SearcharxivSearch

arXiv subjects

S. Green

Publications and source records attributed to S. Green.

8 recordsLinked to original sources

Neutron spectroscopy with a high-pressure nitrogen-filled spherical proportional counter

The spherical proportional counter is a large volume gaseous detector which finds application in several fields, including direct Dark Matter searches. When the detector is filled with nitrogen it becomes an effective neutron spectrometer thanks to the $^{14}$N(n,$\mathrm{\alpha}$)$^{11}$B and $^{14}$N(n,p)$^{14}$C reactions. Nitrogen, however, is a challenging operating gas for proportional counters and requires a high electric field strength to gas pressure ratio. Benefiting from the latest advances in spherical proportional counter instrumentation and simulation techniques, we report first neutron measurements at operating pressures of up to 1.8 bar. This achievement enhances the prospects of the spherical proportional counter to act as a neutron spectrometer appropriate for challenging environments, including underground laboratories, and industrial and medical settings.

physics.ins-det

Thermal emission from bow shocks II: 3D magnetohydrodynamic models of Zeta Ophiuchi

The nearby, massive, runaway star Zeta Ophiuchi has a large bow shock detected in optical and infrared, and, uniquely among runaway O stars, diffuse X-ray emission is detected from the shocked stellar wind. Here we make the first detailed computational investigation of the bow shock of Zeta Ophiuchi, to test whether a simple model of the bow shock can explain the observed nebula, and to compare the detected X-ray emission with simulated emission maps. We re-analysed archival {\it Chandra} observations of the thermal diffuse X-ray emission from the shocked wind region of the bow shock, finding total unabsorbed X-ray flux (0.3-2 keV band) corresponding to a diffuse luminosity of $L_\mathrm{X}=2.33~(0.79-3.45)\times10^{29}$ergs$^{-1}$. 3D MHD simulations were used to model the interaction of the star's wind with a uniform ISM using a range of stellar and ISM parameters motivated by observational constraints. Synthetic infrared, Ha, soft X-ray, emission measure, and radio 6\,GHz emission maps were generated from three simulations, for comparison with relevant observations. Simulations where the space velocity of Zeta Ophiuchi has a significant radial velocity produce infrared emission maps with opening angle of the bow shock in better agreement with observations than for the case where motion is fully in the plane of the sky. The simulation with the highest pressure has the closest match, with flux level within a factor of 2 of the observational lower limit, and emission weighted temperature of $\log_{10}(T_\mathrm{A}/\mathrm{K})=6.4$, although the morphology of the diffuse emission appears somewhat different. Observed X-ray emission is a filled bubble brightest near the star whereas simulations predict brightening towards the contact discontinuity as density increases.

astro-ph.GA

Neutron spectroscopy with N$_2$-filled high-pressure large-volume spherical proportional counters

Precise in-situ measurements of the neutron flux in underground laboratories is crucial for direct dark matter searches, as neutron induced backgrounds can mimic the typical dark matter signal. The development of a novel neutron spectroscopy technique using Spherical Proportional Counters is investigated. The detector is operated with nitrogen and is sensitive to both fast and thermal neutrons through the $^{14}$N(n, $\alpha$)$^{11}$B and $^{14}$N(n, p)$^{14}$C reactions. This method holds potential to be a safe, inexpensive, effective, and reliable alternative to $^3$He-based detectors. Measurements of fast and thermal neutrons from an Am-Be source with a Spherical Proportional Counter operated at pressures up to 2 bar at Birmingham are discussed.

physics.ins-det

Tracking performance and simulation of capacitively coupled pixel detectors for the CLIC vertex detector

