SearcharxivSearch

arXiv subjects

S. Fratina

Publications and source records attributed to S. Fratina.

3 recordsLinked to original sources

Evidence for CP Violation in B0 -> D+D- Decays

We report measurements of the branching fraction and CP violation parameters in B0 -> D+D- decays. The results are based on a data sample that contains 535 x 10^6 BBbar pairs collected at the Upsilon(4S) resonance, with the Belle detector at the KEKB asymmetric-energy e+e- collider. We obtain [1.97 +- 0.20 (stat) +- 0.20 (syst)] x 10^(-4) for the branching fraction of B0 -> D+D-. The measured values of the CP violation parameters are: S = -1.13 +- 0.37 +- 0.09, A = 0.91 +- 0.23 +- 0.06, where the first error is statistical and the second is systematic. We find evidence of CP violation in B0 -> D+D- at the 4.1 sigma confidence level. While the value of S is consistent with expectations from other measurements, the value of the parameter A favors large direct CP violation at the 3.2 sigma confidence level, in contradiction to Standard Model expectations.

hep-ex

A novel type of proximity focusing RICH counter with multiple refractive index aerogel radiator

A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degradation in single photon angular resolution associated with the increased uncertainty of the emission point. With the refractive index of consecutive layers suitably increasing in the downstream direction, one may achieve overlapping of the Cherenkov rings from a single charged particle. In the opposite case of decreasing refractive index, one may obtain well separated rings. In the former combination an approximately 40% increase in photon yield is accompanied with just a minor degradation in single photon angular resolution. The impact of this improvement on the pion/kaon separation at the upgraded Belle detector is discussed.

physics.ins-det

Studies of Proximity Focusing RICH with an aerogel radiator using Flat-panel multi-anode PMTs (Hamamatsu H8500)

A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 GeV/c and 4 GeV/c. The typical angular resolution was around 14 mrad, and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4 sigma level at 4 GeV/c.

physics.ins-det