SearcharxivSearch

arXiv subjects

S. Evseev

Publications and source records attributed to S. Evseev.

5 recordsLinked to original sources

First observation of single beta decay of $^{96}$Zr

The single beta decay of $^{96}$Zr has been detected for the first time using a 211 cm$^3$ low-background HPGe detector and an external source consisting of two samples of enriched zirconium (atomic fraction of $^{96}$Zr is 88.28%, total mass is 140.65 g). During the search for the $\beta$ decay of $^{96}$Zr, the $\beta$ decay of the daughter nucleus $^{96}$Nb to the excited states of $^{96}$Mo has been observed. The $\gamma$-ray cascade produced by the $^{96}$Mo nucleus while de-exciting to the ground state has been detected with the HPGe detector. The experiment has been carried out at the Baksan Neutrino Observatory. It has produced 12625.34 h of data. The half-life of the single beta decay of $^{96}$Zr is measured to be $T_{1/2} = [2.27^{+0.53}_{-0.36}(stat) \pm 0.27(syst)]\times10^{20}$ yr.

nucl-ex

First investigation of $^{96}$Zr samples enriched by the gas-centrifuge method for the use in rare-decay studies

For the first time, the isotope $^{96}$Zr has been produced by the gas-centrifuge method (enrichment is 88.28% and full mass of $^{96}$Zr is 179.816 g). The level of radionuclide impurities of the samples and thus their suitability for rare-event search have been investigated using three low-background HPGe detectors. The most stringent limit, obtained at sea level, on the half-life of the double beta decay of $^{96}$Zr to the $0^+_1$ excited state (1148 keV) of $^{96}$Mo has been set $T_{1/2}(0\nu+2\nu)>3.9 \times 10^{19}$ yr (90% C.L.).

nucl-ex

Application of a high-precision distributed uranium source for determining the effective mass and volume of a HPGe detector

A distributed uranium source with the accurately certified activity of 238U has been used to verify the effective mass of the HPGe detector intended for the {\nu}GeN neutrino experiment. The source, dissolved in nitric acid, provides homogeneous irradiation of the detector crystal allowing the study of its mass and volume. The experimental spectra obtained with the distributed source have been compared to the detailed Geant4 Monte Carlo simulations. The measured counting rates of several gamma-lines agree with the simulated efficiencies, confirming that the detector mass and volume coincide with the manufacturer specifications. The results demonstrate the applicability of such sources for mass calibration of HPGe detectors.

physics.ins-det

New constraints on coherent elastic neutrino-nucleus scattering by the nuGeN experiment

The nuGeN experiment searches for coherent elastic neutrino-nucleus scattering (CEvNS) at the Kalinin Nuclear Power Plant. A 1.41-kg high-purity low-threshold germanium detector surrounded by active and passive shielding is deployed at the minimal distance of 11.1 m allowed by the lifting mechanism from the center of reactor core, utilizing one of the highest antineutrino fluxes among the competing experiments. The direct comparison of the count rates obtained during reactor-ON and reactor-OFF periods with the energy threshold of 0.29~keV$_{ee}$ shows no statistically significant difference. New upper limits on the number of CEvNS events are evaluated on the basis of the residual ON$-$OFF count rate spectrum.

hep-ex

First results of the nuGeN experiment on coherent elastic neutrino-nucleus scattering

The nuGeN experiment is aimed to investigate neutrino properties using antineutrinos from the reactor of the Kalinin Nuclear Power Plant. The experimental setup is located at about 11 meters from the center of the 3.1 GWth reactor core. Scattering of the antineutrinos from the reactor is detected with low energy threshold high purity germanium detector. Passive and active shieldings are used to suppress all kinds of backgrounds coming from surrounding materials and cosmic radiation. The description of the experimental setup together with the first results is presented. The data taken in regimes with reactor ON (94.50 days) and reactor OFF (47.09 days) have been compared. No significant difference between spectra of two data sets is observed, i.e. no positive signals for coherent elastic neutrino-nucleus scattering are detected. Under Standard Model assumptions about coherent neutrino scattering an upper limit on a quenching parameter k < 0.26 (90 \% C.L.) in germanium has been set.

nucl-ex