In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS process, capacitively coupled to hybrid pixel readout chips. Recent results have shown the approach to be feasible, though more detailed studies of the performance of such devices, including simulation, are required. The CLICdp collaboration has developed a number of ASICs as part of its vertex detector R&D programme, and here we present results on the performance of a CCPDv3 active sensor glued to a CLICpix readout chip. Charge collection characteristics and tracking performance have been measured over the full expected angular range of incident particles using 120 GeV/c secondary hadron beams from the CERN SPS. Single hit efficiencies have been observed above 99% in the full range of track incidence angles, down to shallow angles. The single hit resolution has also been observed to be stable over this range, with a resolution around 6 $\mu$m. The measured charge collection characterstics have been compared to simulations carried out using the Sentaurus TCAD finite-element simulation package combined with circuit simulations and parametrisations of the readout chip response. The simulations have also been successfully used to reproduce electric fields, depletion depths and the current-voltage characteristics of the device, and have been further used to make predictions about future device designs.

physics.ins-det

Top-Quark Physics at the CLIC Electron-Positron Linear Collider

The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy frontier, providing sensitivity to physics beyond the Standard Model (BSM) and precision measurements of Standard Model processes with an emphasis on Higgs boson and top-quark physics. The opportunities for top-quark physics at CLIC are discussed in this paper. The initial stage of operation focuses on top-quark pair production measurements, as well as the search for rare flavour-changing neutral current (FCNC) top-quark decays. It also includes a top-quark pair production threshold scan around 350 GeV which provides a precise measurement of the top-quark mass in a well-defined theoretical framework. At the higher-energy stages, studies are made of top-quark pairs produced in association with other particles. A study of ttH production including the extraction of the top Yukawa coupling is presented as well as a study of vector boson fusion (VBF) production, which gives direct access to high-energy electroweak interactions. Operation above 1 TeV leads to more highly collimated jet environments where dedicated methods are used to analyse the jet constituents. These techniques enable studies of the top-quark pair production, and hence the sensitivity to BSM physics, to be extended to higher energies. This paper also includes phenomenological interpretations that may be performed using the results from the extensive top-quark physics programme at CLIC.

hep-ex

Higgs Physics at the CLIC Electron-Positron Linear Collider

The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3 TeV. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (e+e- -> ZH) and WW-fusion (e+e- -> Hnunu), resulting in precise measurements of the production cross sections, the Higgs total decay width Gamma_H, and model-independent determinations of the Higgs couplings. Operation at sqrt(s) > 1 TeV provides high-statistics samples of Higgs bosons produced through WW-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes e+e- -> ttH and e+e- -> HHnunu allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.

hep-ex

THERMAP: a mid-infrared spectro-imager for space missions to small bodies in the inner solar system

We present THERMAP, a mid-infrared (8-16 μm) spectro-imager for space missions to small bodies in the inner solar system, developed in the framework of the MarcoPolo-R asteroid sample return mission. THERMAP is very well suited to characterize the surface thermal environment of a NEO and to map its surface composition. The instrument has two channels, one for imaging and one for spectroscopy: it is both a thermal camera with full 2D imaging capabilities and a slit spectrometer. THERMAP takes advantage of the recent technological developments of uncooled microbolometers detectors, sensitive in the mid-infrared spectral range. THERMAP can acquire thermal images (8-18 μm) of the surface and perform absolute temperature measurements with a precision better than 3.5 K above 200 K. THERMAP can acquire mid-infrared spectra (8-16 μm) of the surface with a spectral resolution Δλ of 0.3 μm. For surface temperatures above 350 K, spectra have a signal-to-noise ratio >60 in the spectral range 9-13 μm where most emission features occur.

astro-ph.IM

Heliophysics Event Knowledgebase for the Solar Dynamics Observatory and Beyond

The immense volume of data generated by the suite of instruments on SDO requires new tools for efficient identifying and accessing data that is most relevant to research investigations. We have developed the Heliophysics Events Knowledgebase (HEK) to fill this need. The HEK system combines automated data mining using feature-detection methods and high-performance visualization systems for data markup. In addition, web services and clients are provided for searching the resulting metadata, reviewing results, and efficiently accessing the data. We review these components and present examples of their use with SDO data.

astro-ph.IM