and source records attributed to S. E. Lillie.

7 recordsLinked to original sources

Improved current density and magnetisation reconstruction through vector magnetic field measurements

Stray magnetic fields contain significant information about the electronic and magnetic properties of condensed matter systems. For two-dimensional (2D) systems, stray field measurements can even allow full determination of the source quantity. For instance, a 2D map of the stray magnetic field can be uniquely transformed into the 2D current density that gave rise to the field and, under some conditions, into the equivalent 2D magnetisation. However, implementing these transformations typically requires truncation of the initial data and involves singularities that may introduce errors, artefacts, and amplify noise. Here we investigate the possibility of mitigating these issues through vector measurements. For each scenario (current reconstruction and magnetisation reconstruction) the different possible reconstruction pathways are analysed and their performances compared. In particular, we find that the simultaneous measurement of both in-plane components ($B_x$ and $B_y$) enables near-ideal reconstruction of the current density, without singularity or truncation artefacts, which constitutes a significant improvement over reconstruction based on a single component (e.g. $B_z$). On the other hand, for magnetisation reconstruction, a single measurement of the out-of-plane field ($B_z$) is generally the best choice, regardless of the magnetisation direction. We verify these findings experimentally using nitrogen-vacancy magnetometry in the case of a 2D current density and a 2D magnet with perpendicular magnetisation.

physics.app-ph↗

Apparent delocalisation of the current flow in metallic wires observed with diamond nitrogen-vacancy magnetometry

We report on a quantitative analysis of the magnetic field generated by a continuous current running in metallic micro-wires fabricated on an electrically insulating diamond substrate. A layer of nitrogen-vacancy (NV) centres engineered near the diamond surface is employed to obtain spatial maps of the vector magnetic field, by measuring Zeeman shifts through optically-detected magnetic resonance spectroscopy. The in-plane magnetic field (i.e. parallel to the diamond surface) is found to be significantly weaker than predicted, while the out-of-plane field also exhibits an unexpected modulation. We show that the measured magnetic field is incompatible with Ampere's circuital law or Gauss's law for magnetism when we assume that the current is confined to the metal, independent of the details of the current density. This result was reproduced in several diamond samples, with a measured deviation from Ampere's law by as much as 94(6)\%. To resolve this apparent magnetic anomaly, we introduce a generalised description whereby the current is allowed to flow both above the NV sensing layer (including in the metallic wire) and below the NV layer (i.e. in the diamond). Inversion of the Biot-Savart law within this two-channel description leads to a unique solution for the two current densities, which completely explains the data, is consistent with the laws of classical electrodynamics and indicates a total NV-measured current that closely matches the electrically-measured current. However, this description also leads to the surprising conclusion that in certain circumstances the majority of the current appears to flow in the diamond substrate rather than in the metallic wire, and to spread laterally in the diamond by several micrometres away from the wire. No electrical conduction was observed between nearby test wires, ruling out a conventional conductivity effect. [...]

cond-mat.mes-hall↗

Microscopic imaging of elastic deformation in diamond via in-situ stress tensor sensors

The precise measurement of mechanical stress at the nanoscale is of fundamental and technological importance. In principle, all six independent variables of the stress tensor, which describe the direction and magnitude of compression/tension and shear stress in a solid, can be exploited to tune or enhance the properties of materials and devices. However, existing techniques to probe the local stress are generally incapable of measuring the entire stress tensor. Here, we make use of an ensemble of atomic-sized in-situ strain sensors in diamond (nitrogen-vacancy defects) to achieve spatial mapping of the full stress tensor, with a sub-micrometer spatial resolution and a sensitivity of the order of 1 MPa (corresponding to a strain of less than $10^{-6}$). To illustrate the effectiveness and versatility of the technique, we apply it to a broad range of experimental situations, including mapping the elastic stress induced by localized implantation damage, nano-indents and scratches. In addition, we observe surprisingly large stress contributions from functional electronic devices fabricated on the diamond, and also demonstrate sensitivity to deformations of materials in contact with the diamond. Our technique could enable in-situ measurements of the mechanical response of diamond nanostructures under various stimuli, with potential applications in strain engineering for diamond-based quantum technologies and in nanomechanical sensing for on-chip mass spectroscopy.

cond-mat.mtrl-sci↗

Spatial mapping of band bending in semiconductor devices using in-situ quantum sensors

