Searcharxiv⌕ Search

arXiv subjects

S. Gras

Publications and source records attributed to S. Gras.

24 records · Page 2Linked to original sources

Quantum correlation measurements in interferometric gravitational wave detectors

Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.

physics.optics↗

Audio-band Coating Thermal Noise Measurement for Advanced LIGO with a Multi-mode Optical Resonator

In modern high precision optical instruments, such as in gravitational wave detectors or frequency references, thermally induced fluctuations in the reflective coatings can be a limiting noise source. This noise, known as coating thermal noise, can be reduced by choosing materials with low mechanical loss. Examination of new materials becomes a necessity in order to further minimize the coating thermal noise and thus improve sensitivity of next generation instruments. We present a novel approach to directly measure coating thermal noise using a high finesse folded cavity in which multiple Hermite-Gaussian modes co-resonate. This method is used to probe surface fluctuations on the order 10^-17 m\rtHz in the frequency range 30-400 Hz. We applied this technique to measure thermal noise and loss angle of the coating used in Advanced LIGO.

physics.ins-det↗

Observation of the Three-Mode Parametric Instability

Three-mode parametric interactions occur in triply-resonant optomechanical systems: photons from an optical pump mode are coherently scattered to a high-order mode by mechanical motion of the cavity mirrors, and these modes resonantly interact via radiation pressure force when certain conditions are met. Such effects are predicted to occur in long baseline advanced gravitational-wave detectors. They can pump energy into acoustic modes, leading to parametric instability, but they can also extract acoustic energy, leading to optomechanical cooling. We develop a large amplitude model of three-mode interactions that explains the ring-up amplitude saturation after instability occurs. We also demonstrate both radiation-pressure cooling and mechanical amplification in two different three-mode optomechanical systems, including the first observation of the three-mode parametric instability in a free-space Fabry-Perot cavity. The experimental data agrees well with the theoretical model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques to overcome instability.

physics.optics↗

Three-mode opto-acoustic parametric interactions with coupled cavity

We theoretically analyze three-mode opto-acoustic parametric interactions in a coupled Fabry-Perot cavity, where one acoustic mode interacts with two optical modes. We show explicitly that extra degrees of freedom in a coupled cavity allow explorations of both parametric instability and cooling regimes with high parametric gain in a single table top experiment. This work can motivate experimental realizations of the three-mode parametric instability which might be an issue in next-generation gravitational-wave detectors with high optical-power cavities, helping in the development of better models, and in developing techniques for controls. In addition, we show that the same scheme can be implemented in the resolved-sideband acoustic-mode cooling.

physics.optics↗

Parametric instabilities and their control in advanced interferometer GW detectors

A detailed simulation of Advanced LIGO test mass optical cavities shows that parametric instabilities will excite acoustic modes in the test masses in the frequency range 28-35 kHz and 64-72 kHz. Using nominal Advanced LIGO optical cavity parameters with fused silica test masses, parametric instability excites 7 acoustic modes in each test mass, with parametric gain R up to 7. For the alternative sapphire test masses only 1 acoustic mode is excited in each test mass with R ~ 2. Fine tuning of the test mass radii of curvature cause the instabilities to sweep through various modes with R as high as ~2000. Sapphire test mass cavities can be tuned to completely eliminate instabilities using thermal g-factor tuning with negligible degradation of the noise performance. In the case of fused silica test mass, instabilities can be minimized but not eliminated.

gr-qc↗

LBQS 1429-0053: a binary quasar rather than a lensed quasar

Very deep ESO/VLT FORS1 and ISAAC images, as well as HST NICMOS2 data are used to infer the nature of the quasar pair LBQS 1429-0053 A and B, either a binary quasar or a doubly-imaged lensed quasar. Direct search of a putative lensing galaxy is unsuccessful . Moreover, no galaxy overdensity close to the quasar pair is found. A weak shear analysis of the field also fails at detecting any concentration of dark matter and weakens the hypothesis of a dark lens. The only sign of a possible lens consists in a group of 5 objects at z~1, within a radius of 5'', from the quasar pair. Considering this group as the lensing potential does not allow to reproduce the image position and flux ratio of the quasars. Our deep R-band image shows a blue, extended object at the position of quasar A, which is consistent with either being the lensed quasar A host, or being an intervening galaxy at lower redshift. Unless future very deep optical images demonstrate that this object is actually the lensed host of LBQS 1429-0053, we conclude that there is very little evidence for this quasar being lensed. Therefore, we are led to declare LBQS 1429-0053 A and B a genuine binary quasar.

astro-ph↗