Band bending is a central concept in solid-state physics that arises from local variations in charge distribution especially near semiconductor interfaces and surfaces. Its precision measurement is vital in a variety of contexts from the optimisation of field effect transistors to the engineering of qubit devices with enhanced stability and coherence. Existing methods are surface sensitive and are unable to probe band bending at depth from surface or bulk charges related to crystal defects. Here we propose an in-situ method for probing band bending in a semiconductor device by imaging an array of atomic-sized quantum sensing defects to report on the local electric field. We implement the concept using the nitrogen-vacancy centre in diamond, and map the electric field at different depths under various surface terminations. We then fabricate a two-terminal device based on the conductive two-dimensional hole gas formed at a hydrogen-terminated diamond surface, and observe an unexpected spatial modulation of the electric field attributed to a complex interplay between charge injection and photo-ionisation effects. Our method opens the way to three-dimensional mapping of band bending in diamond and other semiconductors hosting suitable quantum sensors, combined with simultaneous imaging of charge transport in complex operating devices.

cond-mat.mtrl-sci↗

Magnetic noise from ultra-thin abrasively deposited materials on diamond

Sensing techniques based on the negatively charged nitrogen-vacancy (NV) centre in diamond have emerged as promising candidates to characterise ultra-thin and 2D materials. An outstanding challenge to this goal is isolating the contribution of 2D materials from undesired contributions arising from surface contamination, and changes to the diamond surface induced by the sample or transfer process. Here we report on such a scenario, in which the abrasive deposition of trace amounts of materials onto a diamond gives rise to a previously unreported source of magnetic noise. By deliberately scratching the diamond surface with macroscopic blocks of various metals (Fe, Cu, Cr, Au), we are able to form ultra-thin structures (i.e. with thicknesses down to $<1$\,nm), and find that these structures give rise to a broadband source of noise. Explanation for these effects are discussed, including spin and charge noise native to the sample and/or induced by sample-surface interactions, and indirect effects, where the deposited material affects the charge stability and magnetic environment of the sensing layer. This work illustrates the high sensitivity of NV noise spectroscopy to ultra-thin materials down to sub-nm regimes -- a key step towards the study of 2D electronic systems -- and highlights the need to passivate the diamond surface for future sensing applications in ultra-thin and 2D materials.

cond-mat.mes-hall↗

Proximity-induced artefacts in magnetic imaging with nitrogen-vacancy ensembles in diamond

Magnetic imaging with ensembles of nitrogen-vacancy (NV) centres in diamond is a recently developed technique that allows for quantitative vector field mapping. Here we uncover a source of artefacts in the measured magnetic field in situations where the magnetic sample is placed in close proximity (a few tens of nm) to the NV sensing layer. Using magnetic nanoparticles as a test sample, we find that the measured field deviates significantly from the calculated field, in shape, amplitude and even in sign. By modelling the full measurement process, we show that these discrepancies are caused by the limited measurement range of NV sensors combined with the finite spatial resolution of the optical readout. We numerically investigate the role of the stand-off distance to identify an artefact-free regime, and discuss an application to ultrathin materials. This work provides a guide to predict and mitigate proximity-induced artefacts that can arise in NV-based wide-field magnetic imaging, and also demonstrates that the sensitivity of these artefacts to the sample can make them a useful tool for magnetic characterisation.

cond-mat.mes-hall↗

Spin properties of dense near-surface ensembles of nitrogen-vacancy centres in diamond

We present a study of the spin properties of dense layers of near-surface nitrogen-vacancy (NV) centres in diamond created by nitrogen ion implantation. The optically detected magnetic resonance contrast and linewidth, spin coherence time, and spin relaxation time, are measured as a function of implantation energy, dose, annealing temperature and surface treatment. To track the presence of damage and surface-related spin defects, we perform in situ electron spin resonance spectroscopy through both double electron-electron resonance and cross-relaxation spectroscopy on the NV centres. We find that, for the energy ($4-30$~keV) and dose ($5\times10^{11}-10^{13}$~ions/cm$^2$) ranges considered, the NV spin properties are mainly governed by the dose via residual implantation-induced paramagnetic defects, but that the resulting magnetic sensitivity is essentially independent of both dose and energy. We then show that the magnetic sensitivity is significantly improved by high-temperature annealing at $\geq1100^\circ$C. Moreover, the spin properties are not significantly affected by oxygen annealing, apart from the spin relaxation time, which is dramatically decreased. Finally, the average NV depth is determined by nuclear magnetic resonance measurements, giving $\approx10$-17~nm at 4-6 keV implantation energy. This study sheds light on the optimal conditions to create dense layers of near-surface NV centres for high-sensitivity sensing and imaging applications.

cond-mat.mtrl-sci